| Description | DNMBP Human Pre-designed siRNA Set A contains three designed siRNAs for DNMBP gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components DNMBP siRNA-1: 5 nmol (HPLC) DNMBP siRNA-2: 5 nmol (HPLC) DNMBP siRNA-3: 5 nmol (HPLC) siRNA Negative Control:DNMBP Human Pre-designed siRNA Set A contains three designed siRNAs for DNMBP gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components DNMBP siRNA-1: 5 nmol (HPLC) DNMBP siRNA-2: 5 nmol (HPLC) DNMBP siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Taq MasterMix is a premixed system composed of Taq DNA Polymerase, Mg2+, dNTPs, as well as PCR stabilizers and enhancers, with a concentration of 2 ×. The pre prepared PCR mixture makes the operation simpler and faster, and can minimize human error and contamination to the greatest extent Taq MasterMix is a premixed system composed of Taq DNA Polymerase, Mg2+, dNTPs, as well as PCR stabilizers and enhancers, with a concentration of 2 ×. The pre prepared PCR mixture makes the operation simpler and faster, and can minimize human error and contamination to the greatest extent possible. The original MasterMix formula results in high yield, strong repeatability, and good stability of amplified products. This product has been added with a dye (blue), and can be directly subjected to electrophoresis detection after the reaction is completed. The amplified PCR product has an "A" base attached to its 3 'end, making it suitable for direct use in T/A cloning. Mainly suitable for PCR amplification of DNA, DNA sequencing and other experiments. T665590Component5 mL25 mLStorageT665590A2×Taq MasterMix (Dye)5×1 mL5×5 mL-20℃. Avoid freeze/thaw cycle.T665590BddH₂O5×1 mL5×5 mL-20℃. Avoid freeze/thaw cycle.2×Taq MasterMix contains Taq DNA Polymerase, 3 mM Mg Cl₂ and 400 µM each dNTP. Quality control:After testing, there was no exogenous nuclease activity; PCR method for detecting residual DNA without host; Can effectively amplify single copy genes from multiple genomes.Usage:The following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template. In practical operation, corresponding improvements and optimizations should be made based on the template, primer structure, and target fragment size.1. PCR reaction system Reagent 50 µlReaction system Final concentration 2×Taq MasterMix(Dye) 25 µL 1× Forward Primer,10 µM 2 µL 0.4 µM Reverse Primer,10 µM 2 µl 0.4 µM Template DNA <0.5 µg <0.5 µg/50 µL ddH2O up to 50 µL /Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.2. PCR reaction conditions Step Temperature Time / Pre denaturation 94℃ 2 min / Denaturation 94℃ 30 s 25-35 cycles Anneal 55-65℃ 30 s 25-35 cycles Extend 72℃ 30 s 25-35 cycles Finally extended 72℃ 2 min / Attention:1) In general experiments, if the annealing temperature is 5 ° C lower than the melting temperature Tm of the amplification primer, and the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time should be set according to the size of the amplified fragment. The amplification efficiency of Taq DNA Polymerase in this product is 2 kb/min.3) The number of cycles can be set based on the downstream application of the amplification product. If the number of cycles is too small, the amplification amount is insufficient; If there are too many cycles, the probability of mismatches will increase, and non-specific backgrounds will be severe. So, while ensuring product yield, the number of cycles should be minimized as much as possible... Read More | C1q separated from C1r and C1s and from other stabilizing proteins tends to aggregate easily. Because it was isolated and studied in numerous research laboratories, many buffers have been used to stabilize concentrated C1q and prevent aggregation. About half of the scientists prefer high salt and C1q separated from C1r and C1s and from other stabilizing proteins tends to aggregate easily. Because it was isolated and studied in numerous research laboratories, many buffers have been used to stabilize concentrated C1q and prevent aggregation. About half of the scientists prefer high salt and the other prefer 40% glycerol in the storage buffer.C1q is purified from pooled normal human plasma. C1q is part of the C1 complex and this complex is the first complement component in the cascade referred to as the classical pathway of complement. C1 is actually a non-covalent assembly of three different proteins (C1q, C1r, and C1s) bound together in a calcium-dependent complex. C1q has six extended arms with domains at the end of each arm that bind to the Fc domains of immunoglobulins. When antibodies bind to antigens forming immune complexes they cluster allowing two or more of its six arms of C1q to bind to the Fc domains of antibodies such as IgG or IgM. The binding of multiple arms to immune complexes causes the two C1r proteins in the complex (protease zymogens) to auto-activate producing two C1r proteases that cleave and activate the two C1s protease zymogens in the complex. Activated C1s cleaves complement component C4 releasing C4a and initiating covalent attachment of C4b to the activating surface. Activated C1s also cleaves C2 and the larger fragment of C2 binds to the surface-attached C4b forming C4b,C2a which is the C3/C5 convertase of the classical pathway.Extinction Coeff.A₂₈₀ nm = 0.68 at 1.0 mg/ml for pure C1q Molecular weight:410,000 Da (18 chains)Preservative:None, 0.22 µm filtered.Source:Normal human serum (shown by certified tests to be negative for HBsAg, HTLV-I/II, STS, and for antibodies to HCV, HIV-1 and HIV-II).Physical Characteristics & StructureC1q is a high molecular weight complex of 18 polypeptide chains. Each of the six arms of C1q contains three chains, an A chain (26,000 daltons), a B chain (25,000 daltons) and a C chain (24,000 daltons). The three chains are coiled into a collagen-like triple helix over approximately half their length. Half of this collagen region forms a central core where all 18 chains come together. The chains are joined in this core by disulfides in the pattern A-B and C-C. There is a bend in the center of the collagen region allowing the arms to extend away from each other. Globular heads at the far ends of the collagen arms possess binding sites for Fc domains of immunoglobulins. C1 complex is composed of one C1q molecule (410,000 daltons), two C1r molecules (92,000 daltons) and two C1s molecules (86,000 daltons). The complex is stable in the presence of calcium, but easily dissociates if calcium is removed. When C1 is activated the C1r and C1s subunits are each cleaved into two chain molecules due to proteolytic activation. Thus, the SDS gel pattern of C1 is very complex. Function The biological functions of C1q are described above in the General Description and Physical Characteristics sections. C1q functional activity may be assayed using C1q-depleted serum and EA cells. These assays are extremely sensitive to C1q typically yielding 50% lysis with less than 2 ng C1q in assays measuring the lysis of EA cells. AssaysThe unit of classical pathway activity is the CH50. A similar unit, the C1qH50, is used to quantitate the activity of C1q. A C1qH50 unit is the amount of functional C1q needed to lyse 50% of 3×10^7 EA cells (antibody-sensitized sheep erythrocytes) when that amount of C1q is incubated with 5-20 µL of C1q-Dpl in GVB++ in a total volume of 500 µL for 30 min at 37℃. This amount of C1q indicates the sensitivity of the assay for C1q which is typically about 1 ng C1q with 10 µL C1q-Dpl. See the Certificate of Analysis for lot specific values.ApplicationsC1q is used to coat ELISA plates to capture and quantitate immune complexes in clinical samples. A number of commercial companies sell diagnostic kits for immune complex detection and quantitation. These kits are based on the ability of C1q to bind well to immune complexes, but to not bind significantly to monomeric immunoglobulins. GeneticsThe EMBL/Genbank cDNA accession numbers are: C1q A chain (P02745), C1q B chain (P02746), and C1q C chain (P02747). The genes for C1q chains A, B and C are all located on chromosome 1p in the order A-C-B. DeficienciesDeficiencies of each of the three components of C1 have been found. Patients lacking C1q generally have immune-complex-mediated renal disease and skin lesions. Like all patients lacking early classical pathway components C1q deficient individuals are prone to systemic lupus erythrematosis (SLE) and recurrent pyogenic infections. They lack classical pathway function and may or may not exhibit C1q antigen in blood.DiseasesSee section titled Deficiencies above. Precautions/Toxicity/HazardsThis protein is purified from human serum and therefore precautions appropriate for handling any blood-derived product must be used even though the source was shown by certified tests to be negative for HBsAg, HTLV-I/II, STS, and for antibodies to HCV, HIV-1 and HIV-II... Read More | Inquire | Inquire |