| Description | CDK5RAP2 Human Pre-designed siRNA Set A contains three designed siRNAs for CDK5RAP2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components CDK5RAP2 siRNA-1: 5 nmol (HPLC) CDK5RAP2 siRNA-2: 5 nmol (HPLC) CDK5RAP2 siRNA-3: 5 nmol (HPLC) siRNA CDK5RAP2 Human Pre-designed siRNA Set A contains three designed siRNAs for CDK5RAP2 gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components CDK5RAP2 siRNA-1: 5 nmol (HPLC) CDK5RAP2 siRNA-2: 5 nmol (HPLC) CDK5RAP2 siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Protein Purity>90 % by SDS PAGEExtinction CoeffA280 nm = 0.725 at 1.0 mg/mL for pure C1s-C1INH ComplexMolecular Weight196,000 Da (1 chain)General DescriptionThe product C1s-C1INH Complex is made by interacting purified protease inhibitor C1-INH with purified C1s enzyme followed by purification. Protein Purity>90 % by SDS PAGEExtinction CoeffA280 nm = 0.725 at 1.0 mg/mL for pure C1s-C1INH ComplexMolecular Weight196,000 Da (1 chain)General DescriptionThe product C1s-C1INH Complex is made by interacting purified protease inhibitor C1-INH with purified C1s enzyme followed by purification. The protease inhibitor C1-INH prevents the spontaneous activation of complement and limits consumption of C2 and C4 by rapidly inactivating C1r, C1s and MASP2. It is the only plasma serine protease inhibitor (Serpin) capable of interacting with and inhibiting activated C1. C1-INH interacts with the catalytic sites of both C1r and C1s. The interaction with activated C1r and C1s is covalent resulting in complexes which are stable to SDS. C1s and C1r enzymes, however, are irreversibly inactivated by binding to C1-INH. C1s-C1INH is a very stable complex that remains intact even when subjected to freeze/thaw cycles with almost no loss of the complex form.Physical Characteristics & StructureThe C1s enzyme-C1INH complex is composed of two disulfide linked chains from C1s enzyme (A chain 58,000 Da and B chain 28,000 Da) and one covalently linked chain from C1-INH (75,000 Da).SDS-PAGE analysis of the C1s-C1INH complex shows a single band of about 161,000 Da under nonreducing conditions. Under reducing conditions, the C1s-C1INH complex exhibits two bands: A 58,000 Da band corresponding to the A chain of C1s enzyme and a second 103,000 Da band resulting from C1INH (75,000 Da) covalently bond to the B chain (28,000 Da) of C1s enzyme.RegulationActivated C1s is controlled by C1-INH. C1s enzyme and C1-INH form a covalent complex that is resistant to separation on SDS gels. During complement activation C1 complex is rapidly activated by binding to immune complexes. The resulting activated C1s and C1r are rapidly inactivated by interaction with C1-INH (Ziccardi, R.J. (1982)). Binding to immune complexes is fast (10-20 sec) and activation of the bound C1 complex takes several minutes, but C1-INH has also been shown to be fast and no active C1r or C1s remain 4 min after addition of immune complexes to plasma (Ross, G.D. (1986); Ziccardi,R.J. (1981)). The binding of C1-INH to activated C1 releases both C1r and C1s from the complex leaving C1q bound to the immune complex. The released complexes contain four molecules: C1-INH-C1r-C1s-C1-INH. The reaction of C1 esterase inhibitor with activated C1 is very fast with the estimated half-life of C1r and C1s being approximately 15 seconds in serum. In fact, at serum concentrations of C1- INH little or no additional C4 or C2 activation occurs 3 min after immune complexes are added because all the C1r and C1s molecules have been inactivated and removed from the C1q which remains bound to the immune complex (Ross, G.D. (1986); Morley, B.J. and Walport, M.J. (2000); Rother, K., et al. (1998); Ziccardi, R.J. (1982a and 1982b); Morgan, B.P. (1990)). The interaction of purified C1s enzyme and C1-INH is slower.FunctionSee General Description and Regulation above.ApplicationsC1s-C1INH complex can be used in studies designed for developing and identifying inhibitors of C1s-C1INH complex formation and thus lead to the possible development of therapeutics for inhibiting complement activation via the classical pathway.GeneticsThe EMBL/Genbank cDNA accession number for C1s is J04080. The gene for C1s is located on chromosome 12p13. The EMBL/Genbank cDNA accession numbers for C1-INH are M13656 and X54486 (human) and Y10386 (mouse). The gene for C1-INH is located on chromosome 11p11.2-13. DeficienciesC1s deficient patients are prone to systemic lupus erythematosus (SLE) and recurrent pyogenic infections (Rother, K., et al. (1998)). They lack classical pathway function. The genetic disorder hereditary angioedema (HAE) is caused by a partial deficiency of C1-INH. Patients with HAE have low functional C1-INH levels in blood and have recurrent episodes of systemic or localized edema.DiseasesSee section titled Deficiencies above. Precautions/Toxicity/HazardsThis protein is purified from human serum and therefore precautions appropriate for handling any blood-derived product must be used even though the source was shown by certified tests to be negative for HBsAg, HTLV-I/II, STS, and for antibodies to HCV, HIV-1 and HIV-II.ReferencesZiccardi, RJ. (1982) A new role for C-1-inhibitor in homeostasis: control of activation of the first component of human complement. J. Immunol. 128:2505-2508.Ross, G.D. (1986) Immunobiology of the Complement System. (ISBN 0-12-5976402) Academic Press, Orlando.Ziccardi, R.J. (1981) Activation of the early components of the classical complement pathway under physiologic conditions. J. Immunol. 126:1769-1773.Morley, B.J. and Walport, M.J. (2000) The Complement Facts Book. (ISBN 0127333606) Academic Press, London.Rother, K., Till, G.O., and Hӓnsch, G.M. (1998) The Complement System. (ISBN 3-540- 61894-5) Springer-Verlag, Heidelberg.Ziccardi, R.J. (1982a) Spontaneous activation of the first component of human complement (C1) by an intramolecular autocatalytic mechanism. J. Immunol. 128:2500- 2504.Ziccardi, RJ. (1982b) A new role for C-1-inhibitor in homeostasis: control of activation of the first component of human complement. J. Immunol. 128:2505-2508. Morgan, B.P. (1990) Complement Clinical Aspects and Relevance to Disease. (ISBN 0- 12-506955-3) Academic Press, London... Read More | ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology ProductsThis product is a high purity genomic DNA extract from 293T cells, agarose gel (0.7%) electrophoresis showed that the size of the DNA extract is more than 15Kb, and basically no degradation, the product is ultimately preserved in TE Buffer, which can be widely used in molecular biology experiments, such as PCR, enzyme digestion, hybridization, microarray analysis, and other molecular biology experiments.The product was quantified using NanoDrop One at a concentration of 200 ng/µL.Preparation and precautions before useLong-term storage at -20˚C is recommended. Before use, the bottle should be removed from the refrigerator and equilibrated to room temperature and centrifuged before opening the cap for use. Samples should be restored to the sealed state as soon as possible after opening.How to use (take qPCR experiment as an example)1. Amplification template preparationThe samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0,1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/µL. The samples were placed on ice at 4°C and set aside.2. Standard dilution: according to the following table, firstly dilute Human DNA Standard 1 (100ng/uL) with TE to make 5 different concentrations of standards according to the table below. 10ng/µL of DNA Standard 1 (Std. 1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When not used temporarily after preparation, it should be stored at 4℃ or on ice.styleCorresponding concentration (ng/µL)Minimum dilution volume (in µL)Std.11010 [100 ng/µL DNA Standard 1] + 90 TEStd.22.520 [Std. 1] +60 TEStd.30.62520 [Std. 2] +60 TEStd.40.1562520 [Std. 3] +60 TEStd.50.039062520 [Std. 4] +60 TE3. qPCR reaction system preparationThe cryopreserved reagents to be used were completely thawed and mixed by inversion several times before preparation, and then briefly centrifuged and prepared for use. 20 µL of the base reaction system was as follows.The base reaction system for 20 µL was as follows:reagents20µL reaction system2×qPCRMix10µLPrimerMixXµLProbeMixXµLTemplate4µLddH2OMake up to 20 µLNote: High Rox model: add 1 µL of 50×High Rox per 50 µL of reaction system; Low Rox model: add 1 µL of 50×High Rox per 500 µL of reaction system.Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.The concentration of the probe used is related to the fluorescent quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, so please refer to the manual of the instrument or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration during actual use.Prepare a sufficient amount of reaction system mixture as required. After the reaction system has been prepared and mixed thoroughly, add 16 µL per well to the reaction wells. Then add the prepared standard and diluted sample into the corresponding reaction wells, the volume of addition is 4µL/well. TE was added to the blank control tube, and the same amount of TE was added at 4 µL/well.It is recommended to use 20 µL for the reaction, if you need to perform a smaller system reaction, reduce the system components in equal proportion.4. qPCR reaction programThe following is an example of our GoldStar Probe Mixture reaction conditions, which should be improved and optimized according to the PCR product template, primer structure and target fragment size.movetemptimingcirculatepremutability95°C10min1denaturation95°C10sec55Annealing/Extension60°C30sec5Data analysis1. Standard curve productionThe standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should not be lower than 0.98, and the slope should be between -3.1 and -3.6 when the Ct value is the vertical coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment... Read More | Purity:>95%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:HSPD1, also known as HSP60, is a member of the chaperonin family. HSPD1 may function as a signaling molecule in the innate immune system. This protein is essential for the folding and assembly of newly Purity:>95%, by SDS-PAGE visualized with Coomassie® Blue Staining.Description:HSPD1, also known as HSP60, is a member of the chaperonin family. HSPD1 may function as a signaling molecule in the innate immune system. This protein is essential for the folding and assembly of newly imported proteins in the mitochondria. It may also prevent misfolding and promote the refolding and proper assembly of unfolded polypeptides generated under stress conditions in the mitochondrial matrix. HSPD1 gene is adjacent to a related family member and the region between the 2 genes functions as a bidirectional promoter. Several pseudogenes have been associated with this gene. Mutations associated with this gene cause autosomal recessive spastic paraplegia 13. Defects in HSPD1 are a cause of spastic paraplegia autosomal dominant type 13 (SPG13). Spastic paraplegia is a degenerative spinal cord disorder characterized by a slow, gradual, progressive weakness and spasticity of the lower limbs. Defects in HSPD1 are the cause of leukodystrophy hypomyelinating type 4 (HLD4); also called mitochondrial HSP60 chaperonopathy or MitCHAP-60 disease. HLD4 is a severe autosomal recessive hypomyelinating leukodystrophy. HSPD1 is clinically characterized by infantile-onset rotary nystagmus, progressive spastic paraplegia, neurologic regression, motor impairment, profound mental retardation. Death usually occurs within the first two decades of life... Read More | This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked This reagent kit is based on TRIzon's improved columnar total RNA extraction kit. This product can be extracted from animal groupsExtract total RNA from samples such as textiles, plant materials, various microorganisms, and cultured cells. Firstly, the cracking solution is fully cracked andHomogenized samples, in their unique high salt state, RNA specifically binds to silicon matrix membranes, greatly reducingEffectively removing organic solvent contamination while removing protein contamination, resulting in higher purity and quality of RNA. bookThe product can quickly extract total RNA from various cells or tissues, and can process 30-50 mg of tissue or 5 × 10 ⁶ cells each time,Can handle multiple different samples simultaneously. If it is an RNA experiment that is very sensitive to trace amounts of DNA, the residual DNA can be utilizedUsing DNase without RNase for digestion and removal on the column, the extracted RNA can be directly applied to RT-PCR Experiments such as Northern Blot, Dot Blot, and in vitro translation. U665516 Component 50 T Storage U665516A DNase I 1000 U -20℃. Avoid freeze/thaw cycle. U665516B 10×Reaction Buffer 1000 µL -20℃. Avoid freeze/thaw cycle. U665516C TRIzon Reagent 60 mL 2-8℃. Protect from light. U665516D TRIzon PaI™ 10 mL 2-8℃. Protect from light. U665516E Buffer RW1 40 mL RT U665516F Buffer RW2 (concentrate) 11 mL RT U665516G RNase-Free Water 10 mL RT U665516H Spin Columns RM with Collection Tubes 50 sets RT U665516I RNase-Free Centrifuge Tubes (1.5 mL) 50 EA RTPreparation and important precautions before the experiment:1.To prevent RNase pollution, attention should be paid to the following aspects:1) RNase's plastic products and gun heads to avoid cross contamination.2) Prepare the solution using water without RNase.3) Operators should wear disposable masks and gloves, and change gloves frequently during the experiment.2. The sample should avoid repeated freezing and thawing, otherwise it will affect the yield and quality of RNA extraction.3. If TRIzon Reagent is found to have precipitates before use, it can be dissolved in a water bath at 56 ℃ for a few minutes.Before the first use, anhydrous ethanol should be added to Buffer RW2 according to the instructions on the reagent bottle label.5. All centrifugation steps should be carried out at room temperature unless otherwise specified, and all operation steps should be carried out quickly.Usage:1. Sample processing1a. Organization: 30-50 mg of tissue is thoroughly ground in liquid nitrogen and 1 mL of TRIzon Reagent is added, or 1 mL of TRIzon Reagent is added to the tissue sample and homogenized. Attention: The sample volume should not exceed 10% of the volume of TRIzon Reagent.2a. Single layer cell culture: Remove the culture medium and add an appropriate amount every 10 cm ² Add 1 mL of TRIzon Reagent.3a. Cell suspension: Collect cells by centrifugation. Add 1 mL of TRIzon Reagent to every 5 × 10 µ m cell.2. After adding TRIzon Reagent, repeatedly blow a few times to fully crack the sample. Leave at room temperature for 5 minutes to completely separate the protein nucleic acid complex.3. Add 200 to every 1 mL of TRIzon Reagent µ LTRIzon PaI ™, Cover the tube tightly, vigorously shake for 15 seconds, and let it sit at room temperature for 2 minutes.4. Centrifuge at 4 ℃ 12000 rpm (~13400 × g) for 10 minutes. At this time, the sample is divided into three layers: the red organic phase, the middle layer, and the upper colorless aqueous phase. RNA is mainly in the upper aqueous phase. Move the upper aqueous phase to a new RNase Free centrifuge tube (provided).5. Add an equal volume of 70% ethanol (prepared without RNase water) to the obtained aqueous solution, invert and mix well.6. Add all the solutions obtained in the previous step to the spin columns RM that have been loaded into the collection tube. If the solution cannot be added at once, it can be transferred in multiple batches. Centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.7. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.8. Preparation of DNase I mixture: Take 52 µ LRNase Free Water, add 8 to it µ L 10 x Reaction Buffer and 20 µ L DNase I (1 U/ µ L) Mix well and prepare to a final volume of 80 µ The reaction solution of L.9. Directly add 80 µ L DNase I mixture to the adsorption column and incubate at 20-30 ℃ for 15 minutes.10. Add 350 to the adsorption column µ L Buffer RW1, centrifuge at 12000 rpm for 1 minute, discard the waste liquid, and place the adsorption column back into the recovery manifold.11. Add 500 to the adsorption column µ L Buffer RW2 (check if anhydrous ethanol has been added before use), centrifuge at 12000 rpm for 20 seconds, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.12. Repeat step 11.Centrifuge at 12000 rpm for 2 minutes and discard the waste liquid from the collection tube. Place the adsorption column at room temperature for a few minutes and thoroughly air dry. Attention: The purpose of this step is to remove residual ethanol from the adsorption column, which will affect subsequent enzymatic reactions (enzyme digestion,. )PCR, etc.14. Place the adsorption column in a new RNase free centrifuge tube and add 30-50 to the middle of the adsorption column µ Place RNase Free Water at room temperature for 1 minute, centrifuge at 12000 rpm for 1 minute, collect RNA solution, and store RNA at -70 ℃ to prevent degradation.Attention:1) The volume of RNase Free Water should not be less than 30 µ L. Small volume affects the recovery rate.2) If you want to increase RNA production, you can use 30-50 µ Repeat step 14 for the new RNase Free Water.3) If you want to increase the RNA concentration, you can add the obtained solution back to the adsorption column and repeat step 14... Read More |