Lab consumables include a range of supplies used in the laboratory and laboratory testing. Consumables used in the laboratory are those items that must be replaced regularly when they are used or wear down. The types of labware include glassware, plasticware and general lab supplies while the types of consumables include but not limited to tubes, strips, filters, kits, reagents, caps, tips, gloves, and more.
Find, compare, and request a quote for lab consumables across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | Gilson Inc | Gilson Inc | Gilson Inc | Gilson Inc | Gilson Inc |
| Item | Code 371 Rack, ASPEC® 1 mL 36 Positions | 807 Manometric, 10-200 mL/min, 1200 psi | EXTRACTMAN Starter Kit | O-RING, FOR P10ML, 25 UNITS | VERITY® 271 LCMS System |
| Catalog Number | 260440044 | 361737 | 22100000 | F161813 | GSYS0005 |
| Price | Supplier Page | Supplier Page | Supplier Page | Supplier Page | Supplier Page |
| Description | Individual ASPEC SPE rack including metallic stand, mobile holder for cartridges (1, 3 or 6 mL), waste drain container, and rack for collection tubes. | Gilson Manometric Modules are used with the Gilson 305/306 piston-pumping systems. One manometric module is needed in each system to provide pulse-free operation and pressure monitoring. Various Options Available Three models are available; each is designed for a specified range of pressures and Gilson Manometric Modules are used with the Gilson 305/306 piston-pumping systems. One manometric module is needed in each system to provide pulse-free operation and pressure monitoring. Various Options Available Three models are available; each is designed for a specified range of pressures and flow rates. Together, the three models cover the entire range of analytical and preparative liquid chromatography at the laboratory scale.- Model 805 is for analytical applications with operating pressures up to 60 MPa (600 bar or 8.7 kpsi)
- Model 806 is suitable for preparative uses with operating pressures up to 32 MPa (320 bar or 4.6 kpsi)
- Model 807 is specially designed to meet the requirements of low pressure preparative applications up to 8 MPa (80 bar or 1.2 kpsi)
... Read More | Make Your Lab as Smart as Your Science EXTRACTMAN®, an innovative magnetic bead extraction platform, offers a faster and gentler approach to isolating target proteins from a variety of samples. EXTRACTMAN differs from traditional magnetic bead-based co-IP techniques by using Exclusion-based Sample Make Your Lab as Smart as Your Science EXTRACTMAN®, an innovative magnetic bead extraction platform, offers a faster and gentler approach to isolating target proteins from a variety of samples. EXTRACTMAN differs from traditional magnetic bead-based co-IP techniques by using Exclusion-based Sample Preparation (ESP™) technology, making it ideal for capturing weakly bound protein complexes without exposing them to high shear forces from pipette-based wash steps. Paired with non-porous magnetic beads, EXTRACTMAN enables high-yield, high-purity isolations without the need for long washing steps. Removes Purification Bottlenecks ESP™ magnetic bead technology purifies samples faster than other magnetic bead technologies by reducing the pipetting steps. The technology does not move liquids, but instead beads are gently handled to protect sample integrity. Discovers Weak and Transient Interactions Because analytes are magnetically extracted from samples without diluting, destroying, or otherwise disturbing the original sample, EXTRACTMAN is particularly efficient to discover difficult-to-capture interactions. Ergonomic and Easy to Use A simple slide of the handle isolates target proteins, which allows EXTRACTMAN to be used as a universal platform for a variety of commercial magnetic beads kits. EXTRACTMAN – A Novel Platform for Target Protein Isolation Josh Martin, a graduate research assistant and Ph.D. candidate with the McCardle Laboratory for Cancer Research, discusses how EXTRACTMAN helps to overcome limitations of the immunoprecipitation techniques that aim to identify and isolate binding partners of proteins. The EXTRACTMAN® Starter Kit allows you to be extracting in just minutes. The EXTRACTMAN Starter Kit includes: EXTRACTMAN Handle Assembly EXTRACTMAN Base Assembly Bead Collection Strips X 5 EXTRACTMAN 15 µL Extraction Plates X 5 EXTRACTMAN User's Guide ... Read More | O-RING, FOR P10ML, 25 UNITS | The VERITY® 271 LCMS system combines the greater selectivity of mass detection with the versatility of a mid-size capacity platform for semi-preparative to preparative HPLC purifications. All configurations accommodate novel injection and fraction collection capabilities within a single platform, The VERITY® 271 LCMS system combines the greater selectivity of mass detection with the versatility of a mid-size capacity platform for semi-preparative to preparative HPLC purifications. All configurations accommodate novel injection and fraction collection capabilities within a single platform, with the single quad VERITY® 1920 Mass Spectrometer equipped with electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) ion source. This is the ideal solution for peptide purification and laboratories seeking effective MS detection to isolate pure compounds from synthetic and natural products from lab to pilot scale. The VERITY 271 LCMS system makes mass detection affordable and straightforward for any purification work. Mid-Throughput Purification in a Small Footprint The VERITY 271 LCMS Systems are built around the VERITY GX-271 liquid handler/fraction collector with a bench-saving footprint featuring separate fluid pathways for samples and fractions collection. With the GX Direct Injection Module, the system accommodates injection loop volumes of 2 µL to 25 mL and tens of samples and fractions collection vessels from a few milliliters to hundreds of milliliters. Purify with Confidence With the VERITY® 1920 MS, you'll save valuable time and maximize productivity as targeted fraction collection reduces post-purification work and purity analysis. With a mass range of 10-2000 m/z, the VERITY 1920 MS helps you easily detect large molecules such as peptides and small proteins. Many biomolecules carry multiple charges with electrospray ionization, so even proteins of several tens of kDa can be measured within the 2,000 m/z range. Modular Components Provide a Multitude of Options Using this mid-capacity liquid handler as a starting point, choose from several high-pressure gradient mixing pumping solutions, achieving flow rates up to 200 mL/min and pressures up to 8700 psi (600 bar), and combine it with one of the valve switching options available to automate any purification workflows. Gilson systems can support scaling up from 4.6 mm up to 50 mm ID columns. Easy-to-Use Software Control TRILUTION LC Software controls the entire VERITY 271 LCMS system, allowing your focus to remain on the science rather than the software. Using the powerful TRILUTION® LC software, safely automate purification workflow, including method screening, scout runs, purification runs, or fractions reinjection or share usage with the Open Access Capabilities.... Read More |
| Type | Inquire | Inquire | Lab supplies & consumables | Inquire | Inquire |
| Quantity | EA | EA | 1 | EA | EA |
| Get Quote | Supplier Page | Supplier Page | Supplier Page | Supplier Page | Supplier Page |