| Description | Storage buffer: 10mM Tris HCl, 5mM EDTA, 0.03% Bromophenol Blue, 0.03% Xylene Cyanol, 30% Glycerol, pH7.6Product IntroductionThis product is composed of 9 linear double stranded DNA fragments, stored in a 1xLoading Buffer, with dense bands that require high concentration gel and low voltage Storage buffer: 10mM Tris HCl, 5mM EDTA, 0.03% Bromophenol Blue, 0.03% Xylene Cyanol, 30% Glycerol, pH7.6Product IntroductionThis product is composed of 9 linear double stranded DNA fragments, stored in a 1xLoading Buffer, with dense bands that require high concentration gel and low voltage electrophoresis. It is suitable for accurately confirming the size of DNA fragments. The size range is 50-500bp, which are 50bp, 100bp, 150bp, 200bp, 250bp, 300bp, 350bp, 400bp, and 500bp respectively; 250 bp is the bright band, with a concentration 2.5 times that of other bands; In the 5 ul product, each strip contains about 40 ng, and the highlight strip contains about 100 ng.Usage suggestions1. It is recommended to sample 5 ul and increase the sample size appropriately for wide adhesive holes.2. It is recommended to use 2.5-3.5% Agarose or 5% PAGE gel, voltage 4-10 v/cm, and 0.5xTBE buffer for electrophoresis. Pay attention to replacing the electrophoresis buffer in time and using the newly prepared gel to achieve ideal results.3. Stain with EB or other nucleic acid dyes, and observe the electrophoretic bands under UV light.matters needing attention1. This product has been saved in a 1xLoading Buffer and can be directly used for electrophoresis. It is easy to use and the electrophoresis image is clear.2. When using agarose gel containing EB for electrophoretic detection, the bromophenol blue band can be electrophoretic to about 2/3 of the distance, otherwise the small segment will become dark because EB is separated from DNA.3. The accompanying 5xLoading buffer can be used for sample detection.5x Loading Buffer components:10 mM Tris-HCl,5 mM EDTA, pH7.6, 0.03% bromophenol blue, 0.03% xylene blue, 30% glycerol Product componentD745352Component100 T500TStorageD745352ADNA Ladder (50-500bp)500 µL5× 500 µL-20℃. Avoid freeze/thaw cycle.D745352B5xLoading buffer1 mL5× 1 mL-20℃. Avoid freeze/thaw cycle... Read More | Product contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a preProduct contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemreagents50µl reaction systemfinal concentration2×Fast Probe Mixture25 µl1×Forward Primer, 10µM1µl0.2µM¹⁾Reverse Primer, 10µM1µl0.2µM¹⁾Probe, 10 µM1µl0.2µM²⁾Template DNA2µl³⁾ 50x Low ROX or High ROX(optional)⁴⁾1µl1×ddH₂Oup to 50µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes to allow the starting template to fully unchain.(2) It is recommended to use two-step PCR reaction program, if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification, and the annealing temperature, please use the range of 56 ℃ - 64 ℃ as a setting reference... Read More | GoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenientGoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenient. Mainly used for detecting genomic DNA target sequences and RNA reverse transcription cDNA target sequences, such as gene expression analysis, copy number analysis, SNP genotype analysis, etc., suitable for fluorescence quantification using different types of probe methods. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, novel and highly efficient hot start enzyme. It has no polymerase activity at room temperature, effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. The enzyme activation requires incubation at 95 ℃ for 10 minutes. The unique combination of PCR buffer system and hot start enzyme significantly improves the amplification efficiency of PCR, with stronger fluorescence signal and higher sensitivity, which can detect single copy templates. By using this product, a wider linear range can be obtained, resulting in more accurate quantification of the target gene. Suitable for all fluorescence quantitative PCR instruments that do not require ROX as a calibration dye.ROX dye is used to correct the fluorescence signal error between wells in quantitative PCR instruments, and is generally used in Real Time PCR amplification instruments from companies such as ABI and Stratagene. The excitation optical systems of different instruments vary, so the concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (CW0932): Roche LightCycle 480, Roche LightCyler 96, Bio rad iCyler iQ, iQ5, CFX96, etc.Instrument requiring Low ROX calibration (CW2625): ABI Prism7500/7500 Fast, QuantStudio ® 3 System, QuantStudio ® 5 System, QuantStudio ® 6 Flex System, QuantStudio ® 7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, etc.Instruments that require High ROX calibration (CW2626): ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.G665832Component5 mLStorageG665832A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665832BddH2O5×1 mL -20℃. Avoid freeze/thaw cycle. Notes:1. Before use, please gently mix upside down to avoid foaming, and use after briefly centrifugation.2. Avoid repeated freezing and thawing of this product, as repeated freezing and thawing may cause a decrease in product performance. This product can be stored for a long time at -20 ℃, away from light. If frequent use is required in the short term, it can be stored at 2-8 ℃.Usage:The following are examples of conventional PCR reaction systems and reaction conditions. In practical operation, corresponding improvements and optimizations should be made based on different templates, primer structures, and target fragment sizes.1. PCR reaction system Reagent 50 µl Reaction system Final concentration 2×GoldStar Probe Mixture 25 µl 1 × Forward Primer,10 µM 1 µl 0.2 µM¹⁾ Reverse Primer,10 µM 1 µl 0.2 µM¹⁾ Probe,10 µM 1 µl 0.2 µM²⁾ Template DNA 2 µl³⁾ / 50×Low ROX or High ROX(optional)⁴⁾ 1 µl 1 × ddH2O up to 50 µl / Attention:1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range.2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of DNA template is usually based on 10-100 ng genomic DNA or 1-10 ng cDNA as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the template to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.2. PCR reaction programAttention! The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes!Two step PCR Step Temperature Time / Pre denaturation 95℃ 10 min¹⁾ / Denaturation 95℃ 15 s 35-40 cycles Annealing/Extension ²⁾ 60℃ 1 min 35-40 cycles Attention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Purity: >90%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:Involved in the high-affinity maltose membrane transport system MalEFGK. Initial receptor for the active transport of and chemotaxis toward maltooligosaccharides.Epitope tagging offers an easy and universalPurity: >90%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:Involved in the high-affinity maltose membrane transport system MalEFGK. Initial receptor for the active transport of and chemotaxis toward maltooligosaccharides.Epitope tagging offers an easy and universal strategy for the identification and purification of proteins derived by recombinant DNA technology. The insertion of a Maltose Binding Protein (MBP) tag creates a stable fusion product that does not interfere with the bioactivity of the protein or with the biodistribution of the MBP tagged product... Read More | Purity>98% by SDS-PAGE and HPLC analyses.Additional sequence informationBelongs to the intercrine alpha (chemokine CxC) family.FunctionActs as a scavenger receptor on macrophages, which specifically binds to OxLDL (oxidized low density lipoprotein), suggesting that it may be involved in Purity>98% by SDS-PAGE and HPLC analyses.Additional sequence informationBelongs to the intercrine alpha (chemokine CxC) family.FunctionActs as a scavenger receptor on macrophages, which specifically binds to OxLDL (oxidized low density lipoprotein), suggesting that it may be involved in pathophysiology such as atherogenesis (By similarity). Induces a strong chemotactic response. Induces calcium mobilization. Binds to CXCR6/Bonzo.Post-translationalGlycosylated... Read More |