| Catalog Number | 4ti-0960/RA, 4ti-0960/RA-F | 4ti-0950W-F, 4ti-0753/950W, 4ti-0753, 4ti-0753/C | 4ti-0384, 4ti-0384/B, 4ti-0384/C, 4ti-0384/G, 4ti-0384/R, 4ti-0384/X, 4ti-0385, 4ti-0386, 4ti-0387, 4ti-LB0384/C | 65-7650 / 65-7651 / 65-7652 / 65-7653 | 65-73000 / 65-73000-10 / 65-73001 / 65-73001-10 / 65-73002 / 65-73002-10 / 65-73003 / 65-73003-10 / 65-73004 / 65-73004-10 / 65-74000 |
| Description | 4titude low profile, individually removable 0.1ml polypropylene wells, rigid polycarbonate frame, cut corner H1, working volume: <100μl, total well capacity: 200μl. 96 Well, fully skirted, low profile format with each tube inserted separately into the plate frame, allowing for selection 4titude low profile, individually removable 0.1ml polypropylene wells, rigid polycarbonate frame, cut corner H1, working volume: <100μl, total well capacity: 200μl. 96 Well, fully skirted, low profile format with each tube inserted separately into the plate frame, allowing for selection and removal of individual tubes from the plate. Each tube clicks into place in the frame ensuring tubes are secure once inserted. The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR. Together with the SBS footprint, this makes the plate suitable for use with robotic systems, ideal for both small to high throughput labs. Empty frames are available for tubes to be transferred to. The frames can be re-used multiple times, depending on the application. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Individually removable from the rigid frame, while the rest of the tubes can remain in storage, reducing freeze-thawing of the whole plate
- Thin walled tubes are made from PP for optimal results in (q)PCR whilst also being suitable for storage and incubation
- <100μl working volume, <200μl total well capacity
- Rigid polycarbonate frame provides mechanical stability of the plate
- Alphanumeric grid reference to aid well and sample identification
- Ideal for use with robotic systems
- Fewer transfer steps as the same tube can be used for both (q)PCR and storage
- Each tube can still be separated after sealing
- Each tube can be individually heat sealed using the Individual Access Pierce Heat Seal Strong, such as the contents of each tube is left secure from cross contamination and evaporation for storage and transfer
- Empty frames are available for tubes to be transferred to; frames can be re-used multiple times, depending on the application
- The plate can be sealed in one step using Individual Access Pierce Heat Seal Strong (4ti-05381/RA) on the Semi-Automated Sheet Heat Sealer (using the 59-2005 Individual Access adapter), resulting in individually sealed tubes with pierceable seals to allow for sample access
- Available barcoded upon request
- We also offer customization of the Individual Access Plates such as color coding of the individual wells; please contact an expert for details
... Read More | 4titude rigid polycarbonate frame, for use with Removable 8 Well PCR Tube Strips; for use on Roche LightCycler® 480. These frames of 96 Well Semi-Skirted PCR Plate for Removable 8 Well Tube Strips, Roche Style are molded from rigid polycarbonate for use with our polypropylene Removable 8 Well 4titude rigid polycarbonate frame, for use with Removable 8 Well PCR Tube Strips; for use on Roche LightCycler® 480. These frames of 96 Well Semi-Skirted PCR Plate for Removable 8 Well Tube Strips, Roche Style are molded from rigid polycarbonate for use with our polypropylene Removable 8 Well PCR Tube Strips. The Removable 8 Well PCR Tube Strips are inserted into the frames to form a complete plate, part plate, or individual strip with an easy-to-handle frame. As the Removable 8 Well PCR Tube Strips are interchangeable with the frames, the frames themselves are re-usable; simply purchase more Removable 8 Well PCR Tube Strips to use. The frames can be purchased separately, or pre-loaded with Removable 8 Well PCR Tube Strips. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- The Removable 8 Well PCR Tube Strips have ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- The Removable 8 Well PCR Tube Strips have a low profile 0.1ml (100μl) working volume, with a 0.2ml (200μl) total well capacity when used with sealing options
- Raised well rims prevent cross contamination and facilitate effective sealing for reduced evaporation
- Rigid polycarbonate frames, which reduce thermal expansion and sample evaporation during PCR, leading to improved consistency in PCR results
- Alphanumeric grid reference to aid well and sample identification
- Compatible with standard multichannel pipettes
- Available as a 96 Well Semi-Skirted Frame, Roche Style for use with the Roche LightCycler® 480
- Also available as a 96 Well Skirted Frame for universal use
- Frames can be purchased on their own or pre-loaded with Removable 8 Well PCR Tube Strips
- The Removable 8 Well PCR Tube Strips are available with clear wells
- The Removable 8 Well PCR Tube Strips also available with white wells, giving the highest sensitivity and consistency for fluorescent detection during qPCR
- Available barcoded upon request
... Read More | 4titude polypropylene wells, polycarbonate frame, cut corner A24; working volume: <30μl, total well capacity: 55μl; designed for use on standard thermal cyclers. Our FrameStar 384 Well Skirted PCR Plates are designed for high-throughput PCR. They are compatible with the majority of 384 4titude polypropylene wells, polycarbonate frame, cut corner A24; working volume: <30μl, total well capacity: 55μl; designed for use on standard thermal cyclers. Our FrameStar 384 Well Skirted PCR Plates are designed for high-throughput PCR. They are compatible with the majority of 384 well block PCR, qPCR and sequencing instruments. The rigid 2-component design eliminates warping and distortion during PCR making it ideal for use with robotic systems. The skirt allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Stackable
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <30μl working volume, 55μl total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of the frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Ideal for use with robotic systems
- Ultra-low DNA binding option available (4ti-LB0147) for sensitive applications with ultra-low DNA input and for maximum DNA recovery after low temperature storage and high temperature incubation
- Available barcoded upon request
... Read More | Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample retrieval, therefore creating a reduction in reagent wastage resulting in cost savings. Azenta Life Sciences tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. - Unique design with combined ?v? and ?u? shaped bottom
- Sample identification from 1D, 2D and human readable code
- Capability to work with automation, designed for liquid handlers
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 48-well format SBS racks or bulk
Suitable for use with liquid handling automation, whether reformatting, cherry picking, aliquoting an/or normalization. The 1.6ml Maximum Recovery tube offers unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. ... Read More | FluidX TPE septum caps have been developed to meet the demands of sample security, management and tracking in modern high-density storage applications. A cost effective sealing option for samples that are only accessed occasionally. Compatible with 96-format tubes, available for use with internal FluidX TPE septum caps have been developed to meet the demands of sample security, management and tracking in modern high-density storage applications. A cost effective sealing option for samples that are only accessed occasionally. Compatible with 96-format tubes, available for use with internal thread tubes and suitable for use with automatic and semi-automatic cappers and de-cappers. - Optimal seal quality
- Suitable for cryogenic storage as low as -80°C
- Manufactured from high-quality thermo plastic elastomer (TPE)
- Available on backing mats to help facilitate automation or bulk
- Pierceable and disposable
- Suitable for sealing internal thread tubes, compatible with Azenta internal 96-format tubes
- Internal thread caps come in a choice of five colors to aid sample identification
- Broad operating temperature range: -80°C to +110°C
- Ideal solution for -20°C storage with occasional access
... Read More |
| Applications | PCR, qPCR, NGS | PCR, qPCR, NGS | PCR, qPCR, NGS | (For research use only) Liquid Handling workflows, Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |