| Catalog Number | 4ti-0590, 4ti-0590/100, 4ti-0590/S, 4ti-0592, 4ti-0592/S, 4ti-0591 | 4ti-0573, 4ti-0573/122, 4ti-0573/S, 4ti-0574, 4ti-0574/S, 4ti-0575 | 4ti-0535, 4ti-0535/122, 4ti-0535/REMP, 4ti-0535/S, 4ti-0537, 4ti-0537/REMP, 4ti-0537/S, 4ti-0536 | 4ti-0530, 4ti-0530/122, 4ti-0530/REMP, 4ti-0530/S, 4ti-0532, 4ti-0532/REMP, 4ti-0532/S, 4ti-0531, 4ti-0531/GR | TruCool™ Hinged CryoBoxes |
| Description | 4titude heavy duty heat sealing foil, peelable; suitable for long term storage, transportation Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Our Thermal Bond Heat Seal is a heavy duty laminate foil seal suitable 4titude heavy duty heat sealing foil, peelable; suitable for long term storage, transportation Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Our Thermal Bond Heat Seal is a heavy duty laminate foil seal suitable for providing a very strong, but peelable seal. The seal is compatible with polypropylene plates to provide a high degree of sample protection. It demonstrates very good solvent resistance and can be used for very low temperature compound storage, in DMSO and organic solvents, and long term room temperature storage such that it is recommended as suitable for sample transportation. The seal can be pierced only by using a blade or using the Pierce Plate (4ti-0398). This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Key Features: - Peelable
- Seal integrity range: -200°C to 110°C
- High solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Recommended for PCR, including with water bath thermal cyclers
- Seals polypropylene plates
- Suitable for long term storage and transportation
- Suitable for very low temperature storage
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Non-sterile as standard; sterilization available upon request
... Read More | 4titude optically clear heat sealing film, non-peelable, difficult to pierce; suitable for qPCR, optical applications and storage Heat sealing offers a 100% effective method for plate sealing for a complete seal integrity, as well as being quick and cost effective. Our Clear Weld Heat Seal is an 4titude optically clear heat sealing film, non-peelable, difficult to pierce; suitable for qPCR, optical applications and storage Heat sealing offers a 100% effective method for plate sealing for a complete seal integrity, as well as being quick and cost effective. Our Clear Weld Heat Seal is an optically clear polymer film forming a permanent seal to polypropylene plates. The optical clarity of this seal enables its use for sealing plates required for imaging use, including fluorescent detection methods such as qPCR and colorimetric assays. The Clear Weld Heat Seal forms a complete seal to a plate, enabling both low and very high temperature uses, including low temperature storage and high temperature incubations. This seal is suitable for PCR/qPCR, even without the use of a pressurized heated lid, and is 100% effective when used in water bath thermal cyclers. The permanent nature of this 100% effective seal renders it suitable for the storage and disposal of hazardous material. Clear Weld Heat Seal demonstrates a good solvent resistance and can be utilized for long term compound storage. Samples can be accessed by pre-piercing with a blade, needle or our Pierce Plate (4ti-0398). This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Key Features: - Permanent seal
- Difficult to pierce
- Non-peelable
- Seal integrity range: -80°C to 110°C
- DMSO and solvent resistant
- Autoclavable (121°C)*
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Applications: suitable for PCR and qPCR, long term storage, and disposal of hazardous materials
- Seals polypropylene plates
- Compatible with water bath thermal cyclers
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Non-sterile as standard; sterilization available upon request
* Once autoclaved, not recommended for PCR applications. ... Read More | 4titude aluminum heat sealing foil, resealable, peelable, pierceable; suitable for compound storage, PCR Our Foil Heat Seal is compatible with polypropylene and polystyrene plates. This seal demonstrates moderate solvent resistance and can be used for low temperature compound storage in DMSO and 4titude aluminum heat sealing foil, resealable, peelable, pierceable; suitable for compound storage, PCR Our Foil Heat Seal is compatible with polypropylene and polystyrene plates. This seal demonstrates moderate solvent resistance and can be used for low temperature compound storage in DMSO and organic solvents and short term room temperature storage. The Foil Heat Seal can be pierced with a pipette tip, manually or by liquid handling robots, or it can be removed by peeling. It can be resealed by applying another Foil Heat Seal directly on top of a previously pierced seal. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. A red stripe on the sheet foils clearly indicates the non-sealing surface, for ease of seal orientation and handling. Key Features: - Pierceable
- Peelable
- Resealable
- Seal integrity range: -20°C to 110°C
- Moderate solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Seals polypropylene and polystyrene plates
- Suitable for short term storage
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Non-sterile as standard; sterilization available upon request
... Read More | 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and 4titude pierceable heat sealing foil, high solvent resistance, resealable, suitable for PCR/storage/shipping Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective. Pierce Heat Seal is compatible with polypropylene and polystyrene plates. This seal demonstrates good solvent resistance and can be used for low temperature and room temperature compound storage in DMSO and organic solvents. Pierce Heat Seal can be pierced with a pipette tip manually, or by a liquid handling robot. This seal can be resealed by applying another Pierce Seal straight on top of a previously pierced seal. A blue stripe on the sheet foils clearly indicates the non-sealing surface, for ease of seal orientation and handling. Pierce Heat Seal sheets are also available with a printed grid reference on the non-sealing surface. This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer. Also available in multiple roll formats compatible with specified automated heat sealers, such as our Automated Roll Heat Sealer. Key Features: - Pierceable
- Resealable
- Seal integrity range: -20°C to 120°C
- Good solvent resistance
- Autoclavable (121°C)
- Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Seals polypropylene and polystyrene plates
- Suitable for long term storage
- Sheet format: 125 x 78mm, to fit all standard SBS footprint PCR and qPCR plates, microplates, assay and storage plates, from 12 well to 1536 well
- Roll format: available in a variety of roll dimensions, to suit your choice of automatic heat sealing equipment
- Available with printed grid reference (in sheet format, 4ti-0531/GR)
- Non-sterile as standard; sterilization available upon request
- Custom printing available on request
... Read More | Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Azenta Life Sciences Hinged CryoBoxes feature a patented hinged lid that offers convenience and archival integrity, ensuring IDs and vials remain coordinated. To minimize the risk of separation and contamination the lid is fastened to the base, making it easy to open and close even when frozen. Feature plastic, adjustable slats that can be moved to accommodate multiple vial sizes. Recommended for use at room temperature, 4°C, -20°C and -80°C. - Lid fastened to the base
- Easy to close/open even when frozen and minimized contamination risk due to patented hinged lid
- Plastic dividers for protection during exposure
- Laminated fiberboard for durability and water resistance
- Grid numbers listed on top, inside and bottom for better tracking
- Different color options for easier tracking
- Recommended for use from room temperature to -80°C
- Hinged CryoBox with Drain Holes suitable at vapor phase LN2
- Adjustable slats can be moved to accommodate multiple vial sizes
... Read More |