Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemThermo Scientific™Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ LC-MS/MS Mass SpectrometerOrbitrap Astral Mass SpectrometerThermo Scientific™ ISQ™ EC Single Quadrupole Mass SpectrometerThermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass SpectrometerThermo Scientific™ TSQ™ 9610 Triple Quadrupole GC-MS/MS System
Citations
Catalog NumberIQLAAEGAAPFALGMBDKOrbitrap Astral Mass SpectrometerIQLAAAGADIFZZZMZZZIQLAAEGAAPFADBMBHQIQLAAAGABNFARPMBNB
Price
Ionization Method(s)APCI, H-ESIAdjustable heated electrospray ionization (HESI) probeAPI, HESIHESIVaries by model, AEI, EI, CI
Mass AnalyzerHybrid Quadrupole / OrbitrapOrbitrap mass analyzer ranging from 7,500 to 480,000 resolution at m/z 200
Astral mass analyzer is operated at a single resolution setting of 80,000 at m/z 524
Single quadrupoleOrbitrapTriple quadrupole
Scanning SpeedUp to 12 HzUp to 200 HzUp to 20,000 Da/sec.InquireInquire
Mass Range50 to 6,000 m/zMaximum Astral mass analyzer resolution up to 80,000 FWHM at m/z 524
Maximum Orbitrap mass analyzer resolution of up to 480,000 FWHM at m/z 200
10 to 1250 m/zm/z 50–2,000
m/z 200–4,000
up to m/z 6,000 without precursor ion selection (OTMS only)
Inquire
DescriptionTake Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased ... Read MoreInquireAdd mass spectrometry (MS) to your IC and LC analyses for access to the valuable data that only MS can provide. The new, easy-to-use Thermo Scientific™ ISQ™ EC Single Quadrupole Mass Spectrometer seamlessly integrates with ion chromatography (IC) and high performance liquid chromatography (HPLC) ... Read MoreExcel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. This... Read MoreThe TSQ 9610 GC-MS/MS system is designed to revolutionize laboratory productivity by delivering unprecedented levels of performance and reduce cost per sample for the high-throughput environment.