| Catalog Number | 4ti-0770, 4ti-0770/B, 4ti-0770/C, 4ti-0770/C/10P, 4ti-0770/G, 4ti-0770/R, 4ti-0770/X, 4ti-0771, 4ti-0772, 4ti-0772/10P, 4ti-OX770C/SBC, 4ti-LB0770/C | 4ti-0900/C, 4ti-0901 | 4ti-1000/P, 4ti-1000/B, 4ti-1000/C, 4ti-1000/G, 4ti-1000/R, 4ti-1000/W, 4ti-1000/X, 4ti-1001 | CoolCell | FluidX |
| Description | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner A12; working volume: <200μl, total well capacity: 300μl; designed for use on all major cyclers, including ABI® instruments with standard 96 well blocks. Specifically designed to be directly 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner A12; working volume: <200μl, total well capacity: 300μl; designed for use on all major cyclers, including ABI® instruments with standard 96 well blocks. Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at A12
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Perfect for ABI® thermal cyclers & sequencers
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, and black
- Also available as a black frame with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Also available as a clear frame with frosted wells for use with ABI®/LifeTechnologies® qPCR instruments
- Ultra-low DNA binding option available (4ti-LB0770/C) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Ethylene oxide treated option available (4ti-OX770C/SBC) for forensic use
- Available barcoded upon request
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at H1
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request
- Similar plate with a cut corner at A12 for use with ABI® thermal cyclers and sequencers available: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style
... Read More | 4titude 96 well semi-skirted plate, vertically scored, snaps easily into strips of 8 tubes or part plates, cut corner A12; standard profile, 0.2ml polypropylene wells, polycarbonate frame; working volume: <200μl, total well capacity: 300μl. Our FrameStar Breakable Vertically PCR Plates 4titude 96 well semi-skirted plate, vertically scored, snaps easily into strips of 8 tubes or part plates, cut corner A12; standard profile, 0.2ml polypropylene wells, polycarbonate frame; working volume: <200μl, total well capacity: 300μl. Our FrameStar Breakable Vertically PCR Plates utilize the 2-component design of the FrameStar range, which combines the advantages of thin-walled polypropylene tubes for optimum PCR results and a rigid frame portion for easy and reliable handling. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- 2-component design prevents distortion of tube strips
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- Standard 0.2ml (200μl) working volume, with a 0.3ml (300μl) total well capacity when used with sealing options
- End tabs for easy handling and labeling
- Eliminates strip breakage
- Alphanumeric grid reference to aid well and sample identification
- Rigid PCR plate that can be broken into smaller plate sections
- Fits majority of thermal cyclers
- Compatible with standard multichannel pipettes
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, black, and white
- Also available as a black frame with white wells for use with optical assays such as qPCR
- Also available as a FrameStar Breakable Vertically PCR Plate, Low Profile (0.1ml well capacity option)
- 2D coding option
... Read More | Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1?/minute freezing rate when placed in a -80? freezer, with no alcohol or fluids required. The Cell Freezing Container technology utilizes a thermo-conductive alloy core and highly-insulative outer Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1?/minute freezing rate when placed in a -80? freezer, with no alcohol or fluids required. The Cell Freezing Container technology utilizes a thermo-conductive alloy core and highly-insulative outer material to control the rate of heat removal to provide reproducible cell cryopreservation. The insulative outer housing and thermo-conductive solid state core ensure consistent heat removal to all vials throughout the freezing period. Cell Freezing Containers can replace isopropanol-based freezing containers such as Mr. Frosty by ThermoFisher Scientific and others, which can consume up to 12l per year of IPA and cost hundreds of dollars per unit per year to maintain. - Cost saving as no alcohol or fluids required
- Consistent heat removal through freezing period
- Unbreakable, easy and safe to open when frozen
- Easy and fast vial identification and removal
- Quick reuse time: the containers are ready to use again after 5 minutes
- For use with stem cells, primary cells and cell lines
... Read More | FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including cryogenic storage. The external thread design offers a superior seal with higher working volume, while the internal thread caps outperform traditional O-ring seals, preventing leaks during freezing. Developed for manual, semi-automated, or fully automated workflows, FluidX tubes provide reliable sample audit traceability across labs and storage locations.... Read More |