| Description | The ElectroForce 5500 test instrument provides characterization and stimulation capabilities for a variety of synthetic materials such as composites and elastomers, biomaterials, tissue samples, and tissue-engineered constructs. It features a 200 N maximum force.
Key Features:The ElectroForce 5500 test instrument provides characterization and stimulation capabilities for a variety of synthetic materials such as composites and elastomers, biomaterials, tissue samples, and tissue-engineered constructs. It features a 200 N maximum force.
Key Features: - General purpose, entry-level instrument that is adaptable to a variety of test applications
- Compact size that is easily portable and fits at lab stations, in an incubator (height of 50.1 cm), or on a cart
- ElectroForce proprietary zero-friction motor that provides exceptional performance, simplicity, and efficiency
- Above & Beyond™ support that provides application expertise, unlimited technical phone support, and the only 10-year warranty in the industry
... Read More | Using proprietary ElectroForce controls and linear motor technology, the DuraPulse™ Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic PeakIQ™ control algorithms and independent test chambers ensure that Using proprietary ElectroForce controls and linear motor technology, the DuraPulse™ Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic PeakIQ™ control algorithms and independent test chambers ensure that established test conditions are maintained on each valve throughout the test. The DuraPulse HVT instrument provides testing to the ISO 5840 standard for heart valve durability assessment.
Key Features: - High frequency operation
- PeakIQ™ waveform control to prevent high pressure spikes on valve closing.
- Automatic controls (closed-loop feedback) to maintain test conditions throughout test
- Modular, independent control of each heart valve station
- Simplicity in transfer of heart valve device from durability test instrument to pulse duplicator
- 2, 4, or 6-station unit
- Reliable – 10 year warranty on linear motors
... Read More | The DuraPulse™ Stent/Graft test (SGT) instrument extends the performance and reliability that ElectroForce SGTs have become known for over the past 20 years. Still utilizing proprietary high-bandwidth, low-distortion ElectroForce actuator technology to provide best-in-class performance, the The DuraPulse™ Stent/Graft test (SGT) instrument extends the performance and reliability that ElectroForce SGTs have become known for over the past 20 years. Still utilizing proprietary high-bandwidth, low-distortion ElectroForce actuator technology to provide best-in-class performance, the DuraPulse SGT incorporates a modular manifold design that allows the user to easily change out manifold and tube sets to optimize sample throughput for various stented device sizes.
Key Benefits: - Achieve highest strain and frequency combinations with closed-loop, symmetric dual-sided pulse
- Single test instrument can be optimized for device geometry and sample number with interchangeable manifold sets – 12, 8, 6, and 4 (bifurcated) mock vessel options
- Accommodates wide range of device diameters – 2 mm to 50 mm
- Conveniently measure tube strain across all tubes with optical micrometer positioning slide and 360° manifold rotation, and a tube scanning function that holds command levels and allows the laser to be repositioned during testing
- Select from 3 ID/OD Strain Calculation modes including Zero Strain or Zero Stress Conditions (as defined by ISO 25539-2)
- Automate test pressure control with optional Pressure Control Accessory (PCA)
- Clearly identify system operation state with System Status Indicator (SSI) lights
- Instrument reliability for years of use supported by industry leading 10 year actuator warranty
- Meets or exceeds international testing standards such as ISO 25539-2 and ASTM F2477
... Read More | The ElectroForce® 3200 Series III test instruments feature a 225 N (450 N optional) maximum force. With the versatility of static to 300 Hz frequency response, the table-top configuration is adaptable to a variety of biomedical research and engineered materials test applications, including torsion The ElectroForce® 3200 Series III test instruments feature a 225 N (450 N optional) maximum force. With the versatility of static to 300 Hz frequency response, the table-top configuration is adaptable to a variety of biomedical research and engineered materials test applications, including torsion testing, creep under dynamic loading and special environments (hot/cold chambers).... Read More | TA Instrument’s Multi-Specimen Fatigue Instruments are designed to accelerate fatigue studies for a variety of materials, subcomponents and complete devices. With the capability of simultaneously testing up to 16 specimens at up to 100 Hz, users can generate S/N curves faster and with higher TA Instrument’s Multi-Specimen Fatigue Instruments are designed to accelerate fatigue studies for a variety of materials, subcomponents and complete devices. With the capability of simultaneously testing up to 16 specimens at up to 100 Hz, users can generate S/N curves faster and with higher statistical confidence levels than ever before. In this system, proven and refined technologies come together to quickly and confidently deliver results.
Features : - Simultaneous axial fatigue of 16 specimens
- Unparalleled durability and dynamic performance with the patented ElectroForce linear motor technology
- Accelerated testing frequencies up to 100 Hz with unparalleled displacement amplitudes
- Nanometer resolution and 5 micron accuracy displacement sensor
- Independent force measurement for each specimen for real-time independent specimen failure detection
- Individual precision adjustment and locking mechanisms for each specimen
- Auto-fill fluid bath for convenience and stable temperature control from ambient to 45 °C
- Integrated overtravel stop for reliable specimen protection
- Complete visibility of all 16 specimen for easy optical measurements
... Read More |