| Description | Product contentG665762Component5 mLStorageG665762A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665762B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665762CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionGoldStar Probe Mixture Product contentG665762Component5 mLStorageG665762A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665762B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665762CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionGoldStar Probe Mixture is a premixed system for real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs and Mg2+, which is easy and convenient to operate. It is mainly used for genomic DNA target sequence and RNA reverse transcription post-cDNA target sequence detection, such as gene expression analysis, copy number analysis, SNP genotype analysis, etc. It is suitable for fluorescence quantification by different types of probe methods. GoldStar Taq DNA Polymerase is a chemically modified, new and highly efficient hot-start enzyme, which has no polymerase activity at room temperature and effectively avoids non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95℃ for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of target genes can be obtained with this product. It is suitable for all fluorescent quantitative PCR instruments that do not require ROX as a calibration dye.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration(G665762):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665762):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665762):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix it gently by turning it up and down, avoid foaming as much as possible, and use it after centrifugation for a short time.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for a long time at -20℃, protected from light. If frequent use is required in the short term, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemFinal concentration2×GoldStar Probe Mixture25 µl1×Forward Primer,10 µM1 µl0.2 µM ¹⁾Reverse Primer,10 µM1 µl0.2 µM ¹⁾Probe,10 µM1 µl0.2 µM ²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1 ×ddH₂Oup to 50 µlNote: 1) Usually, the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration during the actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50× Low ROX or 50× High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR::Note: 1) The hot-start enzyme used in this product shall be activated by the enzyme under the condition of pre-denaturation 95℃ and 10min.(2) It is recommended to use two-step PCR reaction program, if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification, and the annealing temperature, please use the range of 56 ℃ - 64 ℃ as a setting reference... Read More | EPOCROSTM is a reactive polymer with an oxazoline group on the side chain and is used as a cross-linking agent for water-based resins. Among the water-based polymers developed to address environmental issues and the increasing use of water-based products due to VOC regulations and desolventing, the EPOCROSTM is a reactive polymer with an oxazoline group on the side chain and is used as a cross-linking agent for water-based resins. Among the water-based polymers developed to address environmental issues and the increasing use of water-based products due to VOC regulations and desolventing, the EPOCROSTM WS series is a “water-soluble type” with the following structure.Features and PropertiesHigher reactivity than water-based epoxy, melamine, blocked isocyanateVOC free (EPOCROS™ WS-300 and EPOCROS™ WS-700)High crosslinking density with a small amount addedOne-pack type with long usage timeImproves water resistance, solvent resistance, heat resistance, and the strength of films, etc.Adhesion-imparting possible to PET, OPP, PVC, etc.Fast dryingLow toxicity (Ames Test: Negative, Primary Skin Irritation Test: No irritation)WS Series Product LineupApplicationsNonwoven fabric bindersPigment printingCoatings (metals, films, leather)Paint and coatings, Primers (plastics, building materials, vehicles)AdhesivesMethodASSAY for Product Code DILW:One unit equals a decrease in absorbance of 1.0 per minute at 25°C at pH 7.5 with 2,6-dichlorophenolindophenol as the chromogen.Reagents0.2 M Tris⋅HCl buffer, pH 7.50.006 M NADH. Prepare fresh daily.0.0012 M Dichlorophenolindophenol (DCPIP) Prepare fresh daily.EnzymePrepare a 10 mg/ml solution of enzyme in 0.2 M Tris⋅HCl, pH 7.5.Dilute further immediately before use to give ΔA/min of 0.15-0.20.ProcedureAdjust spectrophotometer to 600 nm and 25°C.Pipette into cuvettes as follows:Mix quickly and measure the decrease in absorbance at 600 nm for 2-3 minutes.Determine the ΔA/min. from the initial linear portion of the curve. (Use portion of curve from t=0 to t=1 minute; the rate is linear for 1/2 to 1 minute.)Calculation... Read More | Gly-Pro-pNA hydrochloride is a dipeptidyl peptidase inhibitor that inhibits dipeptidyl peptidase II, dipeptidyl peptidase IV and dipeptidyl peptidase IX | Biochemical Test:SDS-PAGE (purity > 80%); Western blot with patient sample.Calculated Isoelectric Point:pH 5.68 | Purity>97% by SDS-PAGE and HPLC analyses.FunctionPlays an important role in the organization of the cytoskeleton (By similarity). Binds to and sequesters actin monomers (G actin) and therefore inhibits actin polymerization. Seraspenide inhibits the entry of hematopoeitic pluripotent stem cells Purity>97% by SDS-PAGE and HPLC analyses.FunctionPlays an important role in the organization of the cytoskeleton (By similarity). Binds to and sequesters actin monomers (G actin) and therefore inhibits actin polymerization. Seraspenide inhibits the entry of hematopoeitic pluripotent stem cells into the S-phase... Read More |