| Catalog Number | 4ti-0960, 4ti-0960/B, 4ti-0960/C, 4ti-0960/G, 4ti-0960/R, 4ti-0960/X, 4ti-0960/W, 4ti-0961, 4ti-0961/C, 4ti-0966, 4ti-OX960C/SBC, 4ti-0960/RIG, 4ti-LB0960/RIG | 4ti-0730, 4ti-0730/B, 4ti-0730/C, 4ti-0730/C/10P, 4ti-0730/G, 4ti-0730/R, 4ti-0730/X, 4ti-OX730C/SBC | 4ti-0560, 4ti-0561, 4ti-0561/S | 65-7640 / 65-7641 / 65-7642 / 65-7643 | Thermoconductive Tube Racks |
| Description | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Ethylene oxide treated option available (4ti-OX960C/SBC) for forensic use
- Ultra-low DNA binding option available (4ti-LB0960/RIG) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
- Clear Polystyrene Lid (4ti-0287) available for 4ti-0960/RIG
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame with upstand, cut corner A12, working volume: <200μl, total well capacity: 300μl; designed for use on ABI® instruments. This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame with upstand, cut corner A12, working volume: <200μl, total well capacity: 300μl; designed for use on ABI® instruments. This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time quantitative PCR (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Ideal for use with ABI® thermal cyclers & sequencers
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, and black
- Ethylene oxide treated option available for forensic use
- Available barcoded upon request
- Combi packs available (for 4ti-0730/C) with Optically Clear Windowed qPCR Seal (4ti-0565)
... Read More | 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids handling when wearing gloves. The adhesive is contained within small capsules, allowing light to pass through to ensure the optical clarity of the seal. When the seal is in position, pressure can be applied to burst the capsules, releasing a strong adhesive only where the seal touches the raised well rims of the plate - the rest of the seal area above the wells remains optically clear. Key Features: - Non-pierceable
- Peelable
- Seal integrity range: -80°C to 110°C
- Free from DNase, RNase, and human genomic DNA
- Non-sterile
- Applications: qPCR and other fluorescent applications, plate readers, microscopy and protein crystallization (96 or 384 well)
- Removal: will not leave a sticky residue on the plate surface following removal
- Replacement for: ABI® MicroAmp Optical Adhesive film, Absolute qPCR plate seals and Roche LightCycler® sealing foils
- Sheet format: 140 x 77mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates with 96 round wells
- Roll format: 100m x 80mm, approx. 700 seals
... Read More | FluidX 1.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 1.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 48-well format SBS racks or bulk
- Sealable with screw caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent 2D code laser etched in high contrast on the tube base, a permanent 1D linear barcode and human-readable number laser etched in high-contrast on the tube side. All three codes are identical and auditing processes guarantee all three codes match; standard 2D coding option is black on white. ... Read More | Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which originate from tubes placed directly into ice, dry ice, alcohol baths, water baths and other temperature sources. - Ideal for cooling, snap freezing, heating or thawing
- Helps keep samples organized and dry
- All tubes upright and indexed
- Reproducible method
- Removes all problems created by placing sample directly in ice: variable sample temperature, wet labels, contamination risk
On ice - Adapts from ambient (25°C) to <4°c in="" 60-90="">4°c>
- Samples and labels stay dry
- Hours of ice cooling without direct ice contact
On dry ice - Adapts from ambient (25°C) to -78°C in approximately 5-7 minutes*
- Eliminates ethanol from snap freezing
- Equal or better freezing rate as compared to direct immersion into dry ice or alcohol slurry
In liquid nitrogen - Adapts from ambient (25°C) to approximately -150°C in approximately 12-14 minutes*
- Vapor barrier protects from ambient air
- No direct contact between samples and LN2
Heat sources - Use with water baths, hot plates, incubators and other heat sources to keep samples warm
*Average cooling rate from room temperature How it Works: Ease of Use: - Thermoconductive Tube Rack on ice: heat from the relatively warmer Thermoconductive Tube Rack module is transferred to cooling source (wet or dry ice, cartridge, LN2) until equilibrium is reached
- Thermoconductive Tube Rack in water bath: heat is transferred from water bath toward relatively cooler Thermoconductive Tube Rack until equilibrium is reached
... Read More |
| Applications | PCR, qPCR, NGS | PCR, qPCR, NGS | qPCR, Fluorescent Applications, Plate Readers, Microscopy Protein Crystallization (96 or 384 well) | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | Suggested applications include cooling reagents such as restriction enzymes, dNTPs and antibodies, alcohol-free dry ice snap freezing of tissue, virus and bacteria samples and bench top cryogenic tube sorting in liquid nitrogen |