| Description | ELP4 Human Pre-designed siRNA Set A contains three designed siRNAs for ELP4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ELP4 siRNA-1: 5 nmol (HPLC) ELP4 siRNA-2: 5 nmol (HPLC) ELP4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 ELP4 Human Pre-designed siRNA Set A contains three designed siRNAs for ELP4 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ELP4 siRNA-1: 5 nmol (HPLC) ELP4 siRNA-2: 5 nmol (HPLC) ELP4 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Source: Microorganism Isoelectric point: 6.5 Michaelis constant: 9.2×10^-3 M (D-Glucose); 8.6×10^-3 M (NAD) Optimum pH: 9.0~9.5 Fig. 1Optimum temperature: 55℃ Fig. 3pH Stability: 6.0-10.0 (25℃, 24hr) Fig. 2Thermal stability: <50℃ (pH 8.0, Source: Microorganism Isoelectric point: 6.5 Michaelis constant: 9.2×10^-3 M (D-Glucose); 8.6×10^-3 M (NAD) Optimum pH: 9.0~9.5 Fig. 1Optimum temperature: 55℃ Fig. 3pH Stability: 6.0-10.0 (25℃, 24hr) Fig. 2Thermal stability: <50℃ (pH 8.0, 30min) Fig. 4Inhibitors: NEM,SDS Effect of various chemicals: Table 1Reaction:... Read More | Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the Product introduction:Used to isolate lymphocytes from human organsMatters needing attention:1. samples, reagents and experimental environment in the whole process shall be carried out at 20 ± 2 ℃. In order to obtain the best experimental results, it is best to carry out the experiment within 2 h of sampling. The longer the sample is stored, the worse the cell separation effect is. The separation effect is even worse after the sample is placed for more than 6 h, or even cannot achieve the purpose of separation. 2. in this experiment, it is better not to use plastic products with high polymerization materials (such as polystyrene), but use non-static, low static ionization heart tubes and glass products without alkali treatment, because the electrostatic effect will lead to cell adhesion, and the surface of alkali treated glass will become rough, which will affect the effect of cell separation. 3. aspirating too many lymphocyte layers and separation liquid layers will cause the granulocytes at the junction of separation liquid to be aspirated, thus increasing the number of mixed granulocytes. 4. when the amount of separating solution is greater than that of tissue single cell suspension sample, the separation effect is better.Scope of application:Lymphocyte isolation... Read More | H-7 dihydrochloride blocks human immunodeficiency virus (HIV-1) replication in MOLT-4 (clone No. 8) cell line. It increases the secretion of interleukin 1β (IL-1β).Application:H-7 dihydrochloride has been used to study H-7-induced inhibition of contractility in rat embryo H-7 dihydrochloride blocks human immunodeficiency virus (HIV-1) replication in MOLT-4 (clone No. 8) cell line. It increases the secretion of interleukin 1β (IL-1β).Application:H-7 dihydrochloride has been used to study H-7-induced inhibition of contractility in rat embryo fibroblasts (REF52) cells and acts as a kinase inhibitor... Read More | Inquire |