| Catalog Number | TruCool™ Hinged CryoBoxes | 4ti-0710, 4ti-0710/B, 4ti-0710/C, 4ti-0710/G, 4ti-0710/R, 4ti-0711 | 4ti-0960, 4ti-0960/B, 4ti-0960/C, 4ti-0960/G, 4ti-0960/R, 4ti-0960/X, 4ti-0960/W, 4ti-0961, 4ti-0961/C, 4ti-0966, 4ti-OX960C/SBC, 4ti-0960/RIG, 4ti-LB0960/RIG | 66-62317 / 66-62317-L / 66-62318 / 66-62318-Y6 / 66-62319 / 66-62319-L / 66-62319-Y6 / 66-62319-Y6-L | 66-62321 / 66-62321-L / 66-62330 / 66-62330-L / 66-62330-Y6 / 66-62330-Y6-L / 66-62345 / 66-62345-Y6 |
| Description | Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Feature plastic, adjustable slats that can be moved to accommodate multiple vial sizes. Recommended for use at room temperature, 4°C, -20°C and -80°C. - Lid fastened to the base
- Easy to close/open even when frozen and minimized contamination risk due to patented hinged lid
- Plastic dividers for protection during exposure
- Laminated fiberboard for durability and water resistance
- Grid numbers listed on top, inside and bottom for better tracking
- Different color options for easier tracking
- Recommended for use from room temperature to -80°C
- Hinged CryoBox with Drain Holes suitable at vapor phase LN2
- Adjustable slats can be moved to accommodate multiple vial sizes
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, meaning seal integrity is not compromised and less of your sample is lost through evaporation. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Also available as a black frame with white wells for optimum signal-to-noise ratio when using fluorescent based assays
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Ethylene oxide treated option available (4ti-OX960C/SBC) for forensic use
- Ultra-low DNA binding option available (4ti-LB0960/RIG) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
- Clear Polystyrene Lid (4ti-0287) available for 4ti-0960/RIG
... Read More | FluidX 0.7ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.7ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent laser etched 2D code and human readable number on tube base, allowing compatibility with low throughput manual, semi-automated or fully automated workflows on integrated platforms. Both codes are identical and auditing processes guarantee both codes match; standard 2D coding option is white on black. ... Read More | FluidX 0.9ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.9ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent laser etched 2D code and human readable number on tube base, allowing compatibility with low throughput manual, semi-automated or fully automated workflows on integrated platforms. Both codes are identical and auditing processes guarantee both codes match; standard 2D coding option is white on black. ... Read More |
| Applications | Recommended for sample storage at room temperature, 4°C, -20°C and -80°C | PCR, qPCR, NGS | PCR, qPCR, NGS | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |