| Catalog Number | 4ti-0730, 4ti-0730/B, 4ti-0730/C, 4ti-0730/C/10P, 4ti-0730/G, 4ti-0730/R, 4ti-0730/X, 4ti-OX730C/SBC | 4ti-0710, 4ti-0710/B, 4ti-0710/C, 4ti-0710/G, 4ti-0710/R, 4ti-0711 | 4ti-0910/C, 4ti-0910/C/10P, 4ti-0911, 4ti-0912, 4ti-0912/10P | 4ti-0531/RA | 67-63111-10 / 67-63111-50 / 68-53111-10N / 68-53111-50N / 68-53111-50X |
| Description | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame with upstand, cut corner A12, working volume: <200μl, total well capacity: 300μl; designed for use on ABI® instruments. This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame with upstand, cut corner A12, working volume: <200μl, total well capacity: 300μl; designed for use on ABI® instruments. This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time quantitative PCR (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Ideal for use with ABI® thermal cyclers & sequencers
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, and black
- Ethylene oxide treated option available for forensic use
- Available barcoded upon request
- Combi packs available (for 4ti-0730/C) with Optically Clear Windowed qPCR Seal (4ti-0565)
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, meaning seal integrity is not compromised and less of your sample is lost through evaporation. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Also available as a black frame with white wells for optimum signal-to-noise ratio when using fluorescent based assays
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with ABI® Fast block thermal cyclers
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Standard plate comes with clear polypropylene wells with a clear polypropylene frame
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Also available as a clear frame with frosted wells for use with ABI®/LifeTechnologies® qPCR instruments
- Combi packs available (for 4ti-0910/C) with Optically Clear Windowed qPCR Seal (4ti-0565)
- Available barcoded upon request
... Read More | 4titude pierceable heat sealing foil, 96 individual seals in sheet format, high solvent resistance, resealable; suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Individual Access 4titude pierceable heat sealing foil, 96 individual seals in sheet format, high solvent resistance, resealable; suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Individual Access Pierce Heat Seal is compatible with polypropylene and polystyrene plates, featuring 96 individual foil seal spots on a removable backing. This seal demonstrates good solvent resistance and can be used for low temperature and room temperature compound storage in DMSO and organic solvents. These seals result in individually sealed tubes, and they can be pierced with a pipette tip manually, or by a liquid handling robot. Individual Access Pierce Heat Seal can be resealed by applying another Individual Access Pierce Seal straight on top of a previously pierced seal. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Key Features: - 96 individual foil seal spots on a removable backing
- Pierceable
- 4 pin holes for exact positioning in special adapters of the Semi-Automated Sheet Heat Sealer
- Resealable
- Seal integrity range: -20°C to 120°C
- Good solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Seals polypropylene and polystyrene plates
- Suitable for long term storage
- Best used in combination with our Individual Access plates
- Sheet format: 127 x 100mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates
- Non-sterile as standard; sterilization available upon request
... Read More | FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available
FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available empty or pre-filled with caps
Suitable for manual use or for use with Azenta Life Sciences Semi-Automated Screw Cap Decappers/Recappers, Single Channel and IntelliXcap™ Automated Screw Cap Decappers/Recappers. - Enable uncapped tubes to be used immediately and then capped using an automated capping and de-capping system
- When used manually, by transferring caps from the carrier to the tube using a single tube transfer device, the operation becomes faster and the risk of contamination is reduced as cap handling is eliminated
- Available in cases of 10 or 50, empty or pre-filled with low-retention screw caps that can reduce sample loss
... Read More |