| Description | • A unique collection of 827 endogenous bioactive compounds for high-throughput, high content screening• Used for metabolomics and metabolism related research• Research on metabolic diseases in the human body, explore the pathogenesis of diseases such as tumors, and find effective • A unique collection of 827 endogenous bioactive compounds for high-throughput, high content screening• Used for metabolomics and metabolism related research• Research on metabolic diseases in the human body, explore the pathogenesis of diseases such as tumors, and find effective tools for finding new drugs• Diverse structures, significant pharmacological effects, and good cell permeability• Have comprehensive and detailed structural descriptions, target information, IC50 values, and customer feedback data• NMR, HPLC and other detection techniques ensure the correct structure and high purity of the productProduct Details Formulation 713 compounds pre-dissolved in 10mM DMSO,99 compounds pre-dissolved in 10mM H2O,13 compounds pre-dissolved in 2mM DMSO,2 compounds pre-dissolved in 2mM H2O Container 96 Well Format Sample Storage Tube With Screw Cap and Optional 2D Barcode Stability 12 months -20°C in DMSO 24 months -80°C in DMSO Shipping Blue ice or dry ice Human Endogenous Metabolite Compound Library Composition... Read More | Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new high efficient fast DNA Polymerase, Mg2+, dNTPs, and PCR stabilizers and enhancers at 2× concentration. It is a new rapid DNA polymerase developed by CombiSigma with high amplification speed and stability. The extension speed is up to 5 s/kb, and the PCR can be completed in as little as 15 minutes, while longer fragments (>3 kb) or complex templates can be extended at a speed of 10-30 s/kb or a higher number of cycles. The unique MasterMix formula makes the whole reaction system very stable, while complex templates can be amplified effectively, and more than 98% of PCR amplification can be successful in one run. Simply add the DNA template and primers and top up with water to minimize human error, contamination and time.The dye (blue) has been added to the product and it is ready for electrophoretic detection at the end of the reaction. The PCR product is amplified with an 'A' base at the 3′ end and can therefore be used directly for T/A cloning and is suitable for use in the CombiVerge Seamless Cloning Kit, T4 Ligation Kit and sensory products.This product is mainly suitable for ultra-fast PCR, complex templates, complex secondary structures, gene cloning and large-scale genetic testing that requires high fidelity. quality control No exogenous nuclease activity was detected; no host residual DNA was detected by PCR; single-copy genes in various genomes could be amplified efficiently. UsageThe following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template, which should be improved and optimized according to the template, primer structure and size of the target fragment in actual operation.PCR reaction system Note: Please use the final concentration of 0.1-1.0 µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the primer concentration can be increased; if a non-specific reaction occurs, the primer concentration can be decreased to optimize the reaction system.PCR reaction conditions Note: 1) Note: For simple templates, the pre-denaturation time can be controlled at 30 s-1 min, for complex templates such as bacterial fluids, the pre-denaturation time can be increased to 2 min.Optimization of parameter settings 1. Template DNA amount setting:Excessive amounts of template may result in non-specific amplification or smear. The recommended amount of template DNA in a 50 µl PCR reaction system is as follows:-Human genomic DNA 5 ng-500 ng-Escherichia coli genomic DNA 50 pg-100 ng-plasmid DNA 10 pg-1 ng 1. 30-35 number of cycles2. Primer concentration setting: The primer concentration can be set between 0.1 µM and 1.0 µM. A low primer concentration may result in low amplification products. Too high a primer concentration will inhibit specific amplification and may result in non-specific amplification.3. Annealing temperature setting: In general, the annealing temperature is 5℃ lower than the melting temperature of amplification primer Tm, so the annealing temperature can be lowered appropriately when the desired amplification efficiency cannot be obtained; the annealing temperature can be raised appropriately when non-specific reaction occurs. For complex templates, it is necessary to adjust the annealing temperature to achieve efficient amplification.4. Extension time setting: The extension time should be set according to the size of the amplified fragments. The following extension times are recommended: simple templates such as plasmids: 5-15 s/kb; regular genomes, cDNA templates: 10-15 s/kb; complex templates, crude templates: 20-30 s/kb; (the extension time should not be too short and should be at least 5 s/kb, but should not exceed 30 s/kb).5. Number of cycles: The number of cycles can be set according to the downstream application of the amplified product. If the number of cycles is too low, the amount of amplification will be insufficient; if the number of cycles is too high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield... Read More | Inquire | 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to light yellow liquidOdour: odourlessIncubation temperature: 20-37 °CLight sensitiveHeat sensitive 2、Requirements for storage rooms and vessels1.Keep container tightly closed.2.Keep cool. protected from light3. Do not store together with: Oxidizing agent. 4. Contaminated or leaked out substrate solution from damaged bottles should not be used anymore and has to be destroyed.5. Use isolated containers with some cool bags for transport.6. Spontaneous decay will increase the background. If stored at room temperature, the velocity of the decay will increase. Thus, both storage and transport at room temperature should be avoided. Nevertheless, the activity of the solution is not affected by storage at room temperature. The solution still works beyond the expiry date, but some applications, especially those including visual evaluation, may be hampered by increased background. 3、Effective Components and Principle of FunctionIn different buffer solutions (pH = 9.5), with supplementation if required, the effective componentpara nitrophenyl phosphate (pNPP) is dissolved. Alkaline Phosphatase transfers the phosphate residue to an acceptor. Under alkaline conditions a yellow colour occurs, resulting from the formed nitrophenol. 4、Biosafety informationThis mixture is not classified as hazardous in accordance with Regulation (EC) No 1272/2008; 5、Advantage1. Signal yield comparable to competitor ready-to-use solutions2. Broad measurement range3. Very low background signals4. Very low blank drift during long-term storage (<0.15 AU within 24 months)5. High colour stability after reaction stop with this product and other commonly used stopping solutions 6、Instruction for usageFor bottling consider the following instructions:• Work in a dust free and darkened room.• Keep the solution as cool as possible.• Avoid contact of the solutions with any metal parts• Clean all instruments and vessels very extensively.• Wear powder-free gloves during bottling.• Close the bottles immediately to minimize the influence of light and dust.• Use clean bottles that are impermeable to light made from HDPE or PP. 7、 General Instructions for the Use in Blotting Systems Only qualified laboratory staff, who are familiar with the basics of immunological methods, are allowed to use these solutions.The substrate solutions can be used in qualitative and quantitative ELISA procedures.When using 96-well microtiter plates, adding 100 µL of substrate per well after incubation and washing is recommended. After substrate incubation the reaction can be stopped and the photometric measurement can be carried out. Using higher incubation temperatures (37° C) may shorten the incubation time. The reaction can be stopped by using the special developed solution stop. The use of other commercially available stop solutions cannot safely exclude a further increase of the signal. Addition of a stopping solution does not change the general shape of the spectrum. The unstopped and the stopped solution should be measured at 405 nm and the background correction: should be measured at 620 nm... Read More | Product DescriptionEndo F1 cleaves Asparagine-linked high mannose and some hybrid oligosaccharides. Core fucosylation reduces the activity by 50 fold. Endoglycosidase F1 will hydrolyze sulfate containing high-mannose chains. It cleaves between the two N-acetylglucosamine residues in the Product DescriptionEndo F1 cleaves Asparagine-linked high mannose and some hybrid oligosaccharides. Core fucosylation reduces the activity by 50 fold. Endoglycosidase F1 will hydrolyze sulfate containing high-mannose chains. It cleaves between the two N-acetylglucosamine residues in the diacetylchitobiose core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine. In contrast, PNGase F removes the oligosaccharide intact.Molecular weight 32,000 daltonsContents60 µl aliquot of enzyme (1 U) in 20 mM Tris-HCl, pH 7.5Included with 20 µL and 60 µL pack sizes:5x Reaction Buffer – 250 mM sodium phosphate, pH 5.5Specific ActivityDefined as the amount of enzyme required to catalyze the release of N-linked oligosaccharides from 1 micromole of denatured Ribonuclease B (RNase B) in 1 minute at 37°C, pH 5.5. Cleavage is monitored by SDS-PAGE (cleaved RNase B migrates faster).FormulationThe enzyme is provided as a sterile-filtered solution in 20 mM Tris-HCl, pH 7.5StabilitySeveral days exposure to ambient temperatures will not reduce activity. Stable at least 12 months when stored properly. SpecificityEndo F1 cleaves Asparagine-linked high mannose or hybrid oligosaccharides. It cleaves between the two N-acetylglucosamine residues in the diacetylchitobiose core of the oligosaccharide, generating a truncated sugar molecule with one N-acetylglucosamine residue remaining on the asparagine. In contrast, PNGase F removes the oligosaccharide intact. Quality & PurityEndo F1 is tested for contaminating protease as follows: 10 µg of denatured BSA is incubated at 37°C for 24 hours with 2 µl of enzyme. SDS-PAGE analysis of the treated BSA shows no evidence of degradation. The production host strain has been extensively tested and does not produce any detectable glycosidases.Directions for use1. Add up to 200 µg of glycoprotein to an Eppendorf tube. Adjust to 38 µl final volume with de-ionized water.2. Add 10 µl 5x Reaction Buffer 5.53. Add 2.0 µl of Endo F1 to the reaction. Incubate 1 hour or more at 37°C.Monitor cleavage by SDS-PAGE... Read More |