| Description | ATP13A2 Human Pre-designed siRNA Set A contains three designed siRNAs for ATP13A2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ATP13A2 siRNA-1: 5 nmol (HPLC) ATP13A2 siRNA-2: 5 nmol (HPLC) ATP13A2 siRNA-3: 5 nmol (HPLC) siRNA ATP13A2 Human Pre-designed siRNA Set A contains three designed siRNAs for ATP13A2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ATP13A2 siRNA-1: 5 nmol (HPLC) ATP13A2 siRNA-2: 5 nmol (HPLC) ATP13A2 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Inquire | Protein Purity>95% by SDS-PAGEExtinction Coeff.A276 nm = 0.456 at 1.0 mg/mLMolecular Weight8,759 Da (single chain)General DescriptionNatural human C4a is prepared by cleavage of human C4 protein by human C1s. It is produced during activation of both the classical and lectin pathways of complementProtein Purity>95% by SDS-PAGEExtinction Coeff.A276 nm = 0.456 at 1.0 mg/mLMolecular Weight8,759 Da (single chain)General DescriptionNatural human C4a is prepared by cleavage of human C4 protein by human C1s. It is produced during activation of both the classical and lectin pathways of complement. C4a is a member of the anaphylatoxin family of three proteins (C3a, C4a and C5a) produced by the activation of complement (Hugli, T.E. et al. (1981)). It is an unglycosylated polypeptidecontaining 77 amino acids with a molecular mass of 8,759 daltons. Many of the biological functions of C4a are similar to those of C3a, but the specific activities are far below those of C3a. C4a activity is so low, in fact, that it was initially thought to be inactive. These measured activities include inducing muscle contraction in the guinea pig ileum test (spasmogenic activity), desensitization of muscle to C3a stimulation suggesting that the same receptor for both C3a and C4a is involved (tachyphylactic activity) and inducing vascular permeability in human skin (Gorski J.P. et al. (1979)). C4a does not show tachyphylactic activity against C5a or chemotactic activity. Removal of the C-terminal arginine by serum carboxypeptidase N destroys all these activities (Meuller-Ortiz, S.L., et al. (2009)). C4a appears to act through the C3a receptor (C3aR) which is a G-protein coupled receptor found widely distributed on peripheral tissues, lymphoid cells (neutrohphils, monocyes, and eosinophils) and in the central nervous system (astrocytes, neurons and glial cells) (Law, S.K.A. and Reid, K.B.M. (1995)). Physical Characteristics & StructureMolecular weight: 8,759 calculated molecular mass. Observed mass (MALDI-TOF) is 8,762 + 9 mass units. pI = 9.0 to 9.5 (Gorski, J.P. et al. (1981))Amino acid sequence (77 amino acids): NVNFQKAINE KLGQYASPTA KRCCQDGVTR LPMMRSCEQR AARVQQPDCR EPFLSCCQFA ESLRKKSRDK GQAGLQRC4a is thought to be structurally very similar to C3a and C5a to which it is homologous. Thus its 3D structure is probably similar to the X-ray-derived crystal structureof C3a (Huber, R. et al. (1980)) and the NMR derived structure of C3a: Nettesheim, D.G. et al. (1988); Murray, I. et al. (1999).FunctionSee General Description above. C4a exhibits much weaker biological activities than C3a and C5a. Its activity in inducing erythema and edema in human skin is 25,000-fold weaker than that of C5a and 100-fold weaker than C3a per nanomole. The spasmogenic activity of C4a is 2000-fold weaker than C5a and 100-fold weaker than that of C3a. Due to these differences the role of C4a in these responses in vivo is thought to be negligible.AssaysTwo well established assays for C4a and C3a functional activities include induction of contraction in the guinea pig ileum and the permeation of a dye such as trypan blue from the vasculature into skin. The anaphylatoxins also induce mast cell degranulation, (measured as histamine release), platelet aggregation, IL-1 release from monocytes and the release of prostaglandins and leukotrienes from many cells and tissues. The other assays used for C3a (Dodds, A.W. and Sim, R.B. (1997)) should also respond to C4a, but few reports have described utilizing these assays with C4a. ELISA kits for the assay of C4a levels (or more correctly C4a desArg levels) in blood and other fluids are sold by several companies. These measurements are useful for detecting complement activation in vivo, but the interpretation of their meaning is complicated by the fact that clearance of the anaphylatoxins is rapid. In vivoFreshly drawn normal human serum contains significant levels of all three anaphylatoxins. Although these may represent the resting concentration in vivo it is difficult to draw or store blood without some complement activation so a true in vivo concentration is difficult to determine. The presence of EDTA and Futhan in the collection tubes can minimize this background (Pfeifer, P.H. et al. (1999)). Full activation of all C4 in blood (600µg/mL) would result in ~3,400 nM C4a (~30 µg/mL). Due to the low biological activity of C4a it could require activation of most of the C4 in a small region to achieve the micromolar C4a concentrations necessary to elicit a response.RegulationC4a levels are regulated by three processes: formation, inactivation and clearance. There are two enzymes that cleave C4 and release C4a: C1s and MASP-2. C4a is “inactivated” by removal of its C-terminal arginine amino acid. The product C4a desArg (or C4a without the C-terminal arginine) is produced by the action of the plasma enzyme carboxypeptidase N (Mueller-Ortiz S.L. et al. (2009)). The inactivation is rapid and most C4a is converted to C4a desArg within minutes of its formation. Inactivated C4a lack measurable biological activity. Because of the large number of cells bearing C3a/C4areceptors (endothelial, immune, smooth muscle, neuronal, etc.) the capture, internalization and digestion of C4a and C4a desArg probably results in its removal from circulation.DeficienciesA deficiency of C4 or a deficiency of all of the enzymes that cleave C4 to generate C4a could result in the absence of C4a. There are no known complete deficiencies of all ofthe C4 cleaving enzymes. Examples of C4 deficient humans and mice exist (Wessels, M.R. et al. (1995)), but the degree to which pathologies associated with C4 deficiency are due to the lack of C4 or the absence of C4a is unclear. DiseasesThere are no known diseases connected to C4a or C4a desArg. Precautions/Toxicity/HazardsThe source of C4a is human serum, therefore appropriate precautions must be observed even though the source was shown by certified tests to be negative for HBsAg, HTLV-I/II, STS, and for antibodies to HCV, HIV-1 and HIV-II.Injection can cause anaphylatic shock which is a generalized circulatory collapse similar to that caused by an allergic reaction.Hazard Code: B WGK Germany 3... Read More | Inquire | Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw Products contentN665730Component24 T96 TStorageN665730ATPS V50 144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730B5×FA Reaction Buffer144 µL576 µL-20℃. Avoid freeze/thaw cycle.N665730C2×HiFidelity PCR Mix600 µL2×1.2 mL-20℃. Avoid freeze/thaw cycle.N665730DPPM48 µL192 µL-20℃. Avoid freeze/thaw cycle.* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries. Products IntroductionThis kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction. Product Features ● DNA fragmentation and junction ligation in one step.● Ultra-fidelity amplification minimizes amplification-preferred steps.Provide your own instruments, kits and consumables1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification and recovery kit: It is recommended to use DNA purification and recovery kit by magnetic bead method.3. Library PCR primer kits: transposase method for second-generation sequencing multi-sample primer kits are recommended. 4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples. Pre-experiment Preparation and Important Notes1. Avoid repeated freezing and thawing of reagents.2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.Sample PreparationDNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).Schematic diagram of DNA banking processprocedureDNA fragmentation, junction reaction1. Add the following reagents to a 200 µl PCR tube: 2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.to prevent smaller library fragments due to DNA over-fragmentation. Purification of fragmentation productsWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Add 50 µl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 µlddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 µl of supernatant to a new 200 µl PCR tube.PCR amplification Add the following reagents to the 200 µl PCR tube: Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:Selective recovery of library DNA fragmentsIt is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 µl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.Note: Do not discard the top clear.4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.Note: Do not discard the beads.6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.7. Repeat step 6 once.8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave brieflycentrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube. Table: Suggested amount of magnetic beads for different segment selection recoveryLibrary DNA fragment purificationWe recommend the use of the Century Magnetic Bead Method DNA Purification and Recovery Kit.1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.2. 50 µl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 µl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.Note: When adding ethanol, the liquid must not be blown directly onto the beads.5. Repeat step 4.6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 µl of ddH2O to solubilize.Note: Do not over-dry the beads as this may affect the elution efficiency.7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.Library quality controlDetermination of library concentrationIn order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-timePCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library. Average total length of librariesApproximate conversion formula Library fragment distributionThe prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.Range of segment length distributions... Read More |