| Description | ARSG Human Pre-designed siRNA Set A contains three designed siRNAs for ARSG gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ARSG siRNA-1: 5 nmol (HPLC) ARSG siRNA-2: 5 nmol (HPLC) ARSG siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 ARSG Human Pre-designed siRNA Set A contains three designed siRNAs for ARSG gene (Human), as well as a negative control, a positive control, and a FAM-labeled negative control. Components ARSG siRNA-1: 5 nmol (HPLC) ARSG siRNA-2: 5 nmol (HPLC) ARSG siRNA-3: 5 nmol (HPLC) siRNA Negative Control: 5 nmol (HPLC) FAM-labeled siRNA Negative Control: 5 nmol (HPLC) GAPDH siRNA Positive Control:5 nmol (HPLC)... Read More | Taq MasterMix is a premixed system composed of Taq DNA Polymerase, Mg2+, dNTPs, as well as PCR stabilizers and enhancers, with a concentration of 2 ×. The pre prepared PCR mixture makes the operation simpler and faster, and can minimize human error and contamination to the greatest extent Taq MasterMix is a premixed system composed of Taq DNA Polymerase, Mg2+, dNTPs, as well as PCR stabilizers and enhancers, with a concentration of 2 ×. The pre prepared PCR mixture makes the operation simpler and faster, and can minimize human error and contamination to the greatest extent possible. The original MasterMix formula results in high yield, strong repeatability, and good stability of amplified products. This product has been added with a dye (blue), and can be directly subjected to electrophoresis detection after the reaction is completed. The amplified PCR product has an "A" base attached to its 3 'end, making it suitable for direct use in T/A cloning. Mainly suitable for PCR amplification of DNA, DNA sequencing and other experiments. T665590Component5 mL25 mLStorageT665590A2×Taq MasterMix (Dye)5×1 mL5×5 mL-20℃. Avoid freeze/thaw cycle.T665590BddH₂O5×1 mL5×5 mL-20℃. Avoid freeze/thaw cycle.2×Taq MasterMix contains Taq DNA Polymerase, 3 mM Mg Cl₂ and 400 µM each dNTP. Quality control:After testing, there was no exogenous nuclease activity; PCR method for detecting residual DNA without host; Can effectively amplify single copy genes from multiple genomes.Usage:The following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template. In practical operation, corresponding improvements and optimizations should be made based on the template, primer structure, and target fragment size.1. PCR reaction system Reagent 50 µlReaction system Final concentration 2×Taq MasterMix(Dye) 25 µL 1× Forward Primer,10 µM 2 µL 0.4 µM Reverse Primer,10 µM 2 µl 0.4 µM Template DNA <0.5 µg <0.5 µg/50 µL ddH2O up to 50 µL /Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration µ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.2. PCR reaction conditions Step Temperature Time / Pre denaturation 94℃ 2 min / Denaturation 94℃ 30 s 25-35 cycles Anneal 55-65℃ 30 s 25-35 cycles Extend 72℃ 30 s 25-35 cycles Finally extended 72℃ 2 min / Attention:1) In general experiments, if the annealing temperature is 5 ° C lower than the melting temperature Tm of the amplification primer, and the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.2) The extension time should be set according to the size of the amplified fragment. The amplification efficiency of Taq DNA Polymerase in this product is 2 kb/min.3) The number of cycles can be set based on the downstream application of the amplification product. If the number of cycles is too small, the amplification amount is insufficient; If there are too many cycles, the probability of mismatches will increase, and non-specific backgrounds will be severe. So, while ensuring product yield, the number of cycles should be minimized as much as possible... Read More | Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× Product contentG665787Component5 mLStorageG665787A2×GoldStar Probe Mixture (UNG)5×1 mL-20℃. Avoid freeze/thaw cycle.G665787B50×High ROX200 µL-20℃. Avoid freeze/thaw cycle.G665787CddH2O 5×1 mL -20℃. Avoid freeze/thaw cycle. Product Introduction2× GoldStar Probe Mixture (UNG) is a premixed system dedicated to real-time fluorescence quantitative PCR by probe method (TaqMan, Molecular Beacon, etc.), with a concentration of 2×, containing GoldStar Taq DNA polymerase, PCR Buffer, dNTPs (dTTP is all replaced by dUTP), UNG enzyme and Mg2+, which is easy and convenient to operate. It is mainly used for the detection of genomic DNA target sequences and cDNA target sequences after RNA reverse transcription, such as gene expression analysis, copy number analysis and SNP genotype analysis. This product utilizes the dUTP-UNG anti-pollution system, which adds dUTP during the preparation of the PCR reaction system, thus forming an amplification product containing dU bases. This product can be eliminated by the UNG enzyme in the PCR system before the next PCR reaction. This effectively removes residual contamination of the PCR product and greatly reduces false positives due to contamination of the amplification product.UNG enzyme can be inactivated at the pre-denaturation step in the PCR cycle, and therefore will not affect the formation of new PCR products containing dU bases. The GoldStar Taq DNA Polymerase contained in this product is a chemically modified, new high-efficiency hot-start enzyme, which has no polymerase activity at room temperature, effectively avoiding non-specific amplification due to non-specific binding of primers and templates or primer dimerization at room temperature, and the activation of the enzyme must be incubated at 95°C for 10 minutes. The unique combination of PCR buffer system and hot-start enzyme significantly improves the amplification efficiency of PCR with stronger fluorescent signal and higher sensitivity to detect single-copy templates. A wider linear range and more accurate quantification of the target gene can be obtained by using this product.ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.Instruments that do not require ROX calibration (G670150):Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96 and others.Instruments requiring Low ROX calibration(G665780):ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 system. Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and more.Instruments requiring High ROX calibration(G665787):ABI Prism 7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, and others.matters needing attentionBefore use, please mix gently by turning up and down, avoid foaming as much as possible, and use after brief centrifugation.Avoid repeated freezing and thawing of this product, repeated freezing and thawing may degrade the product performance. This product can be stored for long term at -20℃, protected from light. If frequent use is required within a short period of time, it can be stored at 2-8℃.UsageThe following examples are conventional PCR reaction systems and reaction conditions, which should be improved and optimized according to the template, primer structure and target fragment size in actual operation.1.PCR reaction systemReagents50 µl Reaction systemfinal concentration2×GoldStar Probe Mixture(UNG)25 µl1×Forward Primer,10 µM1 µl0.2 µM¹⁾Reverse Primer,10 µM1 µl0.2 µM¹⁾Probe,10 µM1 µl0.2 µM²⁾Template DNA2 µl³⁾ 50×Low ROX or High ROX(optional)⁴⁾1 µl1×ddH₂Oup to 50 µlNote: 1) Usually, better results can be obtained with a primer concentration of 0.2 µM, and 0.1-1.0 µM can be used as a reference for setting the range.(2) The concentration of the probe used is related to the fluorescence quantitative PCR instrument used, the type of probe, and the type of fluorescent labeling substance, please refer to the instrument manual or the specific requirements for the use of each fluorescent probe for the adjustment of the concentration in actual use.(3) Usually the amount of DNA template is 10-100ng genomic DNA or 1-10ng cDNA as a reference. Since the templates of different species contain different copy numbers of target genes, the templates can be subjected to gradient dilution to determine the optimal amount of template to be used.(4) The excitation optical system varies from instrument to instrument, choose to add 50×Low ROX or 50×High ROX according to the instrument using fluorescence quantification.2.PCR reaction programCaution! The pre-denaturation reaction of this product must be completed at 95°C for 10 minutes!Two-step PCR:Note: 1) The hot-start enzyme used in this product must be activated under the condition of pre-denaturation 95℃, 10min. 2) It is recommended to use two-step PCR reaction program, if you can't get good experimental results due to the use of primers with lower Tm value, etc., you can try to carry out three-step PCR amplification.Three-step PCR:... Read More | N-Acetylneuraminyl-fucosyllacto-N-neo-tetraose is used as a reference material in the analysis of milk oligosaccharides | Purity>98% SDS-PAGE. purified using conventional chromatography techniques.FunctionChemotactic activity for lymphocytes but not for monocytes or neutrophils.Chemokine (C motif) ligand (XCL1), as known as lymphotactin, is the only known member of the C-chemokine family and signals through the Purity>98% SDS-PAGE. purified using conventional chromatography techniques.FunctionChemotactic activity for lymphocytes but not for monocytes or neutrophils.Chemokine (C motif) ligand (XCL1), as known as lymphotactin, is the only known member of the C-chemokine family and signals through the receptor XCR1, formally known as GPR5. The expression of lymphotactin is abundant in some activated T cells such as activated CD8+ T cells and other class I MHC restricted T cells. It is found in high levels in spleen, thymus, intestine and peripheral blood leukocytes, and at lower levels in lung, prostate gland and ovary. XCL1 induces its chemotactic function by binding to a chemokine receptor called XCR1. Recombinant Human XCL1 which is a single non-glycosylated polypeptide chains containing 92 amino acids and it shares approximately 60 % amino acid sequence homology with the murine and rat protein... Read More |