| Description | HDDC2 Human Pre-designed siRNA Set A contains three designed siRNAs for HDDC2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components HDDC2 siRNA-1: 5 nmol (HPLC) HDDC2 siRNA-2: 5 nmol (HPLC) HDDC2 siRNA-3: 5 nmol (HPLC) siRNA Negative Control:HDDC2 Human Pre-designed siRNA Set A contains three designed siRNAs for HDDC2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components HDDC2 siRNA-1: 5 nmol (HPLC) HDDC2 siRNA-2: 5 nmol (HPLC) HDDC2 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Protein Purity≥85% by SDS PAGEExtinction CoeffA280 nm = 0.974 at 1.0 mg/ml for pure C3bMolecular Weight185,000 Da (2 chains)General DescriptionCynomolgus monkey C3 (cyno C3) is purified from pooled normal cynomolgus monkey serum. C3 is central to the activation of all three pathways of Protein Purity≥85% by SDS PAGEExtinction CoeffA280 nm = 0.974 at 1.0 mg/ml for pure C3bMolecular Weight185,000 Da (2 chains)General DescriptionCynomolgus monkey C3 (cyno C3) is purified from pooled normal cynomolgus monkey serum. C3 is central to the activation of all three pathways of complement activation (Law, S.K.A. and Reid, K.B.M. (1995)). Initiation of each pathway generates proteolytic enzyme complexes (C3 convertases) which are bound to the target surface. These enzymes cleave a peptide bond in C3 releasing the anaphylatoxin C3a and activating C3b. For a brief time (~60 µs) this nascent C3b is capable of reacting with and covalently coupling to hydroxyl groups on the target surface. Carbohydrates are the favored target, but protein hydroxyls and amino groups also react. This process of tagging the target surface with C3b is called opsonization. The reactive site in nascent C3b is a thioester (Tack B.J., et al. (1980); Pangburn M.K. and MüllerEberhard H.J. (1980)) and C3b is linked to the target through a covalent ester bond (an amide bond is formed if C3b is attached to amino groups). Most of the C3 activated during complement activation never attaches to the surface because its thioester reacts with water forming fluid phase C3b which is rapidly inactivated by factors H and I forming iC3b. Surface-bound C3b is necessary in all three pathways for efficient activation of C5 and formation of C5b-9 complexes that lyse the target cell membrane. Surface-bound C3b and its breakdown products iC3b and C3d are recognized by numerous receptors on lymphoid and phagocytic cells which use the C3b ligand to stimulate antigen presentation to cells of the adaptive immune system. The end result is an expansion of target-specific B-cell and T-cell populations.Physical Characteristics & StructureCynomolgus monkey C3 is an uncharacterized protein. The calculated molecular weight based on its amino acid sequence is 184,926 daltons similar to that of human C3 (185,000 daltons). Like human C3, cyno C3 is composed of two disulfide-linked chains. Analysis of purified cyno C3 by SDS/polyacrylamide gel electrophoresis under non-reduced conditions shows the mobility of cyno C3 to be similar to that of human C3. Under reduced conditions, the migration of the alpha chain of cyno C3 is comparable to that of human C3 alpha chain (110,000 daltons) while the beta chain migrates slightly ahead of the human C3 beta chain (75,000daltons).The extinction coefficient of cyno C3 is calculated from its amino acid sequence using ProtParam and assumes all pairs of Cys residues form cystines (i.e. a pair of cystine molecules are joined by a disulfide bond). The theoretical pI value for cyno monkey C3 is 6.03. Employing immunoturbidimetric method the serum concentration of cyno C3 has been reported to be 1.27 mg/ml in males and 1.1 mg/ml in female monkeys (Park H-K et al., (2016)). FunctionThe biological functions of C3 are described above in the General Description and Physical Characteristics sections.GeneticsCynomolgus monkey C3 chromosome location 19. The NCBI Gene ID number for Cynomolgus monkey C3 is 102131458 and UniProt accession number is A0A2K5VPN1.Precautions/Toxicity/HazardsThis protein is purified from animal serum and therefore precautions appropriate for handling any animal blood-derived product must be used.ReferencesLaw, S.K.A. and Reid, K.B.M. (1995) Complement 2nd Edition (ISBN 0199633568) Oxford University Press, Oxford.Tack BF, Harrison RA, Janatova J, Thomas ML, Prahl JW. (1980) Evidence for presence of an internal thiolester bond in third component of human complement. Proc Natl Acad Sci U S A. 77:5764-8.Pangburn M.K. and Müller-Eberhard H.J. (1980) Relation of putative thioester bond in C3 to activation of the alternative pathway and the binding of C3b to biological targets of complement. J Exp Med. 152:1102-14.Park H-K, Cho J-W, Lee B-S, Park H, Han J-S, Yang M-J, Im W-J, Park D-Y, Kim W-J, Han SC, Kim Y-B. (2016) Reference values of clinical pathology parameters in cynomolgus monkeys (Macaca fascicularis) used in preclinical studies. Lab Anim Res. 32(2):79-86... Read More | GoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenientGoldStar Probe Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using probe methods (TaqMan, Molecular Beacon, etc.), with a concentration of 2 x, containing GoldStar Taq DNA Polymerase, PCR Buffer, dNTPs, and Mg2+. The operation is simple and convenient. Mainly used for detecting genomic DNA target sequences and RNA reverse transcription cDNA target sequences, such as gene expression analysis, copy number analysis, SNP genotype analysis, etc., suitable for fluorescence quantification using different types of probe methods. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, novel and highly efficient hot start enzyme. It has no polymerase activity at room temperature, effectively avoiding non-specific amplification caused by non-specific binding of primers and templates or primer dimerization at room temperature. The enzyme activation requires incubation at 95 ℃ for 10 minutes. The unique combination of PCR buffer system and hot start enzyme significantly improves the amplification efficiency of PCR, with stronger fluorescence signal and higher sensitivity, which can detect single copy templates. By using this product, a wider linear range can be obtained, resulting in more accurate quantification of the target gene. Suitable for all fluorescence quantitative PCR instruments that do not require ROX as a calibration dye.ROX dye is used to correct the fluorescence signal error between wells in quantitative PCR instruments, and is generally used in Real Time PCR amplification instruments from companies such as ABI and Stratagene. The excitation optical systems of different instruments vary, so the concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (CW0932): Roche LightCycle 480, Roche LightCyler 96, Bio rad iCyler iQ, iQ5, CFX96, etc.Instrument requiring Low ROX calibration (CW2625): ABI Prism7500/7500 Fast, QuantStudio ® 3 System, QuantStudio ® 5 System, QuantStudio ® 6 Flex System, QuantStudio ® 7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, etc.Instruments that require High ROX calibration (CW2626): ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.G665832Component5 mLStorageG665832A2×GoldStar Probe Mixture5×1 mL-20℃. Avoid freeze/thaw cycle.G665832BddH2O5×1 mL -20℃. Avoid freeze/thaw cycle. Notes:1. Before use, please gently mix upside down to avoid foaming, and use after briefly centrifugation.2. Avoid repeated freezing and thawing of this product, as repeated freezing and thawing may cause a decrease in product performance. This product can be stored for a long time at -20 ℃, away from light. If frequent use is required in the short term, it can be stored at 2-8 ℃.Usage:The following are examples of conventional PCR reaction systems and reaction conditions. In practical operation, corresponding improvements and optimizations should be made based on different templates, primer structures, and target fragment sizes.1. PCR reaction system Reagent 50 µl Reaction system Final concentration 2×GoldStar Probe Mixture 25 µl 1 × Forward Primer,10 µM 1 µl 0.2 µM¹⁾ Reverse Primer,10 µM 1 µl 0.2 µM¹⁾ Probe,10 µM 1 µl 0.2 µM²⁾ Template DNA 2 µl³⁾ / 50×Low ROX or High ROX(optional)⁴⁾ 1 µl 1 × ddH2O up to 50 µl / Attention:1) Typically, the primer concentration is 0.2 µ M can achieve good results, ranging from 0.1 to 1.0 µ M serves as a reference for setting the range.2) The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance. Please refer to the instrument manual or the specific usage requirements of each fluorescent probe for concentration adjustment during actual use.3) The amount of DNA template is usually based on 10-100 ng genomic DNA or 1-10 ng cDNA as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the template to determine the optimal template usage.4) The excitation optical systems of different instruments vary, and depending on the instrument used for fluorescence quantification, 50 x Low ROX or 50 x High ROX can be added.2. PCR reaction programAttention! The pre denaturation reaction of this product must be completed at 95 ℃ for 10 minutes!Two step PCR Step Temperature Time / Pre denaturation 95℃ 10 min¹⁾ / Denaturation 95℃ 15 s 35-40 cycles Annealing/Extension ²⁾ 60℃ 1 min 35-40 cycles Attention:1) The hot start enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 10 minutes.2) It is recommended to use a two-step PCR reaction program. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference... Read More | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More | Inquire |