| Description | Es Taq DNA Polymerase is an optimized mixed enzyme of Taq and Pfu DNA Polymerase, with 5 '→ 3' DNA polymerase activity, 5 '→ 3' exonuclease activity, and 3 '→ 5' exonuclease activity. Compared with Taq DNA Polymerase, Es Taq DNA Polymerase has excellent performance of high Es Taq DNA Polymerase is an optimized mixed enzyme of Taq and Pfu DNA Polymerase, with 5 '→ 3' DNA polymerase activity, 5 '→ 3' exonuclease activity, and 3 '→ 5' exonuclease activity. Compared with Taq DNA Polymerase, Es Taq DNA Polymerase has excellent performance of high amplification efficiency and low mismatch rate, and can efficiently amplify DNA fragments. Most of the PCR products amplified with this product contain an "A" base at the 3 'end, which can be directly used for T/A cloning. This product is suitable for conventional PCR reactions and gene cloning reactions that require high fidelity. E665597Component500 UStorageE665597AEs Taq DNA Polymerase, 5 U/µL 100 µL -20℃. Avoid freeze/thaw cycle.E665597B10×PCR Buffer 1.8 mL -20℃. Avoid freeze/thaw cycle.Activity definition:Using activated salmon sperm DNA as a template/primer, the amount of enzyme required to incorporate 10 nmol of deoxyribonucleotide into acidic insoluble substances is defined as 1 active unit (U) at 74 ℃ for 30 minutes.Quality control:After multiple column purifications, SDS-PAGE detected a purity of over 99%; No exogenous nuclease activity detected; PCR method for detecting residual DNA without host; Can effectively amplify single copy genes in the human genome; Store at room temperature for one month without significant changes in activity.1. PCR reaction system Reagent 50 µlReaction system Final concentration 10×PCR Buffer 5 µL 1× dNTP Mix,10 mM each 1 µL 200 µM each Forward Primer,10 µM 2 µL 0.4 µM Reverse Primer,10 µM 2 µl 0.4 µM Template DNA <0.5 µg <0.5 µg/50 µl Es Taq DNA Polymerase,5 U/µl 0.25-0.5 µl 1.25-2.5U/50 µl ddH2O up to 50 µL /Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system. 2. PCR reaction conditions Step Temperature Time / Pre denaturation 94℃ 2 min / Denaturation 94℃ 30 s 25-35 cycles Anneal 55-65℃ 30 s 25-35 cycles Extend 72℃ 30 s 25-35 cycles Finally extended 72℃ 2 min / Attention:1) In general experiments, if the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time should be set according to the size of the amplified fragment. The amplification efficiency of Es Taq DNA Polymerase in this product is 2 kb/min.3) The number of cycles can be set based on the downstream application of the amplification product. If the number of cycles is too small, the amplification amount is insufficient; If there are too many cycles, the probability of mismatches will increase, and non-specific backgrounds will be severe. So, while ensuring product yield, the number of cycles should be minimized as much as possible... Read More | Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new high efficient fast DNA Polymerase, Mg2+, dNTPs, and PCR stabilizers and enhancers at 2× concentration. It is a new rapid DNA polymerase developed by CombiSigma with high amplification speed and stability. The extension speed is up to 5 s/kb, and the PCR can be completed in as little as 15 minutes, while longer fragments (>3 kb) or complex templates can be extended at a speed of 10-30 s/kb or a higher number of cycles. The unique MasterMix formula makes the whole reaction system very stable, while complex templates can be amplified effectively, and more than 98% of PCR amplification can be successful in one run. Simply add the DNA template and primers and top up with water to minimize human error, contamination and time.The dye (blue) has been added to the product and it is ready for electrophoretic detection at the end of the reaction. The PCR product is amplified with an 'A' base at the 3′ end and can therefore be used directly for T/A cloning and is suitable for use in the CombiVerge Seamless Cloning Kit, T4 Ligation Kit and sensory products.This product is mainly suitable for ultra-fast PCR, complex templates, complex secondary structures, gene cloning and large-scale genetic testing that requires high fidelity. quality control No exogenous nuclease activity was detected; no host residual DNA was detected by PCR; single-copy genes in various genomes could be amplified efficiently. UsageThe following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template, which should be improved and optimized according to the template, primer structure and size of the target fragment in actual operation.PCR reaction system Note: Please use the final concentration of 0.1-1.0 µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the primer concentration can be increased; if a non-specific reaction occurs, the primer concentration can be decreased to optimize the reaction system.PCR reaction conditions Note: 1) Note: For simple templates, the pre-denaturation time can be controlled at 30 s-1 min, for complex templates such as bacterial fluids, the pre-denaturation time can be increased to 2 min.Optimization of parameter settings 1. Template DNA amount setting:Excessive amounts of template may result in non-specific amplification or smear. The recommended amount of template DNA in a 50 µl PCR reaction system is as follows:-Human genomic DNA 5 ng-500 ng-Escherichia coli genomic DNA 50 pg-100 ng-plasmid DNA 10 pg-1 ng 1. 30-35 number of cycles2. Primer concentration setting: The primer concentration can be set between 0.1 µM and 1.0 µM. A low primer concentration may result in low amplification products. Too high a primer concentration will inhibit specific amplification and may result in non-specific amplification.3. Annealing temperature setting: In general, the annealing temperature is 5℃ lower than the melting temperature of amplification primer Tm, so the annealing temperature can be lowered appropriately when the desired amplification efficiency cannot be obtained; the annealing temperature can be raised appropriately when non-specific reaction occurs. For complex templates, it is necessary to adjust the annealing temperature to achieve efficient amplification.4. Extension time setting: The extension time should be set according to the size of the amplified fragments. The following extension times are recommended: simple templates such as plasmids: 5-15 s/kb; regular genomes, cDNA templates: 10-15 s/kb; complex templates, crude templates: 20-30 s/kb; (the extension time should not be too short and should be at least 5 s/kb, but should not exceed 30 s/kb).5. Number of cycles: The number of cycles can be set according to the downstream application of the amplified product. If the number of cycles is too low, the amount of amplification will be insufficient; if the number of cycles is too high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield... Read More | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | Inquire |