| Description | EnzymoPure™M-MuLV Reverse Transcriptase (RNase H-) is an optimized Moloney Murine Leukemia Virus (M-MuLV) reverse transcriptase without ribonuclease H (RNase H) activity. It is a DNA polymerase that uses single stranded RNA or DNA as template to synthesize complementary DNA strands in the EnzymoPure™M-MuLV Reverse Transcriptase (RNase H-) is an optimized Moloney Murine Leukemia Virus (M-MuLV) reverse transcriptase without ribonuclease H (RNase H) activity. It is a DNA polymerase that uses single stranded RNA or DNA as template to synthesize complementary DNA strands in the presence of primers. Different from common M-MuLV reverse transcriptase, the EnzymoPure™M-MuLV Reverse Transcriptase (RNase H-) lacks RNase H activity, and does not degrade the RNA strand of an RNA-DNA hybrid, thus facilitating the synthesis of long cDNA. EnzymoPure™M-MuLV reverse transcriptase (RNase H-) is one of the most widely used reverse transcriptase for synthesizing cDNA.FeaturesApplication:First strand cDNA synthesis using total RNA or mRNA as template; DNA probe labeling; RNA analysis by primer extension; fluorescent probe labeling for DNA microarray analysis.Source:Recombinant protein expressed in E. coli. The RT M-MuLV reverse transcriptase (RNase H-) is encoded by the mutation-optimized pol gene encoding M-MuLV reverse transcriptase.Enzyme activity: One unit of the enzyme incorporates 1nmol of dTMP into a polynucleotide fraction in 10min at 37℃. Enzyme activity is assayed in 50mM Tris-HCl (pH8.3), 6mM MgCl2, 10mM DTT, 40mM KCl, 0.5mM dTTP, 0.4MBq/ml [3H]-dTTP, 0.4mM poly(A)•oligo(dT)12-18.Purity: Free from DNA endonuclease, DNA exonuclease, phosphoesterase and RNase.Storage buffer: 50mM Tris (pH8.3), 100mM NaCl, 1mM EDTA, 5mM DTT, 0.1% Triton X-100 and 50% glycerol.Reaction Buffer (5X): 250mM Tris (pH8.3 at 25℃), 250mM KCl, 20mM MgCl2, 50mM DTT.Inactivation or inhibition:RT M-MuLV Reverse Transcriptase (RNase H-) can be inactivated by incubation at 70℃ for 10 minutes, or inhibited by EDTA, EGTA, inorganic phosphates, pyrophosphates and polyamine.The concentration of this product is 200U/µl. When using a reaction volume of 20µl, this product is sufficient for 10 reactions.Precautions:Please refer to the instructions for reverse transcription of RNAs with high GC content.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear lab coat and disposable gloves during the operation.Instructions for Use:1. First-strand cDNA synthesisa. Set up the first-strand cDNA synthesis reaction in a nuclease-free PCR tube on ice or at room temperature as follows. RNase Inhibitor and dNTP mix can be purchased from. RNA Template (one of the three types of RNA)Total RNA0.01-5µgPoly(A) RNA/mRNA1-500ngSpecific RNA0.01pg-500ngPrimer (one of the three types of primers)Oligo(dT)18 Primer0.5µg (or 100pmol)Random Hexamer Primer0.2µg (or 100pmol)Gene-specific Primer15-25pmol(optional) For RNAs with high GC content or complex secondary structures, incubate the mixture of primer and template at 65ºC for 5 minutes, and immediately put it on ice to disrupt RNA secondary structures.DEPC-treated WaterTo 13.7µl*Reaction Buffer (5X)4µlRNase Inhibitor (40U/µl)0.5µl**dNTP Mix (25 mM each)0.8µl***RT M-MuLV Reverse 1µlTotal Volume20µl* ‘To 13.7µl’ means filling the mixture of template and primer to a total volume of 13.7µl with DEPC-treated water.** The volume of RNase Inhibitor may vary depending on the type of RNase Inhibitor used. If the volume of RNase Inhibitor is less than 0.5µl, adjust the volume of DEPC-treated water accordingly.*** The volume of dNTP mix varies depending on the concentration of dNTP stock. If the volume of dNTP is not 0.8µl, adjust the volume of DEPC-treated water accordingly.b. Mix the reaction by vortex or pipetting gently, centrifuge briefly to allow liquid to accumulate at the bottom of PCR tube.c. Incubate the reaction at 42ºC for 10-60min if Oligo(dT)18 or gene-specific primer is used. If random hexamer is used, carry out incubation at 25ºC for 10min, followed by incubation at 42℃ for 60 min. Note: For RNA template with high GC content or secondary structures, incubate the reaction at 45℃ for 60min.d. Stop the reverse transcription by incubating the reaction at 70℃ for 10min to inactivate the RT M-MuLV Reverse Transcriptase (RNase H-). Note: Heat-inactivation of reverse transcriptase is not recommended for long cDNA over 5kb, as this method may cause shearing of long cDNA fragments. In such a case, phenol-chloroform extraction or column purification can be considered.e. The reverse transcription products can be used directly for subsequent experiments such as PCR, or stored at -20℃ for future use. We recommend using 2µl reverse transcription products in a PCR reaction volume of 50µl.2. For other applications such as primer extension and probe labeling, please refer to reference related to M-MuLV reverse transcriptase (RNase H-)FAQ:1. The reverse transcription product of total RNA is invisible after electrophoresis.It is a normal phenomena, because the amount of RNA template is low, and the amount of reverse transcription products in different size is even lower. 2. No specific product can be amplified from the reverse transcription product.a. To exclude the problem of PCR reaction system or reverse transcription product, use gene-specific primers to amplify internal reference genes, such as actin and GAPDH. Reference genes can be amplified but not the target gene, indicating primers of target gene are not well designed or the expression of the target gene is too low to be detected. b. Inappropriate primer is used for reverse transcription. Random hexamer instead of Oligo(dT)18 should be used for the reverse transcription of bacterial total RNA which does not have poly(A) tails. Gene-specific primers used for reverse transcription must be well designed... Read More | Inquire | ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology experiments, such as PCR, enzyme digestion, hybridization, microarray analysis, and other molecular biology experiments.The product was quantified using NanoDrop One at a concentration of 200 ng/µL.Preparation and precautions before useLong-term storage at -20˚C is recommended. Before use, the bottle should be removed from the refrigerator and equilibrated to room temperature and centrifuged before opening the cap for use. Samples should be restored to the sealed state as soon as possible after opening.How to use (take qPCR experiment as an example)1. Amplification template preparationThe samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0,1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. The samples were placed on ice at 4°C and set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard 1 (100ng/uL) with TE to make 5 different concentrations of standards according to the table below. 10ng/µL of DNA Standard 1 (Std. 1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When not used temporarily after preparation, it should be stored at 4℃ or on ice.styleCorresponding concentration (ng/µL)Minimum dilution volume (in µL)Std.11010 [100 ng/µL DNA Standard 1] + 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationThe cryopreserved reagents to be used were completely thawed and mixed by inversion several times before preparation, and then briefly centrifuged and prepared for use. 20 µL of the base reaction system was as follows.The base reaction system for 20 µL was as follows:reagents20µL reaction system2×qPCRMix10µLPrimerMixXµLProbeMixXµLTemplate4µLddH2OMake up to 20 µLNote: High Rox model: add 1 µL of 50×High Rox per 50 µL of reaction system; Low Rox model: add 1 µL of 50×High Rox per 500 µL of reaction system.Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the manual of the instrument or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration during actual use.Prepare a sufficient amount of reaction system mixture as required. After the reaction system has been prepared and mixed thoroughly, add 16 µL per well to the reaction wells. Then add the prepared standard and diluted sample into the corresponding reaction wells, the volume of addition is 4µL/well. TE was added to the blank control tube, and the same amount of TE was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe following is an example of our GoldStar Probe Mixture reaction conditions, which should be improved and optimized according to the PCR product template, primer structure and target fragment size.movetemptimingcirculatepremutability95°C10min1denaturation95°C10sec55Annealing/Extension60°C30sec5Data analysis1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should not be lower than 0.98, and the slope should be between -3.1 and -3.6 when the Ct value is the vertical coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment... Read More | Inquire | Inquire |