| Description | Store at -20°C. Store under desiccating conditions. The product can be stored for up to 12 months | Inquire | Biochemical Test:SDS-PAGE (purity > 80%); Western blot with patient sample.Calculated Isoelectric Point:pH 8.38 | This product is a mixture of fast reverse transcription reagents. The 5 x EasyQuick RT MasterMix contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including EasyQuick RT Reversase, RNase Inhibitor, Random 6 mers, Oligo dT Primer, dNTP, EQ-RT BufferThis product is a mixture of fast reverse transcription reagents. The 5 x EasyQuick RT MasterMix contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including EasyQuick RT Reversase, RNase Inhibitor, Random 6 mers, Oligo dT Primer, dNTP, EQ-RT Buffer, etc. The reverse transcription efficiency of this product is high, and it can perform a good reverse transcription reaction on a small amount of RNA templates. The fluorescence quantitative template cDNA first strand synthesis can be completed in 15 minutes. This reagent kit is very convenient and fast to operate, and only RNA templates and water need to be added for reverse transcription reaction, making it particularly suitable for high-throughput detection.E665905Component200 TStorageE665905A5×EasyQuick RT MasterMix 400 µL-20℃. Avoid freeze/thaw cycle.E665905BRNase-Free Water 2×1 mL-20℃. Avoid freeze/thaw cycle. Product features1. Convenience: The ready to use reverse transcription Mix only requires the addition of RNA templates and water to initiate the reaction.2. Fast: Complete cDNA first strand synthesis in 15 minutes.3. High reverse transcription efficiency: The reverse transcription efficiency is above 90%.4. High sensitivity: PG level templates can also obtain high-quality cDNA.5. Read through complex templates: templates with high GC content and complex secondary structures.Matters needing attention1. During the operation, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended that operators wear masks and disposable gloves, frequently change gloves, and use specialized instruments and consumables.2. The reverse transcription system is prepared on ice for operation to prevent RNA degradation. The MasterMix of the reagent kit should be stored at -20 ℃ as soon as possible after use, and repeated freeze-thaw should be avoided as much as possible.3.10 µ The reaction system can be used up to 1 µ G Total RNA, if the amount of template RNA is greater than 1 µ g. Please expand the reaction system proportionally.4. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65 ℃ for 5 minutes on ice before proceeding with the next step, followed by brief centrifugation.Operation steps1. Thaw the template RNA on ice; After thawing the components of the reagent kit at room temperature, immediately place them on ice. Before use, vortex shake and mix each solution, and centrifuge briefly before use.2. Prepare the reaction system according to the following table (please prepare the reaction solution on ice), vortex shake and mix well, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube. Reagent 10 µl Reaction system Final concentration RNA Template X µl 1 pg~0.5 µg ¹⁾ 5×EasyQuick RT MasterMix ²⁾ 2 µl 1× RNase-Free Water up to 10 µl /Attention:1) If the total RNA content is greater than 1 µ g, please expand the reaction system proportionally.2) 5 x EasyQuick RT MasterMix contains Oligo (dT), Random Prime, RNase Inhibitor, dNTP Mixture, EQ-RT Buffer, etc. 3. Incubate at 37 ℃ for 15 minutes. 4. Incubate at 85 ℃ for 5 seconds to inactivate reverse transcriptase.5. After a brief centrifugation, place it on ice for subsequent experiments. If it needs to be stored for a long time, please place it at -20 ℃... Read More | Product contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a preProduct contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemreagents50µl reaction systemfinal concentration2×Fast Probe Mixture25 µl1×Forward Primer, 10µM1µl0.2µM¹⁾Reverse Primer, 10µM1µl0.2µM¹⁾Probe, 10 µM1µl0.2µM²⁾Template DNA2µl³⁾ 50x Low ROX or High ROX(optional)⁴⁾1µl1×ddH₂Oup to 50µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes to allow the starting template to fully unchain.(2) It is recommended to use two-step PCR reaction program, if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification, and the annealing temperature, please use the range of 56 ℃ - 64 ℃ as a setting reference... Read More |