| Description | The VERITY® GPC Cleanup System is an ideal solution for post-extraction cleanup of high-molecular-weight interfering substances from environmental samples, food products, and animal tissue before analysis using gel permeation chromatography (GPC). Removing these contaminants leads to more reliable The VERITY® GPC Cleanup System is an ideal solution for post-extraction cleanup of high-molecular-weight interfering substances from environmental samples, food products, and animal tissue before analysis using gel permeation chromatography (GPC). Removing these contaminants leads to more reliable results, fewer sample repeats, and less downtime for downstream chromatography instruments. Automated GPC Cleanup for a Variety of Substances The automated VERITY GPC Cleanup System provides a post-extraction purification solution that removes matrix interferences before GC, GC/MS, HPLC, or LC/MS, extending the life of chromatography columns, protecting chromatography instruments, improving analytical accuracy, and lowering detection limits. The system removes substances such as lipids, proteins, cell debris, pigments, humic acid, and more that can interfere with the analysis of pharmaceuticals and residues (pesticide residues, semi-volatiles, PAHs, PCBs, mycotoxins, pharmaceuticals, and antibiotics) from animal tissue, fatty foods, plant tissue, soils sediment, sludge, and wastewater. The VERITY GPC Cleanup System automates the cleanup of up to 80 sample extracts and can collect multiple fractions from the same extract, all with reduced sample carryover. All Under TRILUTION® LC Control The powerful TRILUTION LC software controls the VERITY GPC Cleanup System. The software contains preprogrammed methods for GPC post-extraction cleanup. The software error handling and shutdown methods help to minimize solvent waste and sample loss. VERITY® 1741 UV-VIS Detector The detector can calibrate the GPC column per regulation standards. This VERITY GPC System includes a VERITY 1741 UV-VIS Detector and preparative flow cell to comply with regulations. It meets government requirements for GPC cleanup, including USEPA, USDA, USFDA, USGS, USDI, Centers for Disease Control (CDC), Canadian Food Inspection Agency (CFIA), European Union (EN 1528, 12393, DFG S19), AOAC International, JIS, GB/T 14552, etc.... Read More | DISTRITIPS® are polypropylene syringes with easy-to-read level indicators that are used with DISTRIMAN®, a positive-displacement, continuously adjustable, mechanical repeater pipette. Accurate and Precise - Using DISTRITIPS with DISTRIMAN delivers reliable performance and provides more accurate and DISTRITIPS® are polypropylene syringes with easy-to-read level indicators that are used with DISTRIMAN®, a positive-displacement, continuously adjustable, mechanical repeater pipette. Accurate and Precise - Using DISTRITIPS with DISTRIMAN delivers reliable performance and provides more accurate and precise measurements for difficult-to-pipette samples such as viscous, dense, volatile, hazardous, or hot or cold liquids. Free of Detectable Contaminants - DISTRITIPS are made of pure polypropylene and are free of dyes so there is no risk of chemical contamination from the tips. Individually wrapped, sterilized DISTRITIPS are gamma-irradiated and are certified free of detectable DNA, RNA, DNases, RNases, and proteases. Economical - Only three DISTRITIPS cover a large range of aliquot volumes from 1 µL to 1.25 mL. More than 100 aliquots can be dispensed with each syringe, eliminating time-consuming refills. ... Read More | These empty racks can be used for ECOPACK™ and EASYPACK™ loose tips. | Inquire | Designed for semi-preparative to preparative HPLC modular systems, the VERITY® 1741 UV-VIS Detector has the ability to scan multiple different wavelengths simultaneously. It provides more significant detection information required for a wide array of purification applications. Designed for Semi-Designed for semi-preparative to preparative HPLC modular systems, the VERITY® 1741 UV-VIS Detector has the ability to scan multiple different wavelengths simultaneously. It provides more significant detection information required for a wide array of purification applications. Designed for Semi-Preparative and Preparative HPLC The reliable and versatile VERITY 1741 Detector has a large scanning range of 200–800 nm and offers flow cell pathlengths ranging from 0.05 to 5 mm with a compatible flow rate of up to 700 mL/min. Easy-to-use at a Low Cost of Ownership Features a large display for stand-alone operation and offers a built-in counter for monitoring lamp life, helping you avoid purification interruptions. The easy-to-replace flow cells and long-life lamp decrease the detector’s downtime, saving you money. Fully Integrated with TRILUTION® LC Software TRILUTION® LC Software for purification fully controls the detector to monitor up to eight different wavelengths to trigger fraction collection and display real-time spectra. The VERITY 1741 Detector is a powerful addition to our VERITY® preparative HPLC systems that allows safe compound purification. Verifiable Scientific Results Require Reliable Purification Systems Get the accuracy and precision you need for trusted results with VERITY® purification systems. Whether you isolate large or small molecules or need milligram to kilogram purifications, our VERITY systems offer you a wide array of components to build the perfect system to meet your specific needs. All systems are easily controlled by intuitive software, letting you focus on science. Backed by our long history in chromatography, you are reassured that VERITY solutions are built to last and will make your life in the lab easier.... Read More |