| Description | Gnrhr Rat Pre-designed siRNA Set A contains three designed siRNAs for Gnrhr gene (Rat), as well as a negative control, a positive control, and a FAM-labeled negative control. Components Gnrhr siRNA-1: 5 nmol (HPLC) Gnrhr siRNA-2: 5 nmol (HPLC) Gnrhr siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 Gnrhr Rat Pre-designed siRNA Set A contains three designed siRNAs for Gnrhr gene (Rat), as well as a negative control, a positive control, and a FAM-labeled negative control. Components Gnrhr siRNA-1: 5 nmol (HPLC) Gnrhr siRNA-2: 5 nmol (HPLC) Gnrhr siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new high efficient fast DNA Polymerase, Mg2+, dNTPs, and PCR stabilizers and enhancers at 2× concentration. It is a new rapid DNA polymerase developed by CombiSigma with high amplification speed and stability. The extension speed is up to 5 s/kb, and the PCR can be completed in as little as 15 minutes, while longer fragments (>3 kb) or complex templates can be extended at a speed of 10-30 s/kb or a higher number of cycles. The unique MasterMix formula makes the whole reaction system very stable, while complex templates can be amplified effectively, and more than 98% of PCR amplification can be successful in one run. Simply add the DNA template and primers and top up with water to minimize human error, contamination and time.The dye (blue) has been added to the product and it is ready for electrophoretic detection at the end of the reaction. The PCR product is amplified with an 'A' base at the 3′ end and can therefore be used directly for T/A cloning and is suitable for use in the CombiVerge Seamless Cloning Kit, T4 Ligation Kit and sensory products.This product is mainly suitable for ultra-fast PCR, complex templates, complex secondary structures, gene cloning and large-scale genetic testing that requires high fidelity. quality control No exogenous nuclease activity was detected; no host residual DNA was detected by PCR; single-copy genes in various genomes could be amplified efficiently. UsageThe following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template, which should be improved and optimized according to the template, primer structure and size of the target fragment in actual operation.PCR reaction system Note: Please use the final concentration of 0.1-1.0 µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the primer concentration can be increased; if a non-specific reaction occurs, the primer concentration can be decreased to optimize the reaction system.PCR reaction conditions Note: 1) Note: For simple templates, the pre-denaturation time can be controlled at 30 s-1 min, for complex templates such as bacterial fluids, the pre-denaturation time can be increased to 2 min.Optimization of parameter settings 1. Template DNA amount setting:Excessive amounts of template may result in non-specific amplification or smear. The recommended amount of template DNA in a 50 µl PCR reaction system is as follows:-Human genomic DNA 5 ng-500 ng-Escherichia coli genomic DNA 50 pg-100 ng-plasmid DNA 10 pg-1 ng 1. 30-35 number of cycles2. Primer concentration setting: The primer concentration can be set between 0.1 µM and 1.0 µM. A low primer concentration may result in low amplification products. Too high a primer concentration will inhibit specific amplification and may result in non-specific amplification.3. Annealing temperature setting: In general, the annealing temperature is 5℃ lower than the melting temperature of amplification primer Tm, so the annealing temperature can be lowered appropriately when the desired amplification efficiency cannot be obtained; the annealing temperature can be raised appropriately when non-specific reaction occurs. For complex templates, it is necessary to adjust the annealing temperature to achieve efficient amplification.4. Extension time setting: The extension time should be set according to the size of the amplified fragments. The following extension times are recommended: simple templates such as plasmids: 5-15 s/kb; regular genomes, cDNA templates: 10-15 s/kb; complex templates, crude templates: 20-30 s/kb; (the extension time should not be too short and should be at least 5 s/kb, but should not exceed 30 s/kb).5. Number of cycles: The number of cycles can be set according to the downstream application of the amplified product. If the number of cycles is too low, the amount of amplification will be insufficient; if the number of cycles is too high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield... Read More | Inquire | GoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenientGoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenient. Mainly used for detecting genomic DNA target sequences and RNA reverse transcription cDNA target sequences, such as gene expression analysis, copy number analysis, SNP genotype analysis, etc., suitable for fluorescence quantification using different types of probe methods. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, novel and highly efficient hot start enzyme. It has no polymerase activity at room temperature, effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. The enzyme activation requires incubation at 95 ℃ for 10 minutes. The unique combination of PCR buffer system and hot start enzyme significantly improves the amplification efficiency of PCR, with stronger fluorescence signal and higher sensitivity, which can detect single copy templates. By using this product, a wider linear range can be obtained, resulting in more accurate quantification of the target gene. Suitable for all fluorescence quantitative PCR instruments that do not require ROX as a calibration dye.ROX dye is used to correct the fluorescence signal error between wells in quantitative PCR instruments, and is generally used in Real Time PCR amplification instruments from companies such as ABI and Stratagene. The excitation optical systems of different instruments vary, so the concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (CW0932): Roche LightCycle 480, Roche LightCyler 96, Bio rad iCyler iQ, iQ5, CFX96, etc.Instrument requiring Low ROX calibration (CW2625): ABI Prism7500/7500 Fast, QuantStudio ® 3 System, QuantStudio ® 5 System, QuantStudio ® 6 Flex System, QuantStudio ® 7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, etc.Instruments that require High ROX calibration (CW2626): ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.G665832Component5 mLStorageG665832A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665832BddH2O5×1 mL -20℃. Avoid freeze/thaw cycle. Notes:1. Before use, please gently mix upside down to avoid foaming, and use after briefly centrifugation.2. Avoid repeated freezing and thawing of this product, as repeated freezing and thawing may cause a decrease in product performance. This product can be stored for a long time at -20 ℃, away from light. If frequent use is required in the short term, it can be stored at 2-8 ℃.Usage:The following are examples of conventional PCR reaction systems and reaction conditions. In practical operation, corresponding improvements and optimizations should be made based on different templates, primer structures, and target fragment sizes.1. PCR reaction system Reagent 50 µl Reaction system Final concentration 2×GoldStar Probe Mixture 25 µl 1 × Forward Primer,10 µM 1 µl 0.2 µM¹⁾ Reverse Primer,10 µM 1 µl 0.2 µM¹⁾ Probe,10 µM 1 µl 0.2 µM²⁾ Template DNA 2 µl³⁾ / 50×Low ROX or High ROX(optional)⁴⁾ 1 µl 1 × ddH2O up to 50 µl / Attention:1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range.2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of DNA template is usually based on 10-100 ng genomic DNA or 1-10 ng cDNA as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the template to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.2. PCR reaction programAttention! The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes!Two step PCR Step Temperature Time / Pre denaturation 95℃ 10 min¹⁾ / Denaturation 95℃ 15 s 35-40 cycles Annealing/Extension ²⁾ 60℃ 1 min 35-40 cycles Attention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Biochemical Test:Electrophoresis (purity > 80%) |