| Description | ElectroForce TestBench configurations were designed with component testing in mind, and thanks to their modular approach, a wide array of configurations and performance capabilities are possible. These instruments can be configured with 200N, 400N, or 3kN ElectroForce linear motors mounted on a ElectroForce TestBench configurations were designed with component testing in mind, and thanks to their modular approach, a wide array of configurations and performance capabilities are possible. These instruments can be configured with 200N, 400N, or 3kN ElectroForce linear motors mounted on a horizontal baseplate and include multi-channel and multi-axis options.... Read More | Using proprietary ElectroForce controls and linear motor technology, the DuraPulse™ Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic PeakIQ™ control algorithms and independent test chambers ensure that Using proprietary ElectroForce controls and linear motor technology, the DuraPulse™ Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic PeakIQ™ control algorithms and independent test chambers ensure that established test conditions are maintained on each valve throughout the test. The DuraPulse HVT instrument provides testing to the ISO 5840 standard for heart valve durability assessment.
Key Features: - High frequency operation
- PeakIQ™ waveform control to prevent high pressure spikes on valve closing.
- Automatic controls (closed-loop feedback) to maintain test conditions throughout test
- Modular, independent control of each heart valve station
- Simplicity in transfer of heart valve device from durability test instrument to pulse duplicator
- 2, 4, or 6-station unit
- Reliable – 10 year warranty on linear motors
... Read More | The DMA 3200 features patented ElectroForce linear motor technology enabling a single instrument to deliver unequalled performance and data accuracy. This unique motor technology combines powerful rare-earth magnets with a frictionless flexural suspension for the most precise force and displacement The DMA 3200 features patented ElectroForce linear motor technology enabling a single instrument to deliver unequalled performance and data accuracy. This unique motor technology combines powerful rare-earth magnets with a frictionless flexural suspension for the most precise force and displacement control over a wide range of frequencies and amplitudes. The DMA 3200 motor delivers a force output of up to 500 N and controlled displacements ranging from 1 micron to 13 mm. Testing can be conducted in both static and dynamic modes.
In addition, the frictionless, moving-magnet design eliminates failure points that exist in other motor designs, such as moving wires and bearing degradation. This ensures the most durable and reliable performance; proven over billions of cycles through decades of maintenance-free use in ElectroForce fatigue test instruments. It is the only motor in the industry backed by a ten-year warranty.
This efficient, quiet, and lubrication-free motor technology allows the DMA 3200 to be used virtually anywhere; from lab to production floor, or from the cleanroom to office space.
Key Features: - Patented, linear motor and high-resolution displacement sensor provides unmatched control over the widest ranges of force, displacement, and frequency, for superior data accuracy
- Ultra-durable, frictionless motor, backed by industry’s only ten-year warranty, provides maintenance- and worry-free operation
- High force of 500 N enables testing of larger samples or final parts under real-world conditions, by achieving higher loading levels in both DMA and fatigue analysis
- Forced Convection Oven (FCO) provides superior control and responsiveness over a temperature range of -150°C to 600°C for the highest degree of accuracy and flexibility in experiment thermal profiles
- Large Sample Oven (LSO), with a temperature range of -150°C to 315°C, offers spacious interior dimensions to accommodate testing of large samples or components
- Air Chiller Systems (ACS) offer unique gas flow cooling for sub-ambient testing without the use of liquid nitrogen, eliminating potential laboratory hazards while providing an incredible return on investment
- Broad range of fixtures accommodate a wide range of sample sizes and geometries adding to testing versatility
- Extremely rigid test frame and air bearings ensure the most accurate results on samples of very high stiffness
- Multi-color status lights provide clear and visible indication of instrument and test status
- WinTest® and TRIOS Software packages provide powerful and easy-to-use instrument control and data analysis for the ultimate flexibility in experimental design
... Read More | The ElectroForce® 3200 Series III test instruments feature a 225 N (450 N optional) maximum force. With the versatility of static to 300 Hz frequency response, the table-top configuration is adaptable to a variety of biomedical research and engineered materials test applications, including torsion The ElectroForce® 3200 Series III test instruments feature a 225 N (450 N optional) maximum force. With the versatility of static to 300 Hz frequency response, the table-top configuration is adaptable to a variety of biomedical research and engineered materials test applications, including torsion testing, creep under dynamic loading and special environments (hot/cold chambers).... Read More | ElectroForce 3500 test instruments are available in three base system configurations. The 3510 instrument, rated at 7.5 kN, is configured with the linear motor installed in the upper crosshead, making it well-suited for applications requiring a temperature-controlled bath. The 3520 instrument is ElectroForce 3500 test instruments are available in three base system configurations. The 3510 instrument, rated at 7.5 kN, is configured with the linear motor installed in the upper crosshead, making it well-suited for applications requiring a temperature-controlled bath. The 3520 instrument is rated at 7.5 kN, and the linear motor is installed in the lower baseplate. The 3550 instrument is a higher-force configuration rated at 15 kN.
Features: - Versatility for a variety of mechanical fatigue and dynamic characterization tests
- Can perform tests over a wide frequency range
- Air-cooled, clean-room compatible and quiet operation
- Optional 49 Nm or 70 Nm torsional motor is available for multi-axial test applications.
... Read More |