| Description | GGT5 Human Pre-designed siRNA Set A contains three designed siRNAs for GGT5 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components GGT5 siRNA-1: 5 nmol (HPLC) GGT5 siRNA-2: 5 nmol (HPLC) GGT5 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 GGT5 Human Pre-designed siRNA Set A contains three designed siRNAs for GGT5 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components GGT5 siRNA-1: 5 nmol (HPLC) GGT5 siRNA-2: 5 nmol (HPLC) GGT5 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Amyloid β-Protein Fragment 25-35 (Aβ25-35) is derived from the amyloid-β protein.amyloid-β protein, which is mapped to human chromosome 21q21.Aβ25-35 lacks the N-terminal domain and the metal binding site and is majorly generated by proteolytic cleavage of Aβ(1−40Amyloid β-Protein Fragment 25-35 (Aβ25-35) is derived from the amyloid-β protein.amyloid-β protein, which is mapped to human chromosome 21q21.Aβ25-35 lacks the N-terminal domain and the metal binding site and is majorly generated by proteolytic cleavage of Aβ(1−40) peptides. It has a β-sheet and β-turn structure. Amino Acid Sequence Gly-Ser-Asn-Lys-Gly-Ala-Ile-Ile-Gly-Leu-MetFunctional domain of Aβ required for both neurotrophic and neurotoxic effects... Read More | 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to light yellow liquidOdour: odourlessIncubation temperature: 20-37 °CLight sensitiveHeat sensitive 2、Requirements for storage rooms and vessels1.Keep container tightly closed.2.Keep cool. protected from light3. Do not store together with: Oxidizing agent. 4. Contaminated or leaked out substrate solution from damaged bottles should not be used anymore and has to be destroyed.5. Use isolated containers with some cool bags for transport.6. Spontaneous decay will increase the background. If stored at room temperature, the velocity of the decay will increase. Thus, both storage and transport at room temperature should be avoided. Nevertheless, the activity of the solution is not affected by storage at room temperature. The solution still works beyond the expiry date, but some applications, especially those including visual evaluation, may be hampered by increased background. 3、Effective Components and Principle of FunctionIn different buffer solutions (pH = 9.5), with supplementation if required, the effective componentpara nitrophenyl phosphate (pNPP) is dissolved. Alkaline Phosphatase transfers the phosphate residue to an acceptor. Under alkaline conditions a yellow colour occurs, resulting from the formed nitrophenol. 4、Biosafety informationThis mixture is not classified as hazardous in accordance with Regulation (EC) No 1272/2008; 5、Advantage1. Signal yield comparable to competitor ready-to-use solutions2. Broad measurement range3. Very low background signals4. Very low blank drift during long-term storage (<0.15 AU within 24 months)5. High colour stability after reaction stop with this product and other commonly used stopping solutions 6、Instruction for usageFor bottling consider the following instructions:• Work in a dust free and darkened room.• Keep the solution as cool as possible.• Avoid contact of the solutions with any metal parts• Clean all instruments and vessels very extensively.• Wear powder-free gloves during bottling.• Close the bottles immediately to minimize the influence of light and dust.• Use clean bottles that are impermeable to light made from HDPE or PP. 7、 General Instructions for the Use in Blotting Systems Only qualified laboratory staff, who are familiar with the basics of immunological methods, are allowed to use these solutions.The substrate solutions can be used in qualitative and quantitative ELISA procedures.When using 96-well microtiter plates, adding 100 µL of substrate per well after incubation and washing is recommended. After substrate incubation the reaction can be stopped and the photometric measurement can be carried out. Using higher incubation temperatures (37° C) may shorten the incubation time. The reaction can be stopped by using the special developed solution stop. The use of other commercially available stop solutions cannot safely exclude a further increase of the signal. Addition of a stopping solution does not change the general shape of the spectrum. The unstopped and the stopped solution should be measured at 405 nm and the background correction: should be measured at 620 nm... Read More | GoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenientGoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenient. Mainly used for detecting genomic DNA target sequences and RNA reverse transcription cDNA target sequences, such as gene expression analysis, copy number analysis, SNP genotype analysis, etc., suitable for fluorescence quantification using different types of probe methods. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, novel and highly efficient hot start enzyme. It has no polymerase activity at room temperature, effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. The enzyme activation requires incubation at 95 ℃ for 10 minutes. The unique combination of PCR buffer system and hot start enzyme significantly improves the amplification efficiency of PCR, with stronger fluorescence signal and higher sensitivity, which can detect single copy templates. By using this product, a wider linear range can be obtained, resulting in more accurate quantification of the target gene. Suitable for all fluorescence quantitative PCR instruments that do not require ROX as a calibration dye.ROX dye is used to correct the fluorescence signal error between wells in quantitative PCR instruments, and is generally used in Real Time PCR amplification instruments from companies such as ABI and Stratagene. The excitation optical systems of different instruments vary, so the concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (CW0932): Roche LightCycle 480, Roche LightCyler 96, Bio rad iCyler iQ, iQ5, CFX96, etc.Instrument requiring Low ROX calibration (CW2625): ABI Prism7500/7500 Fast, QuantStudio ® 3 System, QuantStudio ® 5 System, QuantStudio ® 6 Flex System, QuantStudio ® 7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, etc.Instruments that require High ROX calibration (CW2626): ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.G665832Component5 mLStorageG665832A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665832BddH2O5×1 mL -20℃. Avoid freeze/thaw cycle. Notes:1. Before use, please gently mix upside down to avoid foaming, and use after briefly centrifugation.2. Avoid repeated freezing and thawing of this product, as repeated freezing and thawing may cause a decrease in product performance. This product can be stored for a long time at -20 ℃, away from light. If frequent use is required in the short term, it can be stored at 2-8 ℃.Usage:The following are examples of conventional PCR reaction systems and reaction conditions. In practical operation, corresponding improvements and optimizations should be made based on different templates, primer structures, and target fragment sizes.1. PCR reaction system Reagent 50 µl Reaction system Final concentration 2×GoldStar Probe Mixture 25 µl 1 × Forward Primer,10 µM 1 µl 0.2 µM¹⁾ Reverse Primer,10 µM 1 µl 0.2 µM¹⁾ Probe,10 µM 1 µl 0.2 µM²⁾ Template DNA 2 µl³⁾ / 50×Low ROX or High ROX(optional)⁴⁾ 1 µl 1 × ddH2O up to 50 µl / Attention:1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range.2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of DNA template is usually based on 10-100 ng genomic DNA or 1-10 ng cDNA as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the template to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.2. PCR reaction programAttention! The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes!Two step PCR Step Temperature Time / Pre denaturation 95℃ 10 min¹⁾ / Denaturation 95℃ 15 s 35-40 cycles Annealing/Extension ²⁾ 60℃ 1 min 35-40 cycles Attention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More |