Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemThermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass SpectrometerThermo Scientific™ Exactive™ Plus EMR Orbitrap™ LC-MS SystemThermo Scientific™Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ LC-MS/MS Mass SpectrometerTSQ Altis™ MD Mass SpectrometerTSQ Quantis™ MD Mass Spectrometer
Citations
Catalog NumberIQLAAEGAAPFADBMBHQIQLAAEGAAPFALGMBDLIQLAAEGAAPFALGMBDKIQLAAEGAAXFAQSMBLCIQLAAEGAAXFAQTMBLA
Price
Ionization Method(s)HESIAPCI, H-ESIAPCI, H-ESIInquireInquire
Mass AnalyzerOrbitrapOrbitrapHybrid Quadrupole / OrbitrapTriple quadrupoleTriple quadrupole
Scanning SpeedInquireUp to 12 HzUp to 12 HzInquireInquire
Mass Rangem/z 50–2,000
m/z 200–4,000
up to m/z 6,000 without precursor ion selection (OTMS only)
350 to 20,000 m/z50 to 6,000 m/z5 to 3000 m/z5 to 3000 m/z
DescriptionExcel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. This... Read MoreWhile analysis of denatured proteins may be the most common LC/MS protein analysis, many biopharmaceutical and biological research applications require analysis of proteins in their native (intact) state. The Thermo Scientific™ Exactive™ Plus EMR mass spectrometer combines unsurpassed high-... Read MoreTake Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased ... Read MoreAchieve the sensitivity to perform routine quantitative analyses with remarkable speed and robustness. The Thermo Scientific™ TSQ Quantis™ MD Series mass spectrometer can be used by clinical diagnostic laboratories to meet their routine requirements for laboratory developed tests (LDTs). With Active... Read MoreDevelop in vitro diagnostic tests for demanding quantitative analyses leveraging the enhanced sensitivity and remarkable speed and robustness of the Thermo Scientific™ TSQ Altis™ MD Series Mass Spectrometer. The TSQ Altis MD Series mass spectrometer, a Class I medical device, offers superb ... Read More