| Description | HABP4 Human Pre-designed siRNA Set A contains three designed siRNAs for HABP4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components HABP4 siRNA-1: 5 nmol (HPLC) HABP4 siRNA-2: 5 nmol (HPLC) HABP4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control:HABP4 Human Pre-designed siRNA Set A contains three designed siRNAs for HABP4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components HABP4 siRNA-1: 5 nmol (HPLC) HABP4 siRNA-2: 5 nmol (HPLC) HABP4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Inquire | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | Purity>97% SDS-PAGE.FunctionReceptor for interleukin-2 | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |