| Catalog Number | 4ti-0560, 4ti-0561, 4ti-0561/S | 4ti-0910/C, 4ti-0910/C/10P, 4ti-0911, 4ti-0912, 4ti-0912/10P | 4ti-1200/P, 4ti-1200/B, 4ti-1200/C, 4ti-1200/G, 4ti-1200/R, 4ti-1200/W, 4ti-1200/X, 4ti-1201 | CoolCell | Thermoconductive Tube Racks |
| Description | 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids 4titude optically clear adhesive film, pressure activated adhesive, peelable; suitable for qPCR and other imaging techniques including crystallization Optically clear seal specifically developed for optical applications, particularly qPCR. It is non sticky when removed from the packaging; this aids handling when wearing gloves. The adhesive is contained within small capsules, allowing light to pass through to ensure the optical clarity of the seal. When the seal is in position, pressure can be applied to burst the capsules, releasing a strong adhesive only where the seal touches the raised well rims of the plate - the rest of the seal area above the wells remains optically clear. Key Features: - Non-pierceable
- Peelable
- Seal integrity range: -80°C to 110°C
- Free from DNase, RNase, and human genomic DNA
- Non-sterile
- Applications: qPCR and other fluorescent applications, plate readers, microscopy and protein crystallization (96 or 384 well)
- Removal: will not leave a sticky residue on the plate surface following removal
- Replacement for: ABI® MicroAmp Optical Adhesive film, Absolute qPCR plate seals and Roche LightCycler® sealing foils
- Sheet format: 140 x 77mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates with 96 round wells
- Roll format: 100m x 80mm, approx. 700 seals
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame with upstand, cut corner A1, working volume: <100μl, total well capacity: 200μl; designed for use on ABI® Fast Block cyclers. This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with ABI® Fast block thermal cyclers
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Standard plate comes with clear polypropylene wells with a clear polypropylene frame
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Also available as a clear frame with frosted wells for use with ABI®/LifeTechnologies® qPCR instruments
- Combi packs available (for 4ti-0910/C) with Optically Clear Windowed qPCR Seal (4ti-0565)
- Available barcoded upon request
... Read More | 4titude 96 well semi-skirted plate, vertically scored, snaps easily into strips of 8 tubes or part plates, cut corner A12; low profile, 0.1ml polypropylene wells, polycarbonate frame; working volume: <100μl, total well capacity: 200μl. Our FrameStar Breakable Vertically PCR Plates, Low 4titude 96 well semi-skirted plate, vertically scored, snaps easily into strips of 8 tubes or part plates, cut corner A12; low profile, 0.1ml polypropylene wells, polycarbonate frame; working volume: <100μl, total well capacity: 200μl. Our FrameStar Breakable Vertically PCR Plates, Low Profile utilize the 2-component design of the FrameStar range, which combines the advantages of thin-walled polypropylene tubes for optimum PCR results and a rigid frame portion for easy and reliable handling. This low profile plate has shorter wells than the standard profile plate (4ti-1000), decreasing the "dead space" between the heated lid of the thermal cycler and the sample. This eliminates condensation on the side wall of the tube, preventing reduction in PCR volume and increasing the efficiency of the reaction. Low profile products are especially recommended for use with reaction volumes below 20μl. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- 2-component design prevents distortion of tube strips
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- Low profile 0.1ml (100μl) working volume, with a 0.2ml (200μl) total well capacity when used with sealing options
- End tabs for easy handling and labeling
- Eliminates strip breakage
- Alphanumeric grid reference to aid well and sample identification
- Rigid PCR plate that can be broken into smaller plate sections
- Fits majority of thermal cyclers
- Compatible with standard multichannel pipette
- Available with the following frame color options for the clear well variety: purple, blue, clear, green, red, black, and white
- Also available as a black frame with white wells for use with optical assays such as qPCR
- Also available as FrameStar Breakable Vertically PCR Plate (0.2ml well capacity option)
- 2D coding option
... Read More | Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1?/minute freezing rate when placed in a -80? freezer, with no alcohol or fluids required. The Cell Freezing Container technology utilizes a thermo-conductive alloy core and highly-insulative outer Cell Freezing Containers for controlled-rate alcohol-free cell freezing provide a highly reproducible -1?/minute freezing rate when placed in a -80? freezer, with no alcohol or fluids required. The Cell Freezing Container technology utilizes a thermo-conductive alloy core and highly-insulative outer material to control the rate of heat removal to provide reproducible cell cryopreservation. The insulative outer housing and thermo-conductive solid state core ensure consistent heat removal to all vials throughout the freezing period. Cell Freezing Containers can replace isopropanol-based freezing containers such as Mr. Frosty by ThermoFisher Scientific and others, which can consume up to 12l per year of IPA and cost hundreds of dollars per unit per year to maintain. - Cost saving as no alcohol or fluids required
- Consistent heat removal through freezing period
- Unbreakable, easy and safe to open when frozen
- Easy and fast vial identification and removal
- Quick reuse time: the containers are ready to use again after 5 minutes
- For use with stem cells, primary cells and cell lines
... Read More | Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which Thermoconductive Tube Racks are precision-engineered sample modules manufactured from a novel thermo-conductive alloy material, designed to evenly distribute temperature across all wells providing uniform and consistent temperature to all samples (+/-0.1°C)The modules eliminate variability which originate from tubes placed directly into ice, dry ice, alcohol baths, water baths and other temperature sources. - Ideal for cooling, snap freezing, heating or thawing
- Helps keep samples organized and dry
- All tubes upright and indexed
- Reproducible method
- Removes all problems created by placing sample directly in ice: variable sample temperature, wet labels, contamination risk
On ice - Adapts from ambient (25°C) to <4°c in="" 60-90="">4°c>
- Samples and labels stay dry
- Hours of ice cooling without direct ice contact
On dry ice - Adapts from ambient (25°C) to -78°C in approximately 5-7 minutes*
- Eliminates ethanol from snap freezing
- Equal or better freezing rate as compared to direct immersion into dry ice or alcohol slurry
In liquid nitrogen - Adapts from ambient (25°C) to approximately -150°C in approximately 12-14 minutes*
- Vapor barrier protects from ambient air
- No direct contact between samples and LN2
Heat sources - Use with water baths, hot plates, incubators and other heat sources to keep samples warm
*Average cooling rate from room temperature How it Works: Ease of Use: - Thermoconductive Tube Rack on ice: heat from the relatively warmer Thermoconductive Tube Rack module is transferred to cooling source (wet or dry ice, cartridge, LN2) until equilibrium is reached
- Thermoconductive Tube Rack in water bath: heat is transferred from water bath toward relatively cooler Thermoconductive Tube Rack until equilibrium is reached
... Read More |
| Applications | qPCR, Fluorescent Applications, Plate Readers, Microscopy Protein Crystallization (96 or 384 well) | PCR, qPCR, NGS | PCR, qPCR, NGS | Suitable for use with Stem cells, including human and mouse embryonic, breast and colon cancer, preadipocytes, progenitor, human endothelial, glioblastoma. Primary cells, including WBCs, human cardiac, muscle, mouse. Cell lines, including CHO, LnCap, HTB77, A549, HeLa. | Suggested applications include cooling reagents such as restriction enzymes, dNTPs and antibodies, alcohol-free dry ice snap freezing of tissue, virus and bacteria samples and bench top cryogenic tube sorting in liquid nitrogen |