| Description | 1、Product attributeShelf life: 36 monthsMarker enzyme: Horseradish peroxidase (HRP)Reaction time:short (up to 20 minutes) at 20-25°CLot-to-lot variation:< 10 %Boiling point : 100℃(Calculated flash point)Flash point::120 °C (1、Product attributeShelf life: 36 monthsMarker enzyme: Horseradish peroxidase (HRP)Reaction time:short (up to 20 minutes) at 20-25°CLot-to-lot variation:< 10 %Boiling point : 100℃(Calculated flash point)Flash point::120 °C (Calculated flash point)pH-Value (at 20 °C): 4.5-4.9 (Experimental data)Density (20℃) : 1.0064 g/cm³Water solubility: easily solubleAppearance: colourless liquidOdour: odourlessLight sensitiveHeat sensitive2、Requirements for storage rooms and vessels1.Keep container tightly closed.2.Keep cool. Protect from sunlight.3.Keep/Store only in original container.4.Never return spills in original containers for reuse.5. Keep away from: Food and feedingstuffs.6. The solution can be transported at room temperature, but temperatures exceeding 30 °C have to be avoided. Shipping should be completed within one week.7. The solution will still work beyond the expiry date, but a lower sensitivity has to be taken into account and a precipitate may occur.8. Contaminated or leaked out substrate solution from damaged bottles should not be used and has to be destroyed.3、Effective Components and Principle of FunctionA citrate buffer system (pH 4.5 - 5.0) contains the following effective components:Hydrogen peroxide3,3`,5,5`-Tetramethylbenzidine (TMB)precipitating reagentPeroxidase catalyses the decomposition of hydrogen peroxide, taking electrons from TMB (byoxidation). Oxidation of TMB forms a radical cation that stabilizes by dimerisation and shows the typical blue colour. This blue cation is stabilized by forming an insoluble complex with the precipitating reagent. So at positions with horseradish peroxidase activity a blue precipitate will appear. This precipitate is very fine so that even the smallest dots can be coloured regularly.4、Biosafety informationThis mixture is not classified as hazardous in accordance with Regulation (EC) No 1272/2008;Hazardous components:none (according to Regulation (EC) No 1907/2006 (REACH))5、Advantage1. Rapid precipitation2. Strong adherence to plastic surfaces3. Short reaction time4. Intensive dark blue colour5. Homogeneous staining pattern6、Instruction for usageFor bottling consider the following instructions:•Work in a dust free and darkened room.• Pay attention that the solution has no contact with metal parts (leading to catalysis) of yourinstruments. Closed systems of silicon tubes are favoured.• Clean all instruments and vessels very carefully.• Never touch parts of the instruments that are in contact with the solution with the naked hand. Wear powder free gloves.• Close the bottles immediately to minimize the influence of light and dust.• Use bottles that are not permeable to light, made from HDPE or PP.7. General Instructions for the Use on Microchips• This solution should only be used by qualified laboratory staff familiar with the basics of immunological methods.• Note: The substrate solution is very sensitive to impurities. This is why you should never immerse pipette tips in storage bottles. Unused solution is never returned to the bottle! Don't swap the bottles for the cups!• Substrate Solutions Test systems for instrumental measurements on glass or plastic surfaces (polycarbonate or polystyrene).• Depending on the system, it may be sufficient to wash the microarrays after incubation with the conjugate and then cover them with the substrate solution. Arrays can be developed with a rocking motion until visible color appears (approximately 5 to 10 minutes). Measurements can be performed using wet arrays or after washing with distilled water and drying. Dry microchips can be used for recording purposes. (Note: some glues will destroy colored deposits)... Read More | Product contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a preProduct contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemreagents50µl reaction systemfinal concentration2×Fast Probe Mixture25 µl1×Forward Primer, 10µM1µl0.2µM¹⁾Reverse Primer, 10µM1µl0.2µM¹⁾Probe, 10 µM1µl0.2µM²⁾Template DNA2µl³⁾ 50x Low ROX or High ROX(optional)⁴⁾1µl1×ddH₂Oup to 50µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes to allow the starting template to fully unchain.(2) It is recommended to use two-step PCR reaction program, if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification, and the annealing temperature, please use the range of 56 ℃ - 64 ℃ as a setting reference... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | Purity:>95%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:HSPD1, also known as HSP60, is a member of the chaperonin family. HSPD1 may function as a signaling molecule in the innate immune system. This protein is essential for the folding and assembly of newly Purity:>95%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:HSPD1, also known as HSP60, is a member of the chaperonin family. HSPD1 may function as a signaling molecule in the innate immune system. This protein is essential for the folding and assembly of newly imported proteins in the mitochondria. It may also prevent misfolding and promote the refolding and proper assembly of unfolded polypeptides generated under stress conditions in the mitochondrial matrix. HSPD1 gene is adjacent to a related family member and the region between the 2 genes functions as a bidirectional promoter. Several pseudogenes have been associated with this gene. Mutations associated with this gene cause autosomal recessive spastic paraplegia 13. Defects in HSPD1 are a cause of spastic paraplegia autosomal dominant type 13 (SPG13). Spastic paraplegia is a degenerative spinal cord disorder characterized by a slow, gradual, progressive weakness and spasticity of the lower limbs. Defects in HSPD1 are the cause of leukodystrophy hypomyelinating type 4 (HLD4); also called mitochondrial HSP60 chaperonopathy or MitCHAP-60 disease. HLD4 is a severe autosomal recessive hypomyelinating leukodystrophy. HSPD1 is clinically characterized by infantile-onset rotary nystagmus, progressive spastic paraplegia, neurologic regression, motor impairment, profound mental retardation. Death usually occurs within the first two decades of life... Read More | Recombinant Human Serum Albumin (rHSA) is an active compound and possesses an identical conformation to plasma derived HSA. Recombinant Human Serum Albumin (rHSA) has no difference between rHSA and plasma derived HSA. Recombinant Human Serum Albumin (rHSAAppearance:SolidBiological Activity:Recombinant Human Serum Albumin (rHSA) is an active compound and possesses an identical conformation to plasma derived HSA. Recombinant Human Serum Albumin (rHSA) has no difference between rHSA and plasma derived HSA. Recombinant Human Serum Albumin (rHSAAppearance:SolidBiological Activity:Recombinant Human Serum Albumin (rHSA) is an active compound and possesses an identical conformation to plasma derived HSA. Recombinant Human Serum Albumin (rHSA) has no difference between rHSA and plasma derived HSA. Recombinant Human Serum Albumin (rHSA... Read More |