| Description | Physical appearance: LiquidStorage buffer solution: GelRed dye, Stabilizer, 10mM Tris-HCl, 5mM EDTA, 0.03% Bromophenol Blue, 0.03% Xylene Cyanol, 30% Glycerol, pH7.6Product Description:1. This product is composed of 9 linear double stranded DNA fragments, ranging in size from 100bp to 10000bp, with Physical appearance: LiquidStorage buffer solution: GelRed dye, Stabilizer, 10mM Tris-HCl, 5mM EDTA, 0.03% Bromophenol Blue, 0.03% Xylene Cyanol, 30% Glycerol, pH7.6Product Description:1. This product is composed of 9 linear double stranded DNA fragments, ranging in size from 100bp to 10000bp, with sizes of 250bp and 500bp respectively 750bp, 1000bp, 1500bp, 2000bp, 3000bp, 5000bp, 10000bp. 1500bp indicates a bright band, with a concentration 2.5 times that of other bands, making it easier to observe after electrophoresis.2. This product has been saved in a 1xLoading Buffer and can be directly used for electrophoresis, making it easy to use.3. This product and its accompanying 5xLoading buffer already contain Gelred nucleic acid dye, which can be used in conjunction. After electrophoresis, it can be directly observed under UV without the need for subsequent staining treatment.4. This product is not suitable for polyacrylamide gel electrophoresis.5. Recommended concentration of electrophoresis buffer and agarose gel:1xTAE electrophoresis bufferAgarose concentration: 1.5%~2.0%,6. Using this product system, no nucleic acid dye is needed in agarose gel.instructions:1. Prepare agarose gel with appropriate concentration and without any nucleic acid dye.2. The concentration of gel has a great influence on DNA electrophoresis. The recommended concentration of agarose gel for this product is 1.5%~2.0%.3. It is recommended to use 1xTAE buffer with an electrophoresis voltage not exceeding 10v/cm.4. The commonly used 3.5mm sample well requires a recommended amount of 3-5 µ l for DNA markers, and the sample size should be appropriately increased for wide gel wells.5. Mix the sample to be tested with the matching 5xLoading buffer in a ratio of about 4:1, and then add it to the gel sampling hole.6. Electrophoretic to appropriate distance:Because Gelred is firmly bound to DNA, it can make full use of the length of gel, and the electrophoresis distance is longer, as long as the smallest segment does not run out of the gel, so as to facilitate the electrophoresis separation of small segments. Generally, the distance between the bromophenol blue indicator band and the edge of gel shall not be less than 1cm.7. After electrophoresis, observe the electrophoresis bands under ultraviolet light.8. The 5x loading buffer included in the product is used for sampling after mixing with the sample to be tested, and contains dual indicators of bromophenol blue and xylene blue.9. If there are a large number of samples that can be directly sampled and require electrophoresis detection, it is recommended to use Gelred gel method for detection without pre mixing samples, which can save a lot of experimental time... Read More | Product contentF665766Component5 mLStorageF665766A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665766BddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Product contentF665766Component5 mLStorageF665766A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665766BddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemFinal concentration2×Fast Probe Mixture25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes in order to make the starting template fully unchained.(2) It is recommended to use two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out a three-step PCR amplification, annealing temperature, please use the range of 56 ℃ - 64 ℃ for as a reference for the setting... Read More | Inquire | Extinction Coeff.A280 nm = 1.0 at 1.0 mg/mLSpecificityMonospecific for Factor B in human plasma and serumGeneral DescriptionProduct is whole polyclonal antiserum from goats immunized with highly purified human complement protein. Product is not a purified IgG fraction. Goats are maintained in FDA Extinction Coeff.A280 nm = 1.0 at 1.0 mg/mLSpecificityMonospecific for Factor B in human plasma and serumGeneral DescriptionProduct is whole polyclonal antiserum from goats immunized with highly purified human complement protein. Product is not a purified IgG fraction. Goats are maintained in FDA certified facilities.Physical Characteristics & StructureAntibodies present in the antisera are primarily IgGApplicationsWestern Blots: Effective at dilutions 1/4,000 to 1/8,000 depending on conditions.Most effective against non-reduced antigen.ELISA: Effective at dilutions 1/8,000 to 1/16,000 depending on conditions.Immunodiffusion: Effective against NHS and plasma at 1/16 dilution... Read More | Inquire |