| Description | Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution Annexins are a family of calcium-dependent phospholipid-binding proteins that preferentially bind phosphatidylserine (PS). Under normal physiologic conditions, PS is predominantly located in the inner leaflet of the plasma membrane. Upon initiation of apoptosis, PS loses its asymmetric distribution across the phospholipid bilayer and is translocated to the extracellular membrane leaflet marking cells as targets of phagocytosis. Once on the outer surface of the membrane, PS can be detected by fluorescently labeled Annexin V in a calcium-dependent manner.In early-stage apoptosis, the plasma membrane excludes viability dyes such as propidium iodide (PI), 7-AAD. These cells will stain with Annexin V but not a viability dye, thus distinguishing cells in early apoptosis. However, in late stage apoptosis, the cell membrane loses integrity thereby allowing Annexin V to also access PS in the interior of the cell. A viability dye can be used to resolve these late-stage apoptotic and necrotic cells (Annexin V, viability dye-positive) from the early-stage apoptotic cells (Annexin V positive, viability dye-negative).We offer recombinant Annexin V conjugated to a numerous fluorophores, as well as an Annexin V biotin conjugate which can be detected with fluorophore-labeled streptavidin. By binding to PS, fluorophores labeled Annexin V can be used to detect and quantify apoptotic cells via flow cytometry or fluorescence microscopy. Cat.No.Ex/Em (nm)Formatrp226056NABiotinrp225999401/422AF405rp226057490/525AF488rp226060650/668AF647rp226002681/704AF680rp226003752/776AF750rp226053498/517FITCrp226004410/455Pacific Bluerp226006647/665Cy5rp226054650/660APCrp226055565/575PErp226058565/670PE-Cy5rp226059565/774PE-Cy7Precautions1. Please try to avoid light when using to slow down the quenching of fluorescence.2. Propidium Iodide Solution is toxigenic and mutagenic; handle with care.3. Due to the calcium dependence of the Annexin V:PS interaction, it is critical to avoid buffers containing EDTA or other calcium chelators during Annexin V experiments.Instruction for use1. Dilute 10X Binding Buffer (A1372288) to 1X using distilled water (1 mL 10X Binding Buffer + 9 mL ddH2O).2. Wash cells twice with cold PBS and then resuspend the desired amounts of cells in Annexin V Binding Buffer at a concentration of 1.0-5.0 x 106 cells/mL.3. Add 5 µL of Annexin V-PE to 100 µL of the cell suspension. Stain with a viability dye, such as PI (P1373641; P1372285), 7-AAD (A1372406), or DAPI (D1372407) dyes, if desired.4. Gently vortex the cells and incubate for 10 min at RT (25°C) in the dark.5. Add 100 µL of 1X Binding Buffer to each assay. Analyze by flow cytometry within 1 hr... Read More | Bovine pancreatic deoxyribonuclease is an endonuclease which splits phosphodiester linkages, preferentially adjacent to a pyrimidine nucleotide yielding polynucleotides with free hydroxyl group at the 3' position and phosphate group at the 5' position. The average chain length of a limit digest is aBovine pancreatic deoxyribonuclease is an endonuclease which splits phosphodiester linkages, preferentially adjacent to a pyrimidine nucleotide yielding polynucleotides with free hydroxyl group at the 3' position and phosphate group at the 5' position. The average chain length of a limit digest is a tetranucleotide.Used for the removal of DNA from protein samples. Deoxyribonuclease I from bovine pancreas has been used in a study to compare several procedures for reducing RNase contamination in preparations of DNase. Deoxyribonuclease I from bovine pancreas has also been used in a study to investigate the effect of the composition of sodium dodecyl sulfate preparations on the renaturation of enzymes after polyacrylamide gel electrophoresis... Read More | EPOCROSTM is a reactive polymer with an oxazoline group on the side chain and is used as a cross-linking agent for water-based resins. Among the water-based polymers developed to address environmental issues and the increasing use of water-based products due to VOC regulations and desolventing, the EPOCROSTM is a reactive polymer with an oxazoline group on the side chain and is used as a cross-linking agent for water-based resins. Among the water-based polymers developed to address environmental issues and the increasing use of water-based products due to VOC regulations and desolventing, the EPOCROSTM WS series is a “water-soluble type” with the following structure.Features and PropertiesHigher reactivity than water-based epoxy, melamine, blocked isocyanateVOC free (EPOCROS™ WS-300 and EPOCROS™ WS-700)High crosslinking density with a small amount addedOne-pack type with long usage timeImproves water resistance, solvent resistance, heat resistance, and the strength of films, etc.Adhesion-imparting possible to PET, OPP, PVC, etc.Fast dryingLow toxicity (Ames Test: Negative, Primary Skin Irritation Test: No irritation)WS Series Product LineupApplicationsNonwoven fabric bindersPigment printingCoatings (metals, films, leather)Paint and coatings, Primers (plastics, building materials, vehicles)AdhesivesMethodASSAY for Product Code DILW:One unit equals a decrease in absorbance of 1.0 per minute at 25°C at pH 7.5 with 2,6-dichlorophenolindophenol as the chromogen.Reagents0.2 M Tris⋅HCl buffer, pH 7.50.006 M NADH. Prepare fresh daily.0.0012 M Dichlorophenolindophenol (DCPIP) Prepare fresh daily.EnzymePrepare a 10 mg/ml solution of enzyme in 0.2 M Tris⋅HCl, pH 7.5.Dilute further immediately before use to give ΔA/min of 0.15-0.20.ProcedureAdjust spectrophotometer to 600 nm and 25°C.Pipette into cuvettes as follows:Mix quickly and measure the decrease in absorbance at 600 nm for 2-3 minutes.Determine the ΔA/min. from the initial linear portion of the curve. (Use portion of curve from t=0 to t=1 minute; the rate is linear for 1/2 to 1 minute.)Calculation... Read More | ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology experiments, such as PCR, enzyme digestion, hybridization, microarray analysis, and other molecular biology experiments.The product was quantified using NanoDrop One at a concentration of 200 ng/µL.Preparation and precautions before useLong-term storage at -20˚C is recommended. Before use, the bottle should be removed from the refrigerator and equilibrated to room temperature and centrifuged before opening the cap for use. Samples should be restored to the sealed state as soon as possible after opening.How to use (take qPCR experiment as an example)1. Amplification template preparationThe samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0,1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. The samples were placed on ice at 4°C and set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard 1 (100ng/uL) with TE to make 5 different concentrations of standards according to the table below. 10ng/µL of DNA Standard 1 (Std. 1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When not used temporarily after preparation, it should be stored at 4℃ or on ice.styleCorresponding concentration (ng/µL)Minimum dilution volume (in µL)Std.11010 [100 ng/µL DNA Standard 1] + 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationThe cryopreserved reagents to be used were completely thawed and mixed by inversion several times before preparation, and then briefly centrifuged and prepared for use. 20 µL of the base reaction system was as follows.The base reaction system for 20 µL was as follows:reagents20µL reaction system2×qPCRMix10µLPrimerMixXµLProbeMixXµLTemplate4µLddH2OMake up to 20 µLNote: High Rox model: add 1 µL of 50×High Rox per 50 µL of reaction system; Low Rox model: add 1 µL of 50×High Rox per 500 µL of reaction system.Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the manual of the instrument or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration during actual use.Prepare a sufficient amount of reaction system mixture as required. After the reaction system has been prepared and mixed thoroughly, add 16 µL per well to the reaction wells. Then add the prepared standard and diluted sample into the corresponding reaction wells, the volume of addition is 4µL/well. TE was added to the blank control tube, and the same amount of TE was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe following is an example of our GoldStar Probe Mixture reaction conditions, which should be improved and optimized according to the PCR product template, primer structure and target fragment size.movetemptimingcirculatepremutability95°C10min1denaturation95°C10sec55Annealing/Extension60°C30sec5Data analysis1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should not be lower than 0.98, and the slope should be between -3.1 and -3.6 when the Ct value is the vertical coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment... Read More | Inquire |