Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemQ Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass SpectrometerThermo Scientific™ ISQ™ 7610 Single Quadrupole GC-MS SystemThermo Scientific™ ISQ™ EC Single Quadrupole Mass SpectrometerThermo Scientific™ TSQ™ 9610 Triple Quadrupole GC-MS/MS SystemTSQ Altis™ MD Mass Spectrometer
Citations
Catalog NumberIQLAAEGAAPFALGMAZRIQLAAAGAAJFALOMBNAIQLAAAGADIFZZZMZZZIQLAAAGABNFARPMBNBIQLAAEGAAXFAQSMBLC
Price
Ionization Method(s)InquireEI, FS, SIM, FS/SIM, CI, PCI, NCI, depending on modelAPI, HESIVaries by model, AEI, EI, CIInquire
Mass AnalyzerUHMR Hybrid Quadrupole-Orbitrap™Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 µASingle quadrupoleTriple quadrupoleTriple quadrupole
Scanning Speedup to 12 Hz at resolution setting of 12,500 at m/z 400InquireUp to 20,000 Da/sec.InquireInquire
Mass Range350 to 80,000 m/z1.2–1100 u with Unit Mass Resolution10 to 1250 m/zInquire5 to 3000 m/z
DescriptionThe Thermo Scientific™ Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ mass spectrometer is the first to provide the unique combination of unprecedented ultra-high mass range resolution, highest sensitivity, and MS2 and pseudo-MS3 capabilities needed to go beyond what’s possible with today’s native MS ... Read MoreDeveloped to enhance user experience in their workflows, the ISQ 7610 GC-MS system is streamlined to ensure great data consistency over time while offering automated instrument control tools.Add mass spectrometry (MS) to your IC and LC analyses for access to the valuable data that only MS can provide. The new, easy-to-use Thermo Scientific™ ISQ™ EC Single Quadrupole Mass Spectrometer seamlessly integrates with ion chromatography (IC) and high performance liquid chromatography (HPLC) ... Read MoreThe TSQ 9610 GC-MS/MS system is designed to revolutionize laboratory productivity by delivering unprecedented levels of performance and reduce cost per sample for the high-throughput environment.Achieve the sensitivity to perform routine quantitative analyses with remarkable speed and robustness. The Thermo Scientific™ TSQ Quantis™ MD Series mass spectrometer can be used by clinical diagnostic laboratories to meet their routine requirements for laboratory developed tests (LDTs). With Active... Read More