| Description | EnzymoPure™ M-MuLV Reverse Transcriptase is a modified and optimized Moloney Murine Leukemia Virus (M-MuLV) Reverse Transcriptase. It is a DNA polymerase that uses RNA or DNA as template to synthesize complementary DNA strands in the presence of primers. It also has Ribonuclease H (RNase H) EnzymoPure™ M-MuLV Reverse Transcriptase is a modified and optimized Moloney Murine Leukemia Virus (M-MuLV) Reverse Transcriptase. It is a DNA polymerase that uses RNA or DNA as template to synthesize complementary DNA strands in the presence of primers. It also has Ribonuclease H (RNase H) activity, which can specifically degrade the RNA in RNA-DNA hybrids, but not single-stranded RNA or double-stranded RNA.FeaturesApplication:First strand cDNA synthesis using total RNA or mRNA as template; DNA probe labeling; RNA analysis by primer extension.Source:Recombinant protein expressed in E. coli. The RT M-MuLV reverse transcriptase is encoded by the mutation-optimized pol gene encoding M-MuLV reverse transcriptase.Enzyme Activity: One unit of the enzyme incorporates 1 nmol of dTMP into a polynucleotide fraction in 10 min at 37℃. Enzyme activity is assayed in 50 mM Tris-HCl (pH 8.3), 6 mM MgCl2, 10 mM DTT, 40 mM KCl, 0.5 mM dTTP, 0.4 MBq/ml [3H]-dTTP, 0.4 mM polyA•oligo(dT)12-18.Purity: Free of DNA endonuclease, DNA exonuclease, phosphatase, and RNase other than the RNase H enzyme activity contained in the RTTM M-MuLV Reverse Transcriptase.Enzyme storage buffer:50 mM Tris, pH 8.3, 100mM NaCl, 1 mM EDTA, 5 mM DTT, 0.1% Triton X-100 and 50% glycerol.Inactivation or inhibition:M-MuLV Reverse Transcriptase can be inactivated by incubation at 70℃ for 10 minutes, or inhibited by chelating agents including EDTA and EGTA, inorganic phosphate, pyrophosphate, and polyamine.This product is sufficient for 10 reverse transcription reactions when used in a reaction volume of 20µl.Precautions:Please refer to the instructions for reverse transcription of RNAs with high GC content.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear a lab coat and disposable gloves during the operation.Instructions for Use:1.First-strand cDNA Synthesis:a. Set up the reaction in a nuclease-free PCR tube as follows:RNA Template (one of the three types of RNA)Total RNA0.1-5µgPoly(A) RNA/mRNA10-500ngSpecific RNA0.01pg-500ngPrimer (one of the three types of primers)Oligo(dT)180.5µg (or100pmol)random hexamer0.2µg (or100pmol)Gene specific primer15-25pmol(optional) For RNAs with high GC content or complex secondary structures, incubate the mixture of primer and template at 65℃ for 5 minutes, and immediately put it on ice to disrupt RNA secondary structures.DEPC-treated Water-To 13.7µl *Reaction Buffer (5X)-4µlRNase Inhibitor-0.5µl **dNTP Mix (25 mM each)-0.8µl ***RTTM M-MuLV Reverse Transcriptase-1µlTotal Volume-20µl* ‘To 13.7µl' means filling the mixture of template and primer to a total volume of 13.7µl with DEPC-treated Water. ** The volume of RNase Inhibitor may vary depending on the type of RNase Inhibitor used. If the volume of RNase Inhibitor is not 0.5µl, adjust the volume of DEPC-treated Water accordingly.*** The volume of dNTP mix varies depending on the concentration of dNTP stock. If the volume of dNTP is not 0.8µl, adjust the volume of DEPC-treated Water accordingly.b. Mix well by vortex or pipetting gently, centrifuge briefly to collect liquid at the bottom of PCR tube.c. If using Oligo(dT)18 or gene-specific primers, incubate the reaction mixture at 42℃ for 60 minutes. If random hexamer is used, incubate at 25℃ for 10 minutes followed by 60 minutes at 42℃. Note: For RNA templates with high GC content, incubate the reaction at 45℃ for 60 minutes.d. Incubate at 70℃ for 10 minutes to stop the reaction. Note: Heat-inactivation of reverse transcriptase is not recommended for long cDNA over 5kb, as this method may cause shearing of long cDNA fragments. In such a case, phenol-chloroform extraction or column purification can be considered.e. The reverse transcription products can be used directly for subsequent experiments such as PCR, or stored at -20℃ for future use. We recommend using 2µl reverse transcription products in a PCR reaction volume of 50µl.For other uses, please refer to the relevant literature of M-MuLV reverse transcriptase.FAQ:1. The reverse transcription product of total RNA is invisible after electrophoresis.It is a normal phenomenon, because the amount of RNA template is low, and the amount of reverse transcription products in different size is even lower.2. No specific product can be amplified from the reverse transcription product.a. To exclude the problem of PCR reaction system or reverse transcription product, use gene-specific primers to amplify internal reference genes, such as actin and GAPDH. Reference genes can be amplified but not the target gene, indicating primers of target gene are not well designed or the expression of the target gene is too low to be detected. b. Inappropriate primer is used for reverse transcription. Random hexamer instead of Oligo(dT)18 should be used for the reverse transcription of bacterial total RNA which does not have poly(A) tails. Gene-specific primers used for reverse transcription must be well designed... Read More | Inquire | Product contentF665766Component5 mLStorageF665766A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665766BddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Product contentF665766Component5 mLStorageF665766A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665766BddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemFinal concentration2×Fast Probe Mixture25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes in order to make the starting template fully unchained.(2) It is recommended to use two-step PCR reaction program, if you can not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out a three-step PCR amplification, annealing temperature, please use the range of 56 ℃ - 64 ℃ for as a reference for the setting... Read More | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | Purity>95% SDS-PAGE.FunctionProbable cell adhesion protein |