| Description | One unit is defined as the amount of enzyme that will incorporate 10 nmol of dNTP into acid insoluble material in 30 minutes at 74℃.Application:high-fidelity PCR amplification, point mutation, and gene cloning, etc. The amplified PCR products by Plus DNA polymerase are dA-tailed at 3One unit is defined as the amount of enzyme that will incorporate 10 nmol of dNTP into acid insoluble material in 30 minutes at 74℃.Application:high-fidelity PCR amplification, point mutation, and gene cloning, etc. The amplified PCR products by Plus DNA polymerase are dA-tailed at 3’ ends and can be directly cloned into T vectors.Definition of activity: One unit is defined as the amount of enzyme that will incorporate 10 nmol of dNTP into acid insoluble material in 30 minutes at 74℃.Purity: free of DNA endonuclease and exonuclease, phosphatase, and RNAase.Enzyme storage buffer: 20mM Tris-HCl (pH 7.5), 1mM DTT, 0.1mM EDTA, 100mM KCl, 200µg/ml BSA and 50% (v/v) glycerol.Inactivation or inhibition: Plus DNA polymerase can be deactivated by phenol chloroform extraction. Source:Recombinant hyperthermophilic archaeon Pyrococcus-like DNA polymerase expressed in E. coli.Enzyme storage buffer:20mM Tris-HCl (pH 7.5), 1mM DTT, 0.1mM EDTA, 100mM KCl, 200µg/ml BSA and 50% (v/v) glycerol.Inactivation or inhibition:Plus DNA polymerase can be deactivated by phenol chloroform extraction. Precautions:Because PCR reaction is extremely sensitive, contamination must be avoided during preparation of PCR reactions. Negative control without templates is recommended for all PCR assays to control contamination.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear a lab coat and disposable gloves during the operation.Instructions for Use:1.Prepare PCR reactions:a.Thaw PCR components at room temperature and mix well prior to use. Keep the Plus DNA polymerase on ice.b.Set up the PCR reaction on ice as follows:To amplify dsDNA 6kbReagentFinal ConcentrationVolumeFinal ConcentrationVolumeNuclease-free water-(36.5-x)µl-(29-y)µl10X Buffer (with Mg2+)1×5µl1×5µldNTP (2.5mM each)0.25mM each5µl0.5mM each10µlTemplate DNA10pg-1µg*xµl10pg-1µg*yµlPrimer mixtures (10µM each)0.2µM each1µl0.4µM each2µl DNA Polymerase2.5U/50µl1µl2.5U/50µl1µlTotal volume-50µl-50µlNote 1: When multiple reactions are required, prepare a master mix including all reagents except template and primer, and then dispense to different nuclease-free PCR tubes. Sometimes, the master mix can also include template and primer.Note 2: When amplifying fragments larger than 6kb, the amount of template should be increased appropriately, but too much template DNA can also easily lead to non-specific PCR amplification products. * The recommended amount of template varies for different types of DNA. In a reaction volume of 50µl, use 100 ng of Mammalian genomic DNA, 100 ng of E. coli genomic DNA, or 5-30 ng of Plasmid DNA. c.Mix the PCR reaction mixture by gentle vortex or pipetting. Centrifuge briefly to collect liquid at the bottom of the PCR tube. d.(Optional) When using a thermocycler without a heated lid, place a drop of mineral oil onto the top of PCR reaction mixture.2.Transfer the PCR reaction to a thermocycler and run thermocycling conditions as follows:StepTo amplify dsDNA 6kbCyclesInitial denaturation94℃ 3min94℃ 3min1Denaturation94℃ 30sec94℃ 30sec30Annealing55℃ 30sec55℃ 30secExtension68℃ 15s/kb68℃ 1min/kbFinal extension68℃ 10min68℃ 15min1Hold4℃ forever4℃ forever-Note 1: The extension temperature can also be set to 72℃, but the amplification will be slightly reduced. For DNA fragments difficult to amplify, denaturation at 92℃ and extension at 72℃ are recommended. Note 2: PCR running conditions should be adjusted based on the template, primer sequence, the length of PCR product or GC content, etc.Note 3: The optimal extension time varies depending on the amplicon length. For amplification of DNA fragments shorter than 6kb, the recommended extension time is 15 seconds per kb (e.g. use 15 seconds to amplify 1kb fragment and 30 seconds to amplify 2kb fragment). When amplifying DNA fragments longer than 6kb, the recommended extension time is 1 minute per kb (e.g., use 5 minutes to amplify 5kb fragment). Note 4: For initial PCR, the number of cycles can be set to 35 to ensure that the expected PCR product can be amplified. The number of cycles for semi-quantitative or quantitative PCR analysis must be optimized appropriately so that the PCR reaction does not reach a plateau.FAQ:1.Few PCR products or no specific bands.a.It could be due to poor design of primers. Use primer design tools for primer design to avoid inappropriate GC content, secondary structure, dimer, annealing temperature, length, specificity and other possible problems. When adding restriction enzyme cutting sites in the primer sequence, the same problems need to be considered. In the case that positive control primers work normally but not your primers, redesign primers.b.DNA to be amplified may have a high GC content. High GC genes are relatively difficult to be amplified. In such a case, GC-rich buffer suitable for amplifying DNA with high GC content can be used, and PCR reaction parameters should be adjusted accordingly. Direct addition of 1-10% DMSO or 5-20% glycerol is also helpful for amplifying fragments with high GC content.c.PCR reactions set up at room temperature tend to produce non-specific bands. It is recommended to set up PCR reactions on ice.d.The presence of secondary structure in primers, primer dimers or short primers, may result in poor annealing of primers to the target sequence. In this case, try touch down or other methods for annealing. A gradual cooling from 65℃ to 55℃ or 50℃ is usually used to make annealing more efficiently. e.The annealing temperature needs to be optimized. If necessary, use a temperature gradient to determine the optimal annealing temperature for each template-primer pair combination. f.Insufficient extension time. The extension time can be extended 2-5 times from the recommended extension time, and can be set to 5 minutes per 1kb for fragments difficult to amplify. g.Insufficient denaturation. To amplify long DNA or high GC DNA fragment, the initial denaturation temperature can be adjusted to 95℃ for 1 min or even 95℃ for 2-4 min.h.Perform PCR reactions on a different thermal cycler to avoid possible problems with the instrument.i.Insufficient number of PCR cycles. Try more PCR cycles, but do not exceed 40 cycles. j.Insufficient amount of template. Add more DNA templates or try nested PCR or secondary PCR. Nested PCR is to design another pair of PCR primers inside the original PCR primers, and then conduct PCR amplification again with the diluted first PCR product as template. Instead, secondary PCR uses the same primers for second PCR amplification with the diluted PCR product as template. Nested PCR usually can remove the non-specific DNA amplification, but secondary PCR cannot.k.DNA sample contains substances that inhibit the PCR reactions. In such a case, template DNA can be purified using appropriate DNA purification methods such as column purification.l.Use high-purity primers.m.Use high-quality dNTP mixture.n.Increase the amount of DNA polymerase appropriately.o.When non-specific products are produced, increase the annealing temperature appropriately.p.Positive and negative controls are always recommended when optimizing PCR reactions.2.Occurrence of non-specific bands or DNA smear when examined by agarose gel electrophoresis.a.Increase the annealing temperature by 2-5℃.b.Reduce the amount of DNA template.c.PCR reactions set up at room temperature tend to produce non-specific bands. It is recommended to set up PCR reactions on ice.d.Reduce the amount of Plus DNA polymerase appropriately.e.Reduce the extension time appropriately... Read More | Inquire | Inquire | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | Inquire |