| Catalog Number | 67-63111-10 / 67-63111-50 / 68-53111-10N / 68-53111-50N / 68-53111-50X | 4ti-0201, 4ti-0203, 4ti-0204, 4ti-0280, 4ti-0281 | 4ti-0900/C, 4ti-0901 | 4ti-0960, 4ti-0960/B, 4ti-0960/C, 4ti-0960/G, 4ti-0960/R, 4ti-0960/X, 4ti-0960/W, 4ti-0961, 4ti-0961/C, 4ti-0966, 4ti-OX960C/SBC, 4ti-0960/RIG, 4ti-LB0960/RIG | FluidX |
| Description | FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available
FluidX cap carriers enable automated capping of 96-format sample storage tubes, leading to improved process efficiency and allowing batch filling of tubes prior to capping - Suitable automated and manual capping
- Available in 96-format SBS footprint
- For use with external/internal thread tubes
- Available empty or pre-filled with caps
Suitable for manual use or for use with Azenta Life Sciences Semi-Automated Screw Cap Decappers/Recappers, Single Channel and IntelliXcap™ Automated Screw Cap Decappers/Recappers. - Enable uncapped tubes to be used immediately and then capped using an automated capping and de-capping system
- When used manually, by transferring caps from the carrier to the tube using a single tube transfer device, the operation becomes faster and the risk of contamination is reduced as cap handling is eliminated
- Available in cases of 10 or 50, empty or pre-filled with low-retention screw caps that can reduce sample loss
... Read More | 4titude 190μm clear base imaging microplate, black frame. Optically Clear Tissue Culture Plates have been designed for high content screening (HCS) assays in drug development and related areas. They are also suitable for homogeneous assays, employing fluorescence intensity, FRET and TR-FRET 4titude 190μm clear base imaging microplate, black frame. Optically Clear Tissue Culture Plates have been designed for high content screening (HCS) assays in drug development and related areas. They are also suitable for homogeneous assays, employing fluorescence intensity, FRET and TR-FRET where measurements are bottom-read. The high-quality optical base plate assures the necessary accuracy and consistency for automated high throughput systems, generating optimum signal-to-noise ratios. Using state-of-the-art manufacturing technology, we have developed a product which offers several key advantages to the end user. Optically Clear Tissue Culture Plates are assembled using unique patented laser welding technology which reduces auto fluorescence and does not inhibit cell growth. Available with 190μm polystyrene base. Available TC treated: our advanced tissue-culture (TC) treatment method evenly coats each well for optimal cell adhesion properties for highest reproducibility between wells, plates and batches. Key Features: - Leak free
- Free from DNase, RNase, human genomic DNA, and cyto-toxic
- Optimum signal-to-noise ratios
- Good cell adhesion
- Wicking and bubble formation eliminated
- SBS footprint
- Alphanumeric grid reference
- Recommended for confocal microscopy due to reduced cross-talk and superior base flatness
- Reduced auto fluorescence ensures their suitability for fluorescent assays
- Suitable for assays that measure absorbance in the visible light range (400-900nm wavelengths)
- Suitable for colorimetric assays
- Suitable for homogeneous assays
- Suitable for use in BMG lab tech, Molecular Devices, Promega Glomax and other plate readers
- Suitable for adhesive and heat sealing: our Moisture Barrier Seal 384 (4ti-0516/96) is recommended as it is optically clear and allows repeated imaging without removal, reducing contamination risks
- Available with 190μm polystyrene base
- All plates come sterilized, apart from 4ti-0204
- TC treated option available (4ti-0201)
- Available barcoded upon request
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal semi-skirted plate designed for use on standard thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Cut corner at H1
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request
- Similar plate with a cut corner at A12 for use with ABI® thermal cyclers and sequencers available: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H1; working volume: <100μl, total well capacity: 200μl. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Ethylene oxide treated option available (4ti-OX960C/SBC) for forensic use
- Ultra-low DNA binding option available (4ti-LB0960/RIG) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
- Clear Polystyrene Lid (4ti-0287) available for 4ti-0960/RIG
... Read More | FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including FluidX™ dual-coded, 2D-coded, and tri-coded sample tubes from Azenta offer optimal compatibility with automated systems for tracking, capping, and sample management. These tubes provide a lifelong, secure chain of custody for samples in biobanks, compound libraries, and chemical stores, including cryogenic storage. The external thread design offers a superior seal with higher working volume, while the internal thread caps outperform traditional O-ring seals, preventing leaks during freezing. Developed for manual, semi-automated, or fully automated workflows, FluidX tubes provide reliable sample audit traceability across labs and storage locations.... Read More |