| Catalog Number | TruCool™ Hinged CryoBoxes | 4ti-0540, 4ti-0540/80, 4ti-0540/REMP, 4ti-0540/S, 4ti-0542, 4ti-0542/REMP, 4ti-0542/S, 4ti-0541 | 4ti-0960, 4ti-0960/B, 4ti-0960/C, 4ti-0960/G, 4ti-0960/R, 4ti-0960/X, 4ti-0960/W, 4ti-0961, 4ti-0961/C, 4ti-0966, 4ti-OX960C/SBC, 4ti-0960/RIG, 4ti-LB0960/RIG | 66-62321 / 66-62321-L / 66-62330 / 66-62330-L / 66-62330-Y6 / 66-62330-Y6-L / 66-62345 / 66-62345-Y6 | 65-7650 / 65-7651 / 65-7652 / 65-7653 |
| Description | Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Feature plastic, adjustable slats that can be moved to accommodate multiple vial sizes. Recommended for use at room temperature, 4°C, -20°C and -80°C. - Lid fastened to the base
- Easy to close/open even when frozen and minimized contamination risk due to patented hinged lid
- Plastic dividers for protection during exposure
- Laminated fiberboard for durability and water resistance
- Grid numbers listed on top, inside and bottom for better tracking
- Different color options for easier tracking
- Recommended for use from room temperature to -80°C
- Hinged CryoBox with Drain Holes suitable at vapor phase LN2
- Adjustable slats can be moved to accommodate multiple vial sizes
... Read More | 4titude peelable heat sealing film, optically clear; suitable for qPCR and optical applications Heat sealing offers a 100% effective method for plate sealing for a complete seal integrity, as well as being quick and cost effective. Our Clear Heat Seal is an optically clear laminate film forming a 4titude peelable heat sealing film, optically clear; suitable for qPCR and optical applications Heat sealing offers a 100% effective method for plate sealing for a complete seal integrity, as well as being quick and cost effective. Our Clear Heat Seal is an optically clear laminate film forming a peelable seal to polypropylene, polyethylene, polystyrene, polycarbonate and cyclic olefin copolymer (COC) plates. Samples can also be accessed by pre-piercing with a blade, needle or our Pierce Plate (4ti-0398). The optical clarity of this seal enables its use for sealing plates required for imaging use, including fluorescent detection methods such as qPCR and colorimetric assays. The Clear Heat Seal forms a complete seal to a plate enabling both low temperature uses, including low temperature storage, and high temperature uses, such as PCR (when used with a pressurized heated lid). This seal demonstrates moderate solvent resistance and can be utilized for short term compound storage at room temperature. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Our sheet seals are inter-leaved with paper sheets to help denote which side is the sealing side and aid removal of one sheet at a time from the pack. For applications requiring high tensile strength (e.g. bead mill applications) please see ourClear Heat Seal Plus. Key Features: - Peelable
- Seal integrity range: -80°C to 80°C (to 110°C with a pressurized heated PCR lid)
- Optically clear
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Applications: imaging, fluorescent detection, and colorimetric assays
- Suitable for PCR and qPCR
- Seals polypropylene, polyethylene, polystyrene, polycarbonate and cyclic olefin copolymer (COC) plates
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Non-sterile as standard; sterilization available upon request
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Ethylene oxide treated option available (4ti-OX960C/SBC) for forensic use
- Ultra-low DNA binding option available (4ti-LB0960/RIG) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
- Clear Polystyrene Lid (4ti-0287) available for 4ti-0960/RIG
... Read More | FluidX 0.9ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.9ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent laser etched 2D code and human readable number on tube base, allowing compatibility with low throughput manual, semi-automated or fully automated workflows on integrated platforms. Both codes are identical and auditing processes guarantee both codes match; standard 2D coding option is white on black. ... Read More | Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample retrieval, therefore creating a reduction in reagent wastage resulting in cost savings. Azenta Life Sciences tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. - Unique design with combined ?v? and ?u? shaped bottom
- Sample identification from 1D, 2D and human readable code
- Capability to work with automation, designed for liquid handlers
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 48-well format SBS racks or bulk
Suitable for use with liquid handling automation, whether reformatting, cherry picking, aliquoting an/or normalization. The 1.6ml Maximum Recovery tube offers unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. ... Read More |
| Applications | Recommended for sample storage at room temperature, 4°C, -20°C and -80°C | PCR, qPCR, Imaging, Fluorescent Detection, Colorimetric Assays | PCR, qPCR, NGS | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | (For research use only) Liquid Handling workflows, Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |