| Ionization Method(s) | Matrix-Assisted Laser Desorption/Ionization | Direct Analysis in Real Time (DART) | ESI, DART, and CSI (ColdSpray) are supported | FI, FD
EI, PI, CI optional |
| Description | The JMS-S3000 SpiralTOF™-plus Ultra-High Mass Resolution MALDI-TOFMS* System is a MALDI-TOFMS that incorporates the innovative SpiralTOF ion optics. The JMS-S3000 has evolved into SpiralTOF™-plus 3.0 with much wider dynamic range. The JMS-S3000 defines a new standard in MALDI-TOFMS performance and The JMS-S3000 SpiralTOF™-plus Ultra-High Mass Resolution MALDI-TOFMS* System is a MALDI-TOFMS that incorporates the innovative SpiralTOF ion optics. The JMS-S3000 has evolved into SpiralTOF™-plus 3.0 with much wider dynamic range. The JMS-S3000 defines a new standard in MALDI-TOFMS performance and provides state-of-the-art analytical solutions for a wide range of research areas such as functional synthetic polymers, materials science, and biomolecules.
Key Features - SpiralTOF, TOF/TOF and Linear TOF analyzers
- Ultrahigh resolving power of >75,000 over wide mass range
- Sub-ppm mass accuracy with internal standard
- Mono isotopic precursor selection
- True high-energy (20 keV) CID
- Free of artifacts from post-source decay (PSD)
... Read More | Direct Analysis in Real Time DART - A Powerful Problem-solving Tool
The AccuTOF-DART 4G allows you to immediately determine chemical composition and produce high-resolution, accurate mass spectra by simply placing a sample in its native form between the DART ion source and the AccuTOF mass Direct Analysis in Real Time DART - A Powerful Problem-solving Tool
The AccuTOF-DART 4G allows you to immediately determine chemical composition and produce high-resolution, accurate mass spectra by simply placing a sample in its native form between the DART ion source and the AccuTOF mass spectrometer inlet. The DART source ionizes almost anything you put in front of it including solutions straight from your synthetic reaction pot, crude extracts, unknown pills or powders, polymers and adhesives, contamination on small parts, sticky liquids, vapors, TLC plates, and more. Many analyses can be carried out with little or no sample preparation.
The AccuTOF Advantage
The AccuTOF-DART is the perfect union of advanced time-of-flight mass spectrometer with the open air ion source that completely changed the field of mass spectrometry. Developed on the AccuTOF here at JEOL, the DART ion source is fully integrated with the mass spectrometer. No additional pumps, flanges, or interface hardware are required. This makes it possible to carry out unique ambient ionization experiments that are not practical on other mass spectrometers and produces clean, reproducible, easy-to-interpret data.
The third-generation AccuTOF-DART 4G system is an “ambient ionization toolbox†that allows the analyst to choose ionization methods that are best matched to the samples to be analyzed. The DART ion source can be operated on the AccuTOF-DART 4G in several different modes, plus a wide range of ambient ionization methods can be carried out without removing the DART ion source.... Read More | The basic system comes standard with an orthogonal spray ESI source. Optionally available ion sources include: APCI, Dual Spray ESI, Micro ESI, Nano ESI, and the revolutionary Direct Analysis in Real Time (DART). All sources are coupled to the AccuTOF via our unique atmospheric pressure interface. The basic system comes standard with an orthogonal spray ESI source. Optionally available ion sources include: APCI, Dual Spray ESI, Micro ESI, Nano ESI, and the revolutionary Direct Analysis in Real Time (DART). All sources are coupled to the AccuTOF via our unique atmospheric pressure interface. An integrated chassis consolidates all requisite spectrometer components, including pumps, into a compact benchtop footprint. This design not only saves space, but also ensures that temperature-sensitive components such as the flight tube remain under controlled conditions. From ion source to detector, the robust AccuTOF LC-plus 4G design makes high-resolution, high-sensitivity accurate mass analyses routine.
LC/MS
The AccuTOF LC-plus 4G is also a simple and robust LC/MS system. It offers a wide variety of applications for LC/MS with optional Atmospheric Pressure Chemical Ionization (APCI) source, in addition to the standard orthogonal ESI source. Accurate mass measurements in LC/MS can be made routine by automating the introduction of the internal mass reference compound with the optional Auto-Injection Valve.
Cold Spray
With the optional ColdSpray ion source, thermally labile analytes, including self-assembling supra molecules, some classes of organometallic complexes, short-chain double stranded DNAs, can all be analyzed intact. ColdSpray ionization was developed by Prof. Kentaro Yamaguchi, et al., of Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University (previously Chiba University) and the result of a project funded by the Japan Science and Technology Agency.... Read More | The JMS-T2000GC AccuTOF™ GC-Alpha Time-of-Flight Mass Spectrometer takes you to a new world of mass spectrometry, the ultimate GC-MS with superior performance and ease of operation.
The AccuTOF™ GC-Alpha is an orthogonal-acceleration time-of-flight mass spectrometer(oaTOFMS) with dualThe JMS-T2000GC AccuTOF™ GC-Alpha Time-of-Flight Mass Spectrometer takes you to a new world of mass spectrometry, the ultimate GC-MS with superior performance and ease of operation.
The AccuTOF™ GC-Alpha is an orthogonal-acceleration time-of-flight mass spectrometer(oaTOFMS) with dual stage reflectron. It employs an ideal ion optical system realizing both high ion transmission(=sensitivity) and ultra-high resolution.
The AccuTOF™ GC-Alpha is truly a high-performance GC-MS system that removes the limitations for chemical analysis.... Read More |