Description | The LCMS-9030 quadrupole time-of-fight (Q-TOF) mass spectrometer integrates the world’s fastest and most sensitive quadrupole technology with TOF architecture. A product of Shimadzu's engineering DNA, speed and effortless performance enable the LCMS-9030 to address qualitative and quantitative The LCMS-9030 quadrupole time-of-fight (Q-TOF) mass spectrometer integrates the world’s fastest and most sensitive quadrupole technology with TOF architecture. A product of Shimadzu's engineering DNA, speed and effortless performance enable the LCMS-9030 to address qualitative and quantitative challenges with genuine confidence and ease.
Reproducible Results
The LCMS-9030 Q-TOF delivers outstanding mass accuracy over a wide mass range, enabling users to consistently produce accurate identification results. In addition, the LCMS-9030 requires infrequent calibration, making it easy to achieve high mass accuracy over long periods.
High Sensitivity Detection
High efficiency ion guides, quadrupole, and collision cell enable high sensitivity for the detection of trace level compounds. And, due to its robust platform, the LCMS-9030 achieves reproducible quantitative analysis over longer periods of time.
Ultrafast Performance
The LCMS-9030 incorporates the patented ultrafast technologies used in Shimadzu LC-MS/MS platforms to deliver outstanding speed. Innovative TOF architecture enables precise, ultra-fast pulsing of ions into the flight tube and ideal reflection back to the detector. The result is high-speed data acquisition compatible with the high-throughput laboratory.
Compatibility with Multiple Ionization Units
In addition to the standard ESI ionization unit, optional APCI and Dual Ion Source (DUIS) probes are available. The DUIS offers an efficient combination of ESI and APCI ionization capabilities. In addition, a Micro-ESI 9030 interface brings microflow analysis to the LCMS-9030.
LabSolutions LCMS is your single point of control for UHPLC and Q-TOF mass spectrometry data acquisition and analysis. Qualitative and quantitative acquisition modes that fully utilize the capability of the LCMS-9030 are MS, SIM, MS/MS, MRM, and MS/MS (DDA).... Read More | Adopting a proprietary multi-function ion source and a new large-capacity turbomolecular pump with heightened exhaust efficiency for all carrier gases including nitrogen, the rugged, high-sensitivity GCMS-QP2020 NX elevates GCMS performance to a new level. New Quick-CI and Smart SIM functionality Adopting a proprietary multi-function ion source and a new large-capacity turbomolecular pump with heightened exhaust efficiency for all carrier gases including nitrogen, the rugged, high-sensitivity GCMS-QP2020 NX elevates GCMS performance to a new level. New Quick-CI and Smart SIM functionality reduces analysis times and running costs while front access to the ion source enables easier routine maintenance.
Features: - Smart SIM creation function – automatically creates a program that enables a staggered SIM of multiple components, resulting in higher SIM sensitivity
- Quick-CI function – allows users to introduce reagent gas while using the EI source to look for the molecular ion
- Advanced Scanning Speed Protocol – allows for the ability to scan up to 20,000 u/sec
- New turbomolecular pump achieves optimal performance with all carrier gases
- Front access to the ion source for easier, faster routine maintenance
- Simultaneous Scan/SIM for qualitative and quantitative data in a single run
- Twin-Line MS System – allows the GCMS-QP2020 NX to accept two narrow-bore capillary columns into the MS simultaneously, enabling users to switch applications without physically modifying the column installation
- Specialized databases with additional retention indices support more accurate qualitative analysis, convenient quantitative method development, and screening analysis.
Other features of the GCMS-QP2020 NX include a high-capacity differential vacuum system; high-sensitivity ion source; high-performance quadrupole mass filter; and easy sTop, which enables users to perform maintenance on the injection port without venting the MS, for drastic reduction of maintenance time.
GCMSsolution software provides intuitive control of the GCMS-QP2020 NX. Also available is LabSolutions Insight. This data review software enables faster quantitative analysis and higher productivity when analyzing pesticides, forensic toxicological substances, environmental pollutants, and many other substances. In addition, each system can be configured with a variety of sample introduction devices to address specific application requirements.... Read More | Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers faster measurements and higher detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without
Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers faster measurements and higher detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without sacrificing sensitivity or resolution
- Unsurpassed 15 msec polarity switching speed, for the most data without peak deterioration in a single injection
- Multiple Ionization options – ESI, APCI, and DUIS
- Dual Ion Source – truly enables simultaneous ESI and APCI analysis
- Easy system maintenance – enables greater uptime and usability
- Innovative ion optics—provide greater sensitivity than any other single quadrupole analyzer
- Backwards compatible – no need to upgrade your HPLC
The ESI method typically used for LCMS can be replaced with APCI, which is suitable for neutral compounds, or with a dual ionization source (DUIS) for simultaneous operation of both ionization modes, quickly and without tools. Selection of the DUIS ionization mode (ESI or APCI) can be performed via the computer. In addition, the desolvation line, where the ions enter the MS unit, can be replaced without breaking vacuum.... Read More | Shimadzu's most powerful tandem mass spectrometer, the triple quad LCMS-8060NX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity. Incorporation of a new IonFocus electrospray unit and newly designed ion guides deliver robust operation Shimadzu's most powerful tandem mass spectrometer, the triple quad LCMS-8060NX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity. Incorporation of a new IonFocus electrospray unit and newly designed ion guides deliver robust operation through reduced matrix effects and less contamination inside the instrument, resulting in maximized uptime, the utmost in data quality, and a more efficient analytical workflow.
Ion focus lenses in the state-of-the-art integrated electrospray probe propel ions into the LCMS-8060NX with the greatest of efficiency.
The heat assist design increases desolvation efficiency and promotes superior ionization of a wide range of compounds.
Unique UFsweeper technology effectively sweeps ions from the collision cell without deceleration, maintaining high-sensitivity analysis even at high acquisition speeds.
Ion guides increase robustness while maintaining high ion transmission efficiency.
Consumable parts like the ESI spray needle and the inlet desolvation line (DL) can be changed quickly and easily without breaking vacuum.
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing. The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow, including project file management, optimization of MRM and interface parameters, efficient verification of quantitative results, simple method and batch creation and verification of quantitative results.... Read More | The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of use is evident throughout the system from mass calibration to maintenance, allowing the LCMS-9050 to be used easily in any scenario that requires accurate mass spectrometry.
Key features/benefits:
- Stable long-term mass accuracy with a high-precision temperature control system that inhibits even tiny mass variations caused by external factors
- Achieves consistent mass accuracy values, even when samples are analyzed successively in both positive and negative ion modes; this significantly reduces the time required for stabilization and analysis for improved analytical throughput
- Fast, stable polarity switching through incorporation of proprietary high-precision electrical circuitry and the UFstabilization™ algorithm (patent pending)
- Ultrafast data acquisition rates
- Requires only a small sample size for identification of unknowns
- Auto-tuning function that uses a standard sample to automatically correct mass accuracy, resolution, sensitivity, and other parameters
- Easy maintenance; the desolvation line and the ESI capillary can be replaced quickly and easily without breaking vacuum, minimizing downtime
LabSolutions Insight Explore™ software manages and processes data on the LCMS-9050 system. It enables library searching, structural analysis, composition estimation, multivalent ion analysis, and quantitative analysis of target compounds. The software organizes and presents analysis results clearly in one easy-to-read screen.... Read More |