| Catalog Number | 4ti-0770, 4ti-0770/B, 4ti-0770/C, 4ti-0770/C/10P, 4ti-0770/G, 4ti-0770/R, 4ti-0770/X, 4ti-0771, 4ti-0772, 4ti-0772/10P, 4ti-OX770C/SBC, 4ti-LB0770/C | 4ti-0530, 4ti-0530/122, 4ti-0530/REMP, 4ti-0530/S, 4ti-0532, 4ti-0532/REMP, 4ti-0532/S, 4ti-0531, 4ti-0531/GR | 68-0701-00 / 68-0701-01 / 68-0701-02 / 68-0701-10 / 68-0701-11 / 68-0701-12 | FluidX | Thermoconductive Tube Racks |
| Description | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner A12; working volume: <200μl, total well capacity: 300μl; designed for use on all major cyclers, including ABI® instruments with standard 96 well blocks. Specifically designed to be directly 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner A12; working volume: <200μl, total well capacity: 300μl; designed for use on all major cyclers, including ABI® instruments with standard 96 well blocks. Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at A12
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Perfect for ABI® thermal cyclers & sequencers
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, and black
- Also available as a black frame with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Also available as a clear frame with frosted wells for use with ABI®/LifeTechnologies® qPCR instruments
- Ultra-low DNA binding option available (4ti-LB0770/C) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Ethylene oxide treated option available (4ti-OX770C/SBC) for forensic use
- Available barcoded upon request
... Read More | 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and polystyrene plates. This seal demonstrates good solvent resistance and can be used for low temperature and room temperature compound storage in DMSO and organic solvents. Pierce Heat Seal can be pierced with a pipette tip manually, or by a liquid handling robot. This seal can be resealed by applying another Pierce Seal straight on top of a previously pierced seal. A blue stripe on the sheet foils clearly indicates the non-sealing surface, for ease of seal orientation and handling. Pierce Heat Seal sheets are also available with a printed grid reference on the non-sealing surface. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Key Features: - Pierceable
- Resealable
- Seal integrity range: -20°C to 120°C
- Good solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Seals polypropylene and polystyrene plates
- Suitable for long term storage
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Available with printed grid reference (in sheet format, 4ti-0531/GR)
- Non-sterile as standard; sterilization available upon request
- Custom printing available on request
... Read More | FluidX 0.5ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.5ml dual-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent laser etched 2D code and human readable number on tube base, allowing compatibility with low throughput manual, semi-automated or fully automated workflows on integrated platforms. Both codes are identical and auditing processes guarantee both codes match; standard 2D coding option is white on black. ... Read More | FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including cryogenic storage. The external thread design offers a superior seal with higher working volume, while the internal thread caps outperform traditional O-ring seals, preventing leaks during freezing. Developed for manual, semi-automated, or fully automated workflows, FluidX tubes provide reliable sample audit traceability across labs and storage locations.... Read More | Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which originate from tubes placed directly into ice, dry ice, alcohol baths, water baths and other temperature sources. - Ideal for cooling, snap freezing, heating or thawing
- Helps keep samples organized and dry
- All tubes upright and indexed
- Reproducible method
- Removes all problems created by placing sample directly in ice: variable sample temperature, wet labels, contamination risk
On ice - Adapts from ambient (25°C) to <4°c in="" 60-90="">4°c>
- Samples and labels stay dry
- Hours of ice cooling without direct ice contact
On dry ice - Adapts from ambient (25°C) to -78°C in approximately 5-7 minutes*
- Eliminates ethanol from snap freezing
- Equal or better freezing rate as compared to direct immersion into dry ice or alcohol slurry
In liquid nitrogen - Adapts from ambient (25°C) to approximately -150°C in approximately 12-14 minutes*
- Vapor barrier protects from ambient air
- No direct contact between samples and LN2
Heat sources - Use with water baths, hot plates, incubators and other heat sources to keep samples warm
*Average cooling rate from room temperature How it Works: Ease of Use: - Thermoconductive Tube Rack on ice: heat from the relatively warmer Thermoconductive Tube Rack module is transferred to cooling source (wet or dry ice, cartridge, LN2) until equilibrium is reached
- Thermoconductive Tube Rack in water bath: heat is transferred from water bath toward relatively cooler Thermoconductive Tube Rack until equilibrium is reached
... Read More |