| Description | Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly Product introduction:Reporter gene detection is an important tool for analyzing the interaction between potential cis elements (such as promoters, enhancers and silencers) and trans acting factors in the flanking region of structural genes in the field of modern molecular biology. Firefly luciferase is widely used in gene regulation and drug screening. Firefly luciferase is a protein with a molecular weight of about 61 KD. In the presence of ATP, magnesium ions and oxygen, it can catalyze the production of oxyluciferin from luciferin. In the process of luciferin oxidation, it will produce a light signal. The optical signal of this kit is a kind of instantaneous light, which needs to be detected immediately after adding the working solution. The half-life of optical signal is about 5 min.Instruction:1.Working fluid configuration ( 1 ) Restore all components to room temperature. ( 2 ) The component B ( stock solution ) was fully diluted with component A to prepare a 0.2 mg / mL firefly luciferase working solution, which was vortexed and shaken to ensure full mixing. Note : The firefly luciferase working solution cannot be repeatedly frozen and thawed. If the dosage of a single experiment is small, it is recommended to subpackage according to a single dosage. At room temperature, the activity decreased by about 10 % after the working solution was configured for 3 h, and the activity decreased by about 25 % after 5 h. 2.chemiluminescence value detection ( 1 ) The cell culture plate was taken out from the incubator and incubated at room temperature for 20 min to restore it to room temperature ( 22-25 ° C ). ( 2 ) Add the same volume of firefly luciferase working solution with the medium to the culture plate and mix well. ( 3 ) Incubation at room temperature for 5 min. Note : The incubation time can be adjusted according to cell type and cell number. ( 4 ) The values were read by multifunctional microplate reader or chemiluminescence instrument ( instrument parameters : the determination time was 10 s, the determination interval was 2 s ).Matters needing attention:1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. the strongest wavelength of bioluminescence catalyzed by firefly luciferase is 560 nm. 3. to prevent interference between holes, it is recommended to use white opaque orifice plate.Recommendation:Component B is recommended to use sterile water in advance to configure 2 mg / mL storage solution, A component and B component configured as storage solution, and small batch packaging according to the experimental requirements. The detection working fluid is recommended to be used now to avoid repeated freezing and thawing. Component:One-Step Firefly Luciferase Assay Buffer;D-Luciferin Scope of application:Mainly used for ADCC detection... Read More | Inquire | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | Inquire | Inquire |