| Description | 4titude polypropylene wells, polycarbonate frame, cut corner A24; working volume: <30μl, total well capacity: 55μl; designed for use on standard thermal cyclers. Our FrameStar 384 Well Skirted PCR Plates are designed for high-throughput PCR. They are compatible with the majority of 384 4titude polypropylene wells, polycarbonate frame, cut corner A24; working volume: <30μl, total well capacity: 55μl; designed for use on standard thermal cyclers. Our FrameStar 384 Well Skirted PCR Plates are designed for high-throughput PCR. They are compatible with the majority of 384 well block PCR, qPCR and sequencing instruments. The rigid 2-component design eliminates warping and distortion during PCR making it ideal for use with robotic systems. The skirt allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <30μl working volume, 55μl total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of the frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Ultra-low DNA binding option available (4ti-LB0147) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
... Read More | 4titude ultra-clear base imaging microplate. The main advantage of using Ultra Optically Clear Plates is in the optically ultra-clear base of the plate, which gives superior results by delivering low absorbance and high transmission, together with low background signals. Not only this, but due to 4titude ultra-clear base imaging microplate. The main advantage of using Ultra Optically Clear Plates is in the optically ultra-clear base of the plate, which gives superior results by delivering low absorbance and high transmission, together with low background signals. Not only this, but due to its incredible optical clarity, the ultra-clear base of these plates delivers improved transmission of signals at low wavelengths compared to standard optical films. It allows DNA measurements at 260/280nm wavelengths in a medium or high throughput. Key Features: - Free from DNase, RNase and human genomic DNA
- Ultra-clear base improves transmission for low wavelengths
- Optimum signal-to-noise ratios
- Alphanumeric grid reference to aid well and sample identification
- Suitable for adhesive and heat sealing
- Available barcoded upon request
- Lid available (4ti-0290)
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at H1
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request
- Similar plate with a cut corner at A12 for use with ABI® thermal cyclers and sequencers available: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style
... Read More | 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids handling when wearing gloves. The adhesive is contained within small capsules, allowing light to pass through to ensure the optical clarity of the seal. When the seal is in position, pressure can be applied to burst the capsules, releasing a strong adhesive only where the seal touches the raised well rims of the plate - the rest of the seal area above the wells remains optically clear. Key Features: - Non-pierceable
- Peelable
- Seal integrity range: -80°C to 110°C
- Free from DNase, RNase, and human genomic DNA
- Non-sterile
- Applications: qPCR and other fluorescent applications, plate readers, microscopy and protein crystallization (96 or 384 well)
- Removal: will not leave a sticky residue on the plate surface following removal
- Replacement for: ABI® MicroAmp Optical Adhesive film, Absolute qPCR plate seals and Roche LightCycler® sealing foils
- Sheet format: 140 x 77mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates with 96 round wells
- Roll format: 100m x 80mm, approx. 700 seals
... Read More | Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which originate from tubes placed directly into ice, dry ice, alcohol baths, water baths and other temperature sources. - Ideal for cooling, snap freezing, heating or thawing
- Helps keep samples organized and dry
- All tubes upright and indexed
- Reproducible method
- Removes all problems created by placing sample directly in ice: variable sample temperature, wet labels, contamination risk
On ice - Adapts from ambient (25°C) to <4°c in="" 60-90="">4°c>
- Samples and labels stay dry
- Hours of ice cooling without direct ice contact
On dry ice - Adapts from ambient (25°C) to -78°C in approximately 5-7 minutes*
- Eliminates ethanol from snap freezing
- Equal or better freezing rate as compared to direct immersion into dry ice or alcohol slurry
In liquid nitrogen - Adapts from ambient (25°C) to approximately -150°C in approximately 12-14 minutes*
- Vapor barrier protects from ambient air
- No direct contact between samples and LN2
Heat sources - Use with water baths, hot plates, incubators and other heat sources to keep samples warm
*Average cooling rate from room temperature How it Works: Ease of Use: - Thermoconductive Tube Rack on ice: heat from the relatively warmer Thermoconductive Tube Rack module is transferred to cooling source (wet or dry ice, cartridge, LN2) until equilibrium is reached
- Thermoconductive Tube Rack in water bath: heat is transferred from water bath toward relatively cooler Thermoconductive Tube Rack until equilibrium is reached