| Description | CAMK4 Human Pre-designed siRNA Set A contains three designed siRNAs for CAMK4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components CAMK4 siRNA-1: 5 nmol (HPLC) CAMK4 siRNA-2: 5 nmol (HPLC) CAMK4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control:CAMK4 Human Pre-designed siRNA Set A contains three designed siRNAs for CAMK4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components CAMK4 siRNA-1: 5 nmol (HPLC) CAMK4 siRNA-2: 5 nmol (HPLC) CAMK4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Inquire | This product is a mixture of fast reverse transcription reagents. The 5 x EasyQuick RT MasterMix contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including EasyQuick RT Reversase, RNase Inhibitor, Random 6 mers, Oligo dT Primer, dNTP, EQ-RT BufferThis product is a mixture of fast reverse transcription reagents. The 5 x EasyQuick RT MasterMix contains all the reagents required for reverse transcription from RNA templates to cDNA first strand, including EasyQuick RT Reversase, RNase Inhibitor, Random 6 mers, Oligo dT Primer, dNTP, EQ-RT Buffer, etc. The reverse transcription efficiency of this product is high, and it can perform a good reverse transcription reaction on a small amount of RNA templates. The fluorescence quantitative template cDNA first strand synthesis can be completed in 15 minutes. This reagent kit is very convenient and fast to operate, and only RNA templates and water need to be added for reverse transcription reaction, making it particularly suitable for high-throughput detection.E665905Component200 TStorageE665905A5×EasyQuick RT MasterMix 400 µL-20℃. Avoid freeze/thaw cycle.E665905BRNase-Free Water 2×1 mL-20℃. Avoid freeze/thaw cycle. Product features1. Convenience: The ready to use reverse transcription Mix only requires the addition of RNA templates and water to initiate the reaction.2. Fast: Complete cDNA first strand synthesis in 15 minutes.3. High reverse transcription efficiency: The reverse transcription efficiency is above 90%.4. High sensitivity: PG level templates can also obtain high-quality cDNA.5. Read through complex templates: templates with high GC content and complex secondary structures.Matters needing attention1. During the operation, RNase contamination should be avoided to prevent RNA degradation or cross contamination during experiments. It is recommended that operators wear masks and disposable gloves, frequently change gloves, and use specialized instruments and consumables.2. The reverse transcription system is prepared on ice for operation to prevent RNA degradation. The MasterMix of the reagent kit should be stored at -20 ℃ as soon as possible after use, and repeated freeze-thaw should be avoided as much as possible.3.10 µ The reaction system can be used up to 1 µ G Total RNA, if the amount of template RNA is greater than 1 µ g. Please expand the reaction system proportionally.4. For RNA templates with complex secondary structures, it is recommended to incubate the template RNA at 65 ℃ for 5 minutes on ice before proceeding with the next step, followed by brief centrifugation.Operation steps1. Thaw the template RNA on ice; After thawing the components of the reagent kit at room temperature, immediately place them on ice. Before use, vortex shake and mix each solution, and centrifuge briefly before use.2. Prepare the reaction system according to the following table (please prepare the reaction solution on ice), vortex shake and mix well, briefly centrifuge, and collect the solution on the tube wall to the bottom of the tube. Reagent 10 µl Reaction system Final concentration RNA Template X µl 1 pg~0.5 µg ¹⁾ 5×EasyQuick RT MasterMix ²⁾ 2 µl 1× RNase-Free Water up to 10 µl /Attention:1) If the total RNA content is greater than 1 µ g, please expand the reaction system proportionally.2) 5 x EasyQuick RT MasterMix contains Oligo (dT), Random Prime, RNase Inhibitor, dNTP Mixture, EQ-RT Buffer, etc. 3. Incubate at 37 ℃ for 15 minutes. 4. Incubate at 85 ℃ for 5 seconds to inactivate reverse transcriptase.5. After a brief centrifugation, place it on ice for subsequent experiments. If it needs to be stored for a long time, please place it at -20 ℃... Read More | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | Inquire |