| Description | FluidX 1.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 1.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 48-well format SBS racks or bulk
- Sealable with screw caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent 2D code laser etched in high contrast on the tube base, a permanent 1D linear barcode and human-readable number laser etched in high-contrast on the tube side. All three codes are identical and auditing processes guarantee all three codes match; standard 2D coding option is black on white. ... Read More | 4titude polypropylene wells, polycarbonate frame, cut corners A24 and P24; working volume: <30μl, total well capacity: 55μl; designed for use on the Roche LightCycler® 480 with 384 well block. The dimensions of these plates are designed to achieve optimized assay conditions on the 4titude polypropylene wells, polycarbonate frame, cut corners A24 and P24; working volume: <30μl, total well capacity: 55μl; designed for use on the Roche LightCycler® 480 with 384 well block. The dimensions of these plates are designed to achieve optimized assay conditions on the Roche LightCycler® 480, and are in a 384 well format for reaction volumes of up to 30μl. The rigid two-component design eliminates warping and distortion during the PCR process, making it ideal for use with robotic systems. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <30μl working volume, 55μl total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with Roche LightCycler® 480
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Available as a clear polycarbonate frame with clear polypropylene wells
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request
- Combi packs available with qPCR Seal (4ti-0560)
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with ABI® Fast block thermal cyclers
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Standard plate comes with clear polypropylene wells with a clear polypropylene frame
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Also available as a clear frame with frosted wells for use with ABI®/LifeTechnologies® qPCR instruments
- Combi packs available (for 4ti-0910/C) with Optically Clear Windowed qPCR Seal (4ti-0565)
- Available barcoded upon request
... Read More | 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids handling when wearing gloves. The adhesive is contained within small capsules, allowing light to pass through to ensure the optical clarity of the seal. When the seal is in position, pressure can be applied to burst the capsules, releasing a strong adhesive only where the seal touches the raised well rims of the plate - the rest of the seal area above the wells remains optically clear. Key Features: - Non-pierceable
- Peelable
- Seal integrity range: -80°C to 110°C
- Free from DNase, RNase, and human genomic DNA
- Non-sterile
- Applications: qPCR and other fluorescent applications, plate readers, microscopy and protein crystallization (96 or 384 well)
- Removal: will not leave a sticky residue on the plate surface following removal
- Replacement for: ABI® MicroAmp Optical Adhesive film, Absolute qPCR plate seals and Roche LightCycler® sealing foils
- Sheet format: 140 x 77mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates with 96 round wells
- Roll format: 100m x 80mm, approx. 700 seals
... Read More | FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available
FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available empty or pre-filled with caps
Suitable for manual use or for use with Azenta Life Sciences Semi-Automated Screw Cap Decappers/Recappers, Single Channel and IntelliXcap™ Automated Screw Cap Decappers/Recappers. - Enable uncapped tubes to be used immediately and then capped using an automated capping and de-capping system
- When used manually, by transferring caps from the carrier to the tube using a single tube transfer device, the operation becomes faster and the risk of contamination is reduced as cap handling is eliminated
- Available in cases of 10 or 50, empty or pre-filled with low-retention screw caps that can reduce sample loss
... Read More |
| Applications | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | PCR, qPCR, NGS | PCR, qPCR, NGS | qPCR, Fluorescent Applications, Plate Readers, Microscopy Protein Crystallization (96 or 384 well) | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |