| Description | The VERITY® GPC Cleanup System is an ideal solution for post-extraction cleanup of high-molecular-weight interfering substances from environmental samples, food products, and animal tissue before analysis using gel permeation chromatography (GPC). Removing these contaminants leads to more reliable The VERITY® GPC Cleanup System is an ideal solution for post-extraction cleanup of high-molecular-weight interfering substances from environmental samples, food products, and animal tissue before analysis using gel permeation chromatography (GPC). Removing these contaminants leads to more reliable results, fewer sample repeats, and less downtime for downstream chromatography instruments. Automated GPC Cleanup for a Variety of Substances The automated VERITY GPC Cleanup System provides a post-extraction purification solution that removes matrix interferences before GC, GC/MS, HPLC, or LC/MS, extending the life of chromatography columns, protecting chromatography instruments, improving analytical accuracy, and lowering detection limits. The system removes substances such as lipids, proteins, cell debris, pigments, humic acid, and more that can interfere with the analysis of pharmaceuticals and residues (pesticide residues, semi-volatiles, PAHs, PCBs, mycotoxins, pharmaceuticals, and antibiotics) from animal tissue, fatty foods, plant tissue, soils sediment, sludge, and wastewater. The VERITY GPC Cleanup System automates the cleanup of up to 80 sample extracts and can collect multiple fractions from the same extract, all with reduced sample carryover. All Under TRILUTION® LC Control The powerful TRILUTION LC software controls the VERITY GPC Cleanup System. The software contains preprogrammed methods for GPC post-extraction cleanup. The software error handling and shutdown methods help to minimize solvent waste and sample loss. Meets Government Requirements for GPC Cleanup USEPA, USDA, USFDA, USGS, USDI, Centers for Disease Control (CDC), Canadian Food Inspection Agency (CFIA), European Union (EN 1528, 12393, DFG S19), AOAC International, JIS, GB/T 14552, etc. Optional UV-VIS Detector To comply with US EPA regulations, outfit your VERITY GPC System with VERITY® 1741 UV-VIS Detector and preparative flow cell.... Read More | CytoPur™ Reagent Reservoirs are sterile, single-use accessories, designed to give you peace of mind in your most sensitive workflows. Certified DNase-, RNase-, and pyrogen-free, with a Sterility Assurance Level (SAL) of 10?6, they provide the highest level of purity so you can focus on your results CytoPur™ Reagent Reservoirs are sterile, single-use accessories, designed to give you peace of mind in your most sensitive workflows. Certified DNase-, RNase-, and pyrogen-free, with a Sterility Assurance Level (SAL) of 10?6, they provide the highest level of purity so you can focus on your results even in sensitive workflows, not contamination risks. Each reservoir is individually wrapped to maintain sterility until you need it. They are available in 10 mL, 25 mL, and 50 mL formats, they give you the flexibility required for molecular biology, cell culture, and biomedical research applications. Engineered for precision, the V-shaped bottom maximizes liquid recovery and improves pipetting accuracy. Graduation markings on the inner walls allow easy and accurate measurement of liquids, helping to minimize waste of costly reagents. CytoPur Reagent Reservoirs are fully compatible with both single and multichannel pipettes, making them suitable for a wide range of manual workflows.... Read More | These empty racks can be used for ECOPACK™ and EASYPACK™ loose tips. | TRILUTION® micro Software manages your automated PIPETMAX® workflows, allowing you to focus on more important tasks. The software is easy to learn and allows anyone in the lab to effortlessly manage PIPETMAX tasks. Easy to learn TRILUTION micro Software, the runtime control software for TRILUTION® micro Software manages your automated PIPETMAX® workflows, allowing you to focus on more important tasks. The software is easy to learn and allows anyone in the lab to effortlessly manage PIPETMAX tasks. Easy to learn TRILUTION micro Software, the runtime control software for PIPETMAX, takes only minutes to learn, unlike other automated sample preparation solutions that require extensive training, or even dedicated technicians. From a single screen, TRILUTION micro lets you: • Manage protocol managements, including importing, exporting, and deleting protocols • Simulate and run protocols • Manually control processes With the latest version 3.0, TRILUTION micro Software streamlines steps to rack editing and running protocols. TRILUTION micro Software v3.0 is available for Windows® 10 operating systems. Improved reproducibility and traceability for PCR and qPCR experiments The qPCR Assistant add-on allows you to create PCR/qPCR methods that support sample dilution, master mix preparation and plate preparation. By automating these steps using PIPETMAX, you increase accuracy and reliability by minimizing variability and contamination sources. With the qPCR Assistant, it’s easy to import sample information and export templates to different thermocyclers, adding a new level traceability of your experiments. No more tedious normalization calculations With the Normalization Assistant add-on, anyone in the lab can create fully automated DNA or RNA normalization protocols on PIPETMAX. Normalization Assistant automates the tedious calculations and sample tracking tasks required for normalization runs, improving traceability and reliability to your sample preparations. ... Read More | These HPLC valves are for the VALVEMATE® II Valve Actuator and are often used for column switching or solvent selection in HPLC applications. They are available in a variety of configurations for both high and low pressures and for analytical or preparative applications. They are available in These HPLC valves are for the VALVEMATE® II Valve Actuator and are often used for column switching or solvent selection in HPLC applications. They are available in a variety of configurations for both high and low pressures and for analytical or preparative applications. They are available in stainless steel or bio-compatible materials.... Read More |