| Description | H3-5 Human Pre-designed siRNA Set A contains three designed siRNAs for H3-5 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components H3-5 siRNA-1: 5 nmol (HPLC) H3-5 siRNA-2: 5 nmol (HPLC) H3-5 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 H3-5 Human Pre-designed siRNA Set A contains three designed siRNAs for H3-5 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components H3-5 siRNA-1: 5 nmol (HPLC) H3-5 siRNA-2: 5 nmol (HPLC) H3-5 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Inquire | Inquire | 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to 1、Product attributeShelf life: 24 monthsReaction time:long (up to 45 minutes) at 20-37°CLot-to-lot variation:<10%Boiling point : 100℃pH-Value (at 20 °C): 9.0-9.8 Density (20℃) : 1.0302 g/cm³Water solubility: easily solubleAppearance: colourless to light yellow liquidOdour: odourlessIncubation temperature: 20-37 °CLight sensitiveHeat sensitive 2、Requirements for storage rooms and vessels1.Keep container tightly closed.2.Keep cool. protected from light3. Do not store together with: Oxidizing agent. 4. Contaminated or leaked out substrate solution from damaged bottles should not be used anymore and has to be destroyed.5. Use isolated containers with some cool bags for transport.6. Spontaneous decay will increase the background. If stored at room temperature, the velocity of the decay will increase. Thus, both storage and transport at room temperature should be avoided. Nevertheless, the activity of the solution is not affected by storage at room temperature. The solution still works beyond the expiry date, but some applications, especially those including visual evaluation, may be hampered by increased background. 3、Effective Components and Principle of FunctionIn different buffer solutions (pH = 9.5), with supplementation if required, the effective componentpara nitrophenyl phosphate (pNPP) is dissolved. Alkaline Phosphatase transfers the phosphate residue to an acceptor. Under alkaline conditions a yellow colour occurs, resulting from the formed nitrophenol. 4、Biosafety informationThis mixture is not classified as hazardous in accordance with Regulation (EC) No 1272/2008; 5、Advantage1. Signal yield comparable to competitor ready-to-use solutions2. Broad measurement range3. Very low background signals4. Very low blank drift during long-term storage (<0.15 AU within 24 months)5. High colour stability after reaction stop with this product and other commonly used stopping solutions 6、Instruction for usageFor bottling consider the following instructions:• Work in a dust free and darkened room.• Keep the solution as cool as possible.• Avoid contact of the solutions with any metal parts• Clean all instruments and vessels very extensively.• Wear powder-free gloves during bottling.• Close the bottles immediately to minimize the influence of light and dust.• Use clean bottles that are impermeable to light made from HDPE or PP. 7、 General Instructions for the Use in Blotting Systems Only qualified laboratory staff, who are familiar with the basics of immunological methods, are allowed to use these solutions.The substrate solutions can be used in qualitative and quantitative ELISA procedures.When using 96-well microtiter plates, adding 100 µL of substrate per well after incubation and washing is recommended. After substrate incubation the reaction can be stopped and the photometric measurement can be carried out. Using higher incubation temperatures (37° C) may shorten the incubation time. The reaction can be stopped by using the special developed solution stop. The use of other commercially available stop solutions cannot safely exclude a further increase of the signal. Addition of a stopping solution does not change the general shape of the spectrum. The unstopped and the stopped solution should be measured at 405 nm and the background correction: should be measured at 620 nm... Read More | Product Characteristics UNI-StabilPLUS is a universal stabilizer for the dilution and stabilization of both Horseradish Peroxidase (HRP) and Alkaline Phosphatase (AP) labeled proteins and antibodies, in order to maintain the molecular conformation and prevent loss of activity over time. This enablesProduct Characteristics UNI-StabilPLUS is a universal stabilizer for the dilution and stabilization of both Horseradish Peroxidase (HRP) and Alkaline Phosphatase (AP) labeled proteins and antibodies, in order to maintain the molecular conformation and prevent loss of activity over time. This enables the making of pre-diluted, ready-to-use conjugates, minimizing assay errors in dilution. Superior stabilization of HRP and AP conjugated antibodies in low as well as high protein dilutions is seen, when using UNI-StabilPLUS. When tested with AP conjugated antibody stability is seen as follows: • at least 3 years at 2-8 °C • at least 2 years at room temperature • at least 4 weeks at 37 °C When tested with HRP conjugated antibody stability is seen as follows: • at least 2 years at 2-8 °C • at least 1 years at room temperature • at least 2 weeks at 37 °CUNI-StabilPLUS is recommended for the dilution of antibodies directed against rabbit immunoglobulins unlike HRP-StabilPLUS (cat. no. H494387) and Antibody Enhancer (cat. no. A494276).Composition & Properties UNI-StabilPLUS is a ready-to use buffer that appears as an opaque solution. The product is based on a mild acid Tris buffer containing proprietary stabilizing components. UNI-StabilPLUS contains neither BSA, nor other material from bovine serum, no azide, mercury or other toxic components.Working Procedure 1.Make a series of dilutions of the HRP- or AP conjugated protein in UNI-StabilPLUS in order to determine the optimal dilution. 2.Run the assay as usual or store the diluted conjugated protein preferably at 2-8 °C.Tips & Tricks • Avoid using phosphate buffers for AP-conjugated antibody assays. We recommend the use of Tris/HCl, Tween as the washing buffer, instead of a PBS buffer which will reduce signal significantly. • For extended stability of HRP conjugated antibodies, HRP-StabilPLUS (cat. no. H494387) is recommended. Handling & Storage • Store solution at 2-8 °C... Read More |