| Description | KLC4 Human Pre-designed siRNA Set A contains three designed siRNAs for KLC4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components KLC4 siRNA-1: 5 nmol (HPLC) KLC4 siRNA-2: 5 nmol (HPLC) KLC4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 KLC4 Human Pre-designed siRNA Set A contains three designed siRNAs for KLC4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components KLC4 siRNA-1: 5 nmol (HPLC) KLC4 siRNA-2: 5 nmol (HPLC) KLC4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new Product Content:F665667Component5 mL40 mLStorageF665667A2×Flash PCR MasterMix (Dye) 5×1 mL 40×1 mL-20℃. Avoid freeze/thaw cycle.F665667BddH2O 5×1 mL40×1 mL-20℃. Avoid freeze/thaw cycle. Products Introduction This product is a premixed system consisting of a new high efficient fast DNA Polymerase, Mg2+, dNTPs, and PCR stabilizers and enhancers at 2× concentration. It is a new rapid DNA polymerase developed by CombiSigma with high amplification speed and stability. The extension speed is up to 5 s/kb, and the PCR can be completed in as little as 15 minutes, while longer fragments (>3 kb) or complex templates can be extended at a speed of 10-30 s/kb or a higher number of cycles. The unique MasterMix formula makes the whole reaction system very stable, while complex templates can be amplified effectively, and more than 98% of PCR amplification can be successful in one run. Simply add the DNA template and primers and top up with water to minimize human error, contamination and time.The dye (blue) has been added to the product and it is ready for electrophoretic detection at the end of the reaction. The PCR product is amplified with an 'A' base at the 3′ end and can therefore be used directly for T/A cloning and is suitable for use in the CombiVerge Seamless Cloning Kit, T4 Ligation Kit and sensory products.This product is mainly suitable for ultra-fast PCR, complex templates, complex secondary structures, gene cloning and large-scale genetic testing that requires high fidelity. quality control No exogenous nuclease activity was detected; no host residual DNA was detected by PCR; single-copy genes in various genomes could be amplified efficiently. UsageThe following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template, which should be improved and optimized according to the template, primer structure and size of the target fragment in actual operation.PCR reaction system Note: Please use the final concentration of 0.1-1.0 µM as a reference for setting the range of primer concentration. If the amplification efficiency is not high, the primer concentration can be increased; if a non-specific reaction occurs, the primer concentration can be decreased to optimize the reaction system.PCR reaction conditions Note: 1) Note: For simple templates, the pre-denaturation time can be controlled at 30 s-1 min, for complex templates such as bacterial fluids, the pre-denaturation time can be increased to 2 min.Optimization of parameter settings 1. Template DNA amount setting:Excessive amounts of template may result in non-specific amplification or smear. The recommended amount of template DNA in a 50 µl PCR reaction system is as follows:-Human genomic DNA 5 ng-500 ng-Escherichia coli genomic DNA 50 pg-100 ng-plasmid DNA 10 pg-1 ng 1. 30-35 number of cycles2. Primer concentration setting: The primer concentration can be set between 0.1 µM and 1.0 µM. A low primer concentration may result in low amplification products. Too high a primer concentration will inhibit specific amplification and may result in non-specific amplification.3. Annealing temperature setting: In general, the annealing temperature is 5℃ lower than the melting temperature of amplification primer Tm, so the annealing temperature can be lowered appropriately when the desired amplification efficiency cannot be obtained; the annealing temperature can be raised appropriately when non-specific reaction occurs. For complex templates, it is necessary to adjust the annealing temperature to achieve efficient amplification.4. Extension time setting: The extension time should be set according to the size of the amplified fragments. The following extension times are recommended: simple templates such as plasmids: 5-15 s/kb; regular genomes, cDNA templates: 10-15 s/kb; complex templates, crude templates: 20-30 s/kb; (the extension time should not be too short and should be at least 5 s/kb, but should not exceed 30 s/kb).5. Number of cycles: The number of cycles can be set according to the downstream application of the amplified product. If the number of cycles is too low, the amount of amplification will be insufficient; if the number of cycles is too high, the chance of mismatch will increase and the non-specific background will be serious. Therefore, the number of cycles should be minimized under the premise of ensuring the product yield... Read More | Inquire | Extinction CoeffA280 nm = 1.0 at 1.0 mg/mlGeneral DescriptionProduct is whole polyclonal antiserum from goats immunized with highly purified mouse complement protein. This product is not a purified IgG fraction. Goats are maintained in FDA certified facilities.Physical Characteristics & Extinction CoeffA280 nm = 1.0 at 1.0 mg/mlGeneral DescriptionProduct is whole polyclonal antiserum from goats immunized with highly purified mouse complement protein. This product is not a purified IgG fraction. Goats are maintained in FDA certified facilities.Physical Characteristics & StructureAntibodies present in the antisera are primarily IgG.ApplicationsImmunodiffusion: Effective against NMS and plasma at 1/32 dilution Suggested starting dilutions:Western Blot: 1/500 to 1/1000. Most effective against non-reduced antigen.ELISA: 1/500 to 1/2000... Read More | ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology experiments, such as PCR, enzyme digestion, hybridization, microarray analysis, and other molecular biology experiments.The product was quantified using NanoDrop One at a concentration of 200 ng/µL.Preparation and precautions before useLong-term storage at -20˚C is recommended. Before use, the bottle should be removed from the refrigerator and equilibrated to room temperature and centrifuged before opening the cap for use. Samples should be restored to the sealed state as soon as possible after opening.How to use (take qPCR experiment as an example)1. Amplification template preparationThe samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0,1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. The samples were placed on ice at 4°C and set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard 1 (100ng/uL) with TE to make 5 different concentrations of standards according to the table below. 10ng/µL of DNA Standard 1 (Std. 1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When not used temporarily after preparation, it should be stored at 4℃ or on ice.styleCorresponding concentration (ng/µL)Minimum dilution volume (in µL)Std.11010 [100 ng/µL DNA Standard 1] + 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationThe cryopreserved reagents to be used were completely thawed and mixed by inversion several times before preparation, and then briefly centrifuged and prepared for use. 20 µL of the base reaction system was as follows.The base reaction system for 20 µL was as follows:reagents20µL reaction system2×qPCRMix10µLPrimerMixXµLProbeMixXµLTemplate4µLddH2OMake up to 20 µLNote: High Rox model: add 1 µL of 50×High Rox per 50 µL of reaction system; Low Rox model: add 1 µL of 50×High Rox per 500 µL of reaction system.Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the manual of the instrument or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration during actual use.Prepare a sufficient amount of reaction system mixture as required. After the reaction system has been prepared and mixed thoroughly, add 16 µL per well to the reaction wells. Then add the prepared standard and diluted sample into the corresponding reaction wells, the volume of addition is 4µL/well. TE was added to the blank control tube, and the same amount of TE was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe following is an example of our GoldStar Probe Mixture reaction conditions, which should be improved and optimized according to the PCR product template, primer structure and target fragment size.movetemptimingcirculatepremutability95°C10min1denaturation95°C10sec55Annealing/Extension60°C30sec5Data analysis1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should not be lower than 0.98, and the slope should be between -3.1 and -3.6 when the Ct value is the vertical coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment... Read More |