Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemThermo Scientific™ Q Exactive™ Plus Hybrid Orbitrap™ Mass SpectrometerThermo Scientific™ Exactive™ Plus EMR Orbitrap™ LC-MS SystemThermo Scientific™ ISQ™ 7610 Single Quadrupole GC-MS SystemTSQ Altis™ MD Mass SpectrometerTSQ Quantis™ MD Mass Spectrometer
Citations
Catalog NumberIQLAAEGAAPFALGMBDKIQLAAEGAAPFALGMBDLIQLAAAGAAJFALOMBNAIQLAAEGAAXFAQSMBLCIQLAAEGAAXFAQTMBLA
Price
Ionization Method(s)InquireAPCI, H-ESIEI, FS, SIM, FS/SIM, CI, PCI, NCI, depending on modelInquireInquire
Mass AnalyzerHybrid Quadrupole-Orbitrap™OrbitrapTriple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 µATriple quadrupoleTriple quadrupole
Scanning SpeedUp to 12 HzUp to 12 HzInquireInquireInquire
Mass Range50 to 6,000 m/z350 to 20,000 m/z1.2–1100 u with Unit Mass Resolution5 to 3000 m/z5 to 3000 m/z
DescriptionTake Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased ... Read MoreWhile analysis of denatured proteins may be the most common LC/MS protein analysis, many biopharmaceutical and biological research applications require analysis of proteins in their native (intact) state. The Thermo Scientific™ Exactive™ Plus EMR mass spectrometer combines unsurpassed high-... Read MoreDeveloped to enhance user experience in their workflows, the ISQ 7610 GC-MS system is streamlined to ensure great data consistency over time while offering automated instrument control tools.Achieve the sensitivity to perform routine quantitative analyses with remarkable speed and robustness. The Thermo Scientific™ TSQ Quantis™ MD Series mass spectrometer can be used by clinical diagnostic laboratories to meet their routine requirements for laboratory developed tests (LDTs). With Active... Read MoreDevelop in vitro diagnostic tests for demanding quantitative analyses leveraging the enhanced sensitivity and remarkable speed and robustness of the Thermo Scientific™ TSQ Altis™ MD Series Mass Spectrometer. The TSQ Altis MD Series mass spectrometer, a Class I medical device, offers superb ... Read More