| Description | 4titude 190μm clear base imaging microplate, black frame. Optically Clear Tissue Culture Plates have been designed for high content screening (HCS) assays in drug development and related areas. They are also suitable for homogeneous assays, employing fluorescence intensity, FRET and TR-FRET 4titude 190μm clear base imaging microplate, black frame. Optically Clear Tissue Culture Plates have been designed for high content screening (HCS) assays in drug development and related areas. They are also suitable for homogeneous assays, employing fluorescence intensity, FRET and TR-FRET where measurements are bottom-read. The high-quality optical base plate assures the necessary accuracy and consistency for automated high throughput systems, generating optimum signal-to-noise ratios. Using state-of-the-art manufacturing technology, we have developed a product which offers several key advantages to the end user. Optically Clear Tissue Culture Plates are assembled using unique patented laser welding technology which reduces auto fluorescence and does not inhibit cell growth. Available with 190μm polystyrene base. Available TC treated: our advanced tissue-culture (TC) treatment method evenly coats each well for optimal cell adhesion properties for highest reproducibility between wells, plates and batches. Key Features: - Leak free
- Free from DNase, RNase, human genomic DNA, and cyto-toxic
- Optimum signal-to-noise ratios
- Good cell adhesion
- Wicking and bubble formation eliminated
- SBS footprint
- Alphanumeric grid reference
- Recommended for confocal microscopy due to reduced cross-talk and superior base flatness
- Reduced auto fluorescence ensures their suitability for fluorescent assays
- Suitable for assays that measure absorbance in the visible light range (400-900nm wavelengths)
- Suitable for colorimetric assays
- Suitable for homogeneous assays
- Suitable for use in BMG lab tech, Molecular Devices, Promega Glomax and other plate readers
- Suitable for adhesive and heat sealing: our Moisture Barrier Seal 96 (4ti-0516/96) is recommended as it is optically clear and allows repeated imaging without removal, reducing contamination risks
- Available with 190μm polystyrene base
- All plates come sterilized, apart from 4ti-0224
- TC treated option available (4ti-0221)
- Available barcoded upon request
... Read More | 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and 4titude standard profile, 0.2ml polypropylene wells, polycarbonate frame, cut corner H1, working volume: <200μl, total well capacity: 300μl; universal non-skirted plate designed for use on all major thermal cyclers. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, meaning seal integrity is not compromised and less of your sample is lost through evaporation. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.2ml (200μl) working volume, 0.3ml (300μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Recommended for low volume PCR
- Compatible with standard multichannel pipettes
- Also available as a black frame with white wells for optimum signal-to-noise ratio when using fluorescent based assays
... Read More | 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12; working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block). Our FrameStar Roche Style plates are designed to achieve optimized assay 4titude low profile, 0.1ml polypropylene wells, polycarbonate frame, cut corner H12; working volume: <100μl, total well capacity: 200μl; designed for use on Roche LightCycler® 96 and 480 (with 96 well block). Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100μl. The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20μl. The semi-skirted frame allows for labeling or barcoding. Key Features: - Free from DNase, RNase, human genomic DNA, and endotoxin/pyrogen
- Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT-qPCR) results
- <0.1ml (100μl) working volume, 0.2ml (200μl) total well capacity
- Rigid polycarbonate frame for added mechanical stability
- Significantly reduced thermal expansion and sample evaporation for improved consistency in PCR results
- Improved seal integrity due to thermal stability of frame
- Alphanumeric grid reference to aid well and sample identification
- Compatible with the Roche LightCycler® 96 and 480 (with 96 well block)
- Recommended for low volume PCR
- Ideal for use with robotic systems
- Compatible with standard multichannel pipettes
- Standard plate comes with clear polypropylene wells on a clear polycarbonate frame
- Also available with white wells for optimum signal-to-noise ratio when using fluorescent based assays
- Available barcoded upon request;
- Combi packs available with qPCR Seal (4ti-0560) and (for 4ti-0951) with Optically Clear Windowed qPCR Seal (4ti-0564)
... Read More | FluidX 0.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
FluidX 0.9ml tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities - Next Generation manufacturing techniques
- Code readable without removing tubes from racks
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 96-well format SBS racks or bulk
- Sealable with screw caps/TPE septum caps
Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. Provides a lifelong and secure chain of custody for samples in biobanks, compound libraries and a broad range of biological and chemical stores, including cryogenic storage. Developed to exceed the demands of sample security, management and tracking in modern high density storage applications. Each tube features a permanent 2D code laser etched in high contrast on the tube base, a permanent 1D linear barcode and human-readable number laser etched in high-contrast on the tube side. All three codes are identical and auditing processes guarantee all three codes match; standard 2D coding option is black on white. ... Read More | Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample Featuring a novel design, the FluidX 1.6ml Maximum Recovery tube is ideally suited for automated workflows using liquid handling, where more sample can be retrieved due to the unique shaped bottom. The innovative design combines both a ?v? and ?u? shaped bottom, to enable a higher amount of sample retrieval, therefore creating a reduction in reagent wastage resulting in cost savings. Azenta Life Sciences tri-coded tubes offer unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. - Unique design with combined ?v? and ?u? shaped bottom
- Sample identification from 1D, 2D and human readable code
- Capability to work with automation, designed for liquid handlers
- Suitable for cryogenic storage
- Made from high-quality virgin PP
- Available in 48-well format SBS racks or bulk
Suitable for use with liquid handling automation, whether reformatting, cherry picking, aliquoting an/or normalization. The 1.6ml Maximum Recovery tube offers unequaled sample audit traceability, enabling sample tracking and data sharing between multiple users, labs, locations and automation capabilities. Designed and developed with broad compatibility in mind, the tubes perform without compromise in conjunction with automated barcode reading, capping and sample management systems from Azenta Life Sciences and all other industry-recognized manufacturers. ... Read More |
| Applications | High Content Screening (HCS) Assays, Drug Development, Homogeneous Assays employing Fluorescence Intensity, Colorimetric Assays, FRET and TR-FRET | PCR, qPCR, NGS | PCR, qPCR, NGS | (For research use only) Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs | (For research use only) Liquid Handling workflows, Biobanking, Cryogenic Storage, Cancer Research, Cellular and Molecular Biology, Drug Discovery, Compound Libraries, Reagent Storage, CDMOs |