| Description | BGLAP Human Pre-designed siRNA Set A contains three designed siRNAs for BGLAP gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components BGLAP siRNA-1: 5 nmol (HPLC) BGLAP siRNA-2: 5 nmol (HPLC) BGLAP siRNA-3: 5 nmol (HPLC) siRNA Negative Control:BGLAP Human Pre-designed siRNA Set A contains three designed siRNAs for BGLAP gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components BGLAP siRNA-1: 5 nmol (HPLC) BGLAP siRNA-2: 5 nmol (HPLC) BGLAP siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Inquire | Product contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a preProduct contentF665774Component5 mLStorageF665774A2×Fast Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.F665774B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.F665774CddH2O5×1 mL-20℃. Avoid freeze/thaw cycle.Product IntroductionFast Probe Mixture is a pre-mixed system for real-time fluorescence PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, including Fast Taq DNA Polymerase, PCR Buffer, dNTPs, Mg2+ and so on, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequence and cDNA target sequence after RNA reverse transcription. The Fast Taq DNA Polymerase contained in this product can effectively reduce the non-specific amplification generated by the non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme only needs to be incubated at 95 ℃ for 30 s. The whole PCR reaction process can save about 40 minutes compared with the ordinary reaction, which greatly shortens the reaction time of PCR. The combination of unique PCR buffer system and fast hot start enzyme effectively inhibits the generation of non-specific products and significantly improves the PCR amplification efficiency with stronger fluorescence signal, higher sensitivity and wider linear range. The product has a wide range of applications and can be used for both normal and rapid quantitative PCR programs.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (F665766):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments that require Low ROX calibration (F665768):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments that require High ROX calibration (F665774):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attention1. Before use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.2. Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemreagents50µl reaction systemfinal concentration2×Fast Probe Mixture25 µl1×Forward Primer, 10µM1µl0.2µM¹⁾Reverse Primer, 10µM1µl0.2µM¹⁾Probe, 10 µM1µl0.2µM²⁾Template DNA2µl³⁾ 50x Low ROX or High ROX(optional)⁴⁾1µl1×ddH₂Oup to 50µlNote: 1) Usually the primer concentration of 0.2µM can get better results, and 0.1-1.0µM can be used as a reference for setting the range. 2) The final concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the instruction manual of the instrument or the specific requirements of the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2. PCR reaction program:A two-step PCR reaction program is recommended, and this program is set up using the ABI 7500 Fluorescent Quantitative PCR Instrument as a reference.Note: 1) The enzyme used in this product must be pre-denatured at 95°C for 30s to achieve enzyme activation. Under this condition, most of the templates can be well unchained. For templates with high GC content and complex secondary structure, the pre-denaturation time can be extended to 1-4 minutes to allow the starting template to fully unchain.(2) It is recommended to use two-step PCR reaction program, if you do not get good experimental results due to the use of primers with lower Tm values, etc., you can try to carry out three-step PCR amplification, and the annealing temperature, please use the range of 56 ℃ - 64 ℃ as a setting reference... Read More | H-7 dihydrochloride blocks human immunodeficiency virus (HIV-1) replication in MOLT-4 (clone No. 8) cell line. It increases the secretion of interleukin 1β (IL-1β).Application:H-7 dihydrochloride has been used to study H-7-induced inhibition of contractility in rat embryo H-7 dihydrochloride blocks human immunodeficiency virus (HIV-1) replication in MOLT-4 (clone No. 8) cell line. It increases the secretion of interleukin 1β (IL-1β).Application:H-7 dihydrochloride has been used to study H-7-induced inhibition of contractility in rat embryo fibroblasts (REF52) cells and acts as a kinase inhibitor... Read More | BackgroundStreptavidin is a tetrameric bacterial protein isolated from Streptomyces avidinii providing 4 high-affinity biotin binding sites. Streptavidin homo-tetramers have an extraordinarily high affinity for biotin. With a dissociation constant on the order of ≈10⁻¹⁴ mol/L,BackgroundStreptavidin is a tetrameric bacterial protein isolated from Streptomyces avidinii providing 4 high-affinity biotin binding sites. Streptavidin homo-tetramers have an extraordinarily high affinity for biotin. With a dissociation constant on the order of ≈10⁻¹⁴ mol/L, the binding of biotin to streptavidin is one of the strongest non-covalent interactions known in nature. Unlike egg-white avidin, which has a net positive charge at neutral pH and contains about 7% carbohydrate, streptavidin has almost no net charge at neutral pH, does not contain carbohydrate, and exhibits lower non-specific background. Streptavidin conjugates are widely used together with a conjugate of biotin for specific detection of a variety of proteins, protein motifs, nucleic acids and other molecules. This FITC-streptavidin conjugate was prepared by highly purified Streptavidin and free FITC was removed. Streptavidin (FITC) is a useful second-step reagent for the indirect immunofluorescent staining of cells in combination with biotinylated primary antibodies for flow cytometric analysis. Excitation at 488nm light leads to a fluorescence emission maximum of 520 nm.Recommended Usage:Every lot of Streptavidin-FITC is tested by flow cytometry using biotinylated primary antibodies. From this testing it is recommended that between 0.02 and 0.25 µg of streptavidin be used per 106 cells in a 100 µl staining volume... Read More |