| Description | FluidX Cryo Storage Boxes / Racks are specifically aimed at users who have freezer racking set up for Cryo Freeze Boxes, wanting to store sample storage tubes such as the Azenta Life Sciences 1ml and 1.9ml Tri-Coded Sample Tubes. Designed to fit in freezer racking set up for Cryo Freeze Boxes, the FluidX Cryo Storage Boxes / Racks are specifically aimed at users who have freezer racking set up for Cryo Freeze Boxes, wanting to store sample storage tubes such as the Azenta Life Sciences 1ml and 1.9ml Tri-Coded Sample Tubes. Designed to fit in freezer racking set up for Cryo Freeze Boxes, the 9x9, 10x10, and 14x14 Cryo Racks enable ease of access to samples with an open bottom to allow 2D code reading on the Azenta Life Sciences Full Rack Readers. The Cryo Boxes are compatible with a broad range of tube formats, allowing you to store legacy collections and maintain ease of access to your valuable samples. - Available in 9x9, 10x10 and 14x14 array
- Cryo racks can be supplied with a unique 2D barcode identifier which can be read at the same time as the tube 2D barcode, to provide more secure sample tracking
- Open bottom for 2D barcode decoding on Azenta Life Sciences Readers
- Compatible with a number of tubes from Azenta as well as other manufacturers
- Unique identifier on every freeze box, in 1D & 2D format
- Optimizes storage space by increasing sample density
... Read More | 4titude 190μl square wells, V shaped bases, clear polypropylene. This plate is designed for high density sample collection and storage, for a wide array of applications within cell biology, molecular biology and drug discovery. The V shaped wells allow for complete sample retention with 4titude 190μl square wells, V shaped bases, clear polypropylene. This plate is designed for high density sample collection and storage, for a wide array of applications within cell biology, molecular biology and drug discovery. The V shaped wells allow for complete sample retention with pipettes, and are ultra-flat for a completely uniform seal, either with adhesive or heat seals, or with our accompanying silicone sealing mat (4ti-0139). Our plates are manufactured in cleanroom facilities which are certified free of RNase, DNase, human genomic DNA and endotoxins. We use only the highest medical grade virgin polypropylene with high resistance against chemicals such as DMSO, phenol, and chloroform. Key Features: - Made from polypropylene, a material with very low biomolecular binding characteristics, a high temperature tolerance and resistance to many standard laboratory chemicals, including DMSO
- Autoclavable
- Free from DNase, RNase, human genomic DNA, and endotoxin
- Conical V-bottoms
- Square wells, to make the best use of space, and to improve mixing
- Alphanumeric grid reference to aid well and sample identification
- SBS footprint
- Clear plate, perfect for storage applications
- Temperature range for use: -80°C to 120°C
- Best for precipitation, centrifugation and small volume recovery due to the conical V bottom, as the liquid gathers at the lowest point of the V for easy pipetting
- Stackable
- Suitable for adhesive and heat sealing
- Non-sterile as standard, sterilization available upon request; contact an expert for details and pricing
- Available barcoded upon request
- A clear silicone sealing mat (4ti-0139) is also available to fit this product, with 384 sections to correspond with the wells of this plate
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at H1
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request
- Similar plate with a cut corner at A12 for use with ABI® thermal cyclers and sequencers available: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12, working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block); extra white wells for improved sensitivity in fluorescent assays. Our 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12, working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block); extra white wells for improved sensitivity in fluorescent assays. Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100μl. The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The extra white wells allow for increased sensitivity in fluorescent assays. The semi-skirted frame allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with the Roche LightCycler® 96 and 480 (with 96 well block)
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Plates are available with a clear polycarbonate frame and extra white wells for improved sensitivity when using fluorescent based assays
- Combi packs available with qPCR Seal (4ti-0560)
- Available barcoded upon request
... Read More | CoolBox Ice-Free Cooling Workstation systems are bench top cooling workstations that provide sample cooling or freezing without ice, electricity or batteries. Ice-Free Cooling Workstation systems are versatile and accommodate a variety of sample formats and temperatures. The modular design enables CoolBox Ice-Free Cooling Workstation systems are bench top cooling workstations that provide sample cooling or freezing without ice, electricity or batteries. Ice-Free Cooling Workstation systems are versatile and accommodate a variety of sample formats and temperatures. The modular design enables the use of Thermoconductive Rack thermo-conductive sample modules to hold microfuge tubes, cryogenic vials, PCR tubes or plates, and more. Available in single or double capacity. - Ice-free cooling/freezing systems with lid or as open platform
- Fits a choice of Thermoconductive Rack modules
- Small footprint ideal for use in the hood especially in keeping temperature sensitive solutions cold
- CoolBox with lid keeps samples cold for up to 16 hours
- CoolBox with lid keeps samples frozen for up to 8 hours
- Open platform keeps samples cold for up to 4 hours
- The built-in 1-8ºC temperature indicator provides visual assurance of operational temperature while working
... Read More |
| Applications | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | Storage Applications, Collection Plate, Cell Biology Research, Molecular Biology Research, Drug Discovery, NGS | PCR, qPCR, NGS | PCR, qPCR, NGS | Ideal for use in any application where samples need to remain cold or frozen, suitable for use in hoods |